Page 149

Appendix C Communications Status Codes The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table C-1 lists the failures associated with the status codes. The values are additive. Table C-1. Communications Status Codes Status Code 0002

Meaning Receive overrun error

0004

Receive parity error

0008

Receive framing error

0010

Programming voltage not present

0020

Data Set Ready or Carrier Detect not detected on open

0080

ABORT key hit during comm

0100

Insufficient NVM for image

0200

Illegal Intel hexadecimal record

0400

Unsupported Intel record

0600

NVM EEPROM failed to erase

0800

Receive time-out error

1000

Control start character time-out

2000

Clear To Send inactive time-out error

4000

Receive buffer full

C-1

Page 150

Series 3100/3500 Product Reference Guide

C-2

Page 151

Appendix D Specifications Environment The terminal’s operating conditions are listed in Table D-1, Environmental Specifications. Table D-1. Environmental Specifications Condition

Note:

Range

Operating Temperature

0o o

Storage Temperature

-20o C to 60o C

Humidity (Operating)

0 to 95% (noncondensing)

Altitude

Up to 10,000 feet

C to 40 C

Batteries lose power faster at extremely high and low temperatures, and at temperatures below 0oC, the LCD operates slowly.

Storage If the terminal is not used for more than a week, store it in a cool, dry place, away from dust. Remove the battery and repack the terminal in its original shipping container. For a storage period of a few days, the batteries can remain in the terminal. If the batteries are left in the terminal for an extended period of time, data stored in the terminal may be lost. To avoid data loss, keep the NiCd batteries charged.

D-1

Page 152

Series 3100/3500 Product Reference Guide

Scanning Standard 1-D Scan Element Table D-2. Standard 1-D Scan Element Specifications Item

Description

Power Requirements

3.0 to 5.5 VDC; 60 mA typ @V cc; 70 mA max

Surge Current

60 mA typical @ 5.5 VDC; duration, 16 mSec

Cold Standby Current

50 mA

Max Vcc Noise Level

100 mV p to p

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Laser Power

.9 mW max

Skew Tolerance

± 65o from normal

Pitch Angle

± 55o from normal

Specular Dead Zone

±2o

Decode Depth of Field

Minimum element resolution is 5 mils (.127 mm) Max Typical working distance is 34 in. (86 cm)

Print Contrast Minimum

20% absolute dark/light reflectance differential, measured at 675 nm.

Ambient Light Immunity

Immune to direct exposure from normal office and factory level light

Sunlight

8000 ft. candles; 86,112 lux with correct enclosure

Artificial Light

150 ft. candles; 1615 lux

Shock

1500 G applied via any mounting surface @23o C

Vibration

Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.

Operating Temperature

-4° to 122° F; -20° to 50° C

Storage Temperature

-40° to 140° F; -40° to 60° C

Humidity

5% to 95% non-condensing

Height

0.76 in. max.; 1.93 cm

Width

1.60 in. max.; 4.1 cm

Length

1.49 in. max.; 3.8 cm

Weight

1.70 oz. max.; 48 gm

D-2

Page 153

Specifications

Long Range 1-D Scan Element Table D-3. Long Range 1-D Scan Element Specifications Item

Description

Power Requirements

3.0 to 5.5 VDC; 70 mA typ @Vcc; 95 mA max

Surge Current

120 mA typical @ 5.5 VDC; duration, 15 mSec

Max Vcc Noise Level

100 mV p to p

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Laser Power

1.45 mW max

Skew Tolerance

± 65o from normal

Pitch Angle

± 55o from normal

Specular Dead Zone

±2o

Decode Depth of Field

Minimum element resolution is 10 mils (.254 mm) Max Typical working distance is 65 in. (165 cm)

Print Contrast Minimum

50% absolute dark/light reflectance differential, measured at 675 nm.

Ambient Light Immunity

Immune to direct exposure from normal office and factory level light

Sunlight

8000 ft. candles; 86,112 lux with correct enclosure

Artificial Light

150 ft. candles; 1615 lux

Shock

1500 G applied via any mounting surface @23o C

Vibration

Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.

Operating Temperature

-4° to 122° F; -20° to 50° C

Storage Temperature

-40° to 140° F; -40° to 60° C

Humidity

5% to 95% non-condensing

Height

0.76 in. max.; 1.93 cm

Width

1.60 in. max.; 4.1 cm

Length

1.49 in. max.; 3.8 cm

Weight

1.70 oz. max.; 48 gm

D-3

Page 154

Series 3100/3500 Product Reference Guide

1-D / PDF417Scan Element Table D-4. 1-D / PDF417 Scan Element Specifications Item

Description

Power Requirements

+5 V, @ <130mA Typical

Laser Diode Power

1.2 mW, max

Scan Pattern Start Time:

0.065 sec. to 75% of steady state horizontal amplitude; 0.50 sec. to 90% of steady state vertical amplitude

Scan Angle

X = ± 18.1 degrees optical; Y = ± 6.8 degrees optical

Beam Deviation (offset from the X = 3.3 degrees; Y = 3.0 degrees. Max droop ± 1 degree. nominal) Horizontal tilt: ± 2 degrees. Pattern Geometry

At 10 in. from the chassis front, the pattern is 7.2 in. horizontally and 2.6 in. vertically. Parallelogram (deviation from the rectangular): 10o max.

Scan Rate

560 scans/sec. 280 Hz ±10 Hz (horizontal)

Frame Rate

25 frames/sec. 12.5 Hz ±1 Hz (vertical)

Optical Resolution

Can decode a 6.6 mil (minimum X-dimension) symbol (PDF417); Y-dimension must be 3X.

Max. Size of PDF417

5.0 in. wide x 2.3 in. high (928 codewords, at security level 0 - 8)

Decode Capability

1-D Symbologies: UPC-A, UPC-E, EAN-8, EAN-13, Code 39, Code 39 Full ASCII, Code 128, Interleaved 2 of 5, Codabar, UCC/EAN 128. Cannot autodiscriminate between Code 39 and Code 39 Full ASCII. 2-D Symbology: PDF417 (up to 928 codewords at security level 0 - 8).

Angular Orientation Tolerances Pitch Tolerance

± 30o (“front to back”)

Skew

± 15o from plane parallel to symbol (“side-to-side”)

Rotational Tolerance

± 4o (for scanning benchmark label, assuming 3:1 codeword aspect ratio). Note that this is dependent on the decoder.

Specular Dead Zone

± 2° (1-D symbologies) or ± 9° (PDF417) from beam direction

D-4

Page 155

Specifications

Item

Description

Print Contrast Minimum

35% absolute dark/light reflectance differential (PDF); 25% absolute dark/light reflectance differential (1-D)

Vibration

< .15 g when attached with vibration isolation; < .3 g when hard-mounted

Humidity

5% to 95% non-condensing

Shock

3 ft (91.44 cm) drop when attached to a solid surface

Ambient Light Immunity

Immune to direct exposure from normal office and factory level lighting

Sunlight

8000 ft. candles; 86,112 lux with correct enclosure

Incandescent

450 ft. candles 4845 lux

Flourescent

450 ft. candles 4845 lux

Sodium Vapor

450 ft. candles 4845 lux

Mercury

450 ft. candles 4845 lux

Operating Temperature

-4° to 122° F; -20° to 50° C (@ 100% duty cycle)

Storage Temperature

-40° to 140° F; -40° to 60° C

Humidity

5% to 95% non-condensing

Height

0.875 in. max.; 2.08 cm

Width

1.56 in. max.; 3.96 cm

Length

1.32 in. max.; 3.4 cm

Weight

1.6 oz. max.; 45 gm

D-5

Page 156

Series 3100/3500 Product Reference Guide

D-6