Page 149
Appendix C Communications Status Codes The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table C-1 lists the failures associated with the status codes. The values are additive. Table C-1. Communications Status Codes Status Code 0002
Meaning Receive overrun error
0004
Receive parity error
0008
Receive framing error
0010
Programming voltage not present
0020
Data Set Ready or Carrier Detect not detected on open
0080
ABORT key hit during comm
0100
Insufficient NVM for image
0200
Illegal Intel hexadecimal record
0400
Unsupported Intel record
0600
NVM EEPROM failed to erase
0800
Receive time-out error
1000
Control start character time-out
2000
Clear To Send inactive time-out error
4000
Receive buffer full
C-1
Page 150
Series 3100/3500 Product Reference Guide
C-2
Page 151
Appendix D Specifications Environment The terminal’s operating conditions are listed in Table D-1, Environmental Specifications. Table D-1. Environmental Specifications Condition
Note:
Range
Operating Temperature
0o o
Storage Temperature
-20o C to 60o C
Humidity (Operating)
0 to 95% (noncondensing)
Altitude
Up to 10,000 feet
C to 40 C
Batteries lose power faster at extremely high and low temperatures, and at temperatures below 0oC, the LCD operates slowly.
Storage If the terminal is not used for more than a week, store it in a cool, dry place, away from dust. Remove the battery and repack the terminal in its original shipping container. For a storage period of a few days, the batteries can remain in the terminal. If the batteries are left in the terminal for an extended period of time, data stored in the terminal may be lost. To avoid data loss, keep the NiCd batteries charged.
D-1
Page 152
Series 3100/3500 Product Reference Guide
Scanning Standard 1-D Scan Element Table D-2. Standard 1-D Scan Element Specifications Item
Description
Power Requirements
3.0 to 5.5 VDC; 60 mA typ @V cc; 70 mA max
Surge Current
60 mA typical @ 5.5 VDC; duration, 16 mSec
Cold Standby Current
50 mA
Max Vcc Noise Level
100 mV p to p
Scan Repetition Rate
36 (± 3) scans/sec (bidirectional)
Laser Power
.9 mW max
Skew Tolerance
± 65o from normal
Pitch Angle
± 55o from normal
Specular Dead Zone
±2o
Decode Depth of Field
Minimum element resolution is 5 mils (.127 mm) Max Typical working distance is 34 in. (86 cm)
Print Contrast Minimum
20% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure from normal office and factory level light
Sunlight
8000 ft. candles; 86,112 lux with correct enclosure
Artificial Light
150 ft. candles; 1615 lux
Shock
1500 G applied via any mounting surface @23o C
Vibration
Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.
Operating Temperature
-4° to 122° F; -20° to 50° C
Storage Temperature
-40° to 140° F; -40° to 60° C
Humidity
5% to 95% non-condensing
Height
0.76 in. max.; 1.93 cm
Width
1.60 in. max.; 4.1 cm
Length
1.49 in. max.; 3.8 cm
Weight
1.70 oz. max.; 48 gm
D-2
Page 153
Specifications
Long Range 1-D Scan Element Table D-3. Long Range 1-D Scan Element Specifications Item
Description
Power Requirements
3.0 to 5.5 VDC; 70 mA typ @Vcc; 95 mA max
Surge Current
120 mA typical @ 5.5 VDC; duration, 15 mSec
Max Vcc Noise Level
100 mV p to p
Scan Repetition Rate
36 (± 3) scans/sec (bidirectional)
Laser Power
1.45 mW max
Skew Tolerance
± 65o from normal
Pitch Angle
± 55o from normal
Specular Dead Zone
±2o
Decode Depth of Field
Minimum element resolution is 10 mils (.254 mm) Max Typical working distance is 65 in. (165 cm)
Print Contrast Minimum
50% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure from normal office and factory level light
Sunlight
8000 ft. candles; 86,112 lux with correct enclosure
Artificial Light
150 ft. candles; 1615 lux
Shock
1500 G applied via any mounting surface @23o C
Vibration
Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.
Operating Temperature
-4° to 122° F; -20° to 50° C
Storage Temperature
-40° to 140° F; -40° to 60° C
Humidity
5% to 95% non-condensing
Height
0.76 in. max.; 1.93 cm
Width
1.60 in. max.; 4.1 cm
Length
1.49 in. max.; 3.8 cm
Weight
1.70 oz. max.; 48 gm
D-3
Page 154
Series 3100/3500 Product Reference Guide
1-D / PDF417Scan Element Table D-4. 1-D / PDF417 Scan Element Specifications Item
Description
Power Requirements
+5 V, @ <130mA Typical
Laser Diode Power
1.2 mW, max
Scan Pattern Start Time:
0.065 sec. to 75% of steady state horizontal amplitude; 0.50 sec. to 90% of steady state vertical amplitude
Scan Angle
X = ± 18.1 degrees optical; Y = ± 6.8 degrees optical
Beam Deviation (offset from the X = 3.3 degrees; Y = 3.0 degrees. Max droop ± 1 degree. nominal) Horizontal tilt: ± 2 degrees. Pattern Geometry
At 10 in. from the chassis front, the pattern is 7.2 in. horizontally and 2.6 in. vertically. Parallelogram (deviation from the rectangular): 10o max.
Scan Rate
560 scans/sec. 280 Hz ±10 Hz (horizontal)
Frame Rate
25 frames/sec. 12.5 Hz ±1 Hz (vertical)
Optical Resolution
Can decode a 6.6 mil (minimum X-dimension) symbol (PDF417); Y-dimension must be 3X.
Max. Size of PDF417
5.0 in. wide x 2.3 in. high (928 codewords, at security level 0 - 8)
Decode Capability
1-D Symbologies: UPC-A, UPC-E, EAN-8, EAN-13, Code 39, Code 39 Full ASCII, Code 128, Interleaved 2 of 5, Codabar, UCC/EAN 128. Cannot autodiscriminate between Code 39 and Code 39 Full ASCII. 2-D Symbology: PDF417 (up to 928 codewords at security level 0 - 8).
Angular Orientation Tolerances Pitch Tolerance
± 30o (“front to back”)
Skew
± 15o from plane parallel to symbol (“side-to-side”)
Rotational Tolerance
± 4o (for scanning benchmark label, assuming 3:1 codeword aspect ratio). Note that this is dependent on the decoder.
Specular Dead Zone
± 2° (1-D symbologies) or ± 9° (PDF417) from beam direction
D-4
Page 155
Specifications
Item
Description
Print Contrast Minimum
35% absolute dark/light reflectance differential (PDF); 25% absolute dark/light reflectance differential (1-D)
Vibration
< .15 g when attached with vibration isolation; < .3 g when hard-mounted
Humidity
5% to 95% non-condensing
Shock
3 ft (91.44 cm) drop when attached to a solid surface
Ambient Light Immunity
Immune to direct exposure from normal office and factory level lighting
Sunlight
8000 ft. candles; 86,112 lux with correct enclosure
Incandescent
450 ft. candles 4845 lux
Flourescent
450 ft. candles 4845 lux
Sodium Vapor
450 ft. candles 4845 lux
Mercury
450 ft. candles 4845 lux
Operating Temperature
-4° to 122° F; -20° to 50° C (@ 100% duty cycle)
Storage Temperature
-40° to 140° F; -40° to 60° C
Humidity
5% to 95% non-condensing
Height
0.875 in. max.; 2.08 cm
Width
1.56 in. max.; 3.96 cm
Length
1.32 in. max.; 3.4 cm
Weight
1.6 oz. max.; 45 gm
D-5
Page 156
Series 3100/3500 Product Reference Guide
D-6