The text of a manual · part 12 of 18
Series 3100/3500 Product Reference Guide: Chapter 6 Maintaining the 3100/3500 Terminal
Pages 101 to 114 of 170, from Series 3100/3500 Product Reference Guide
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol PDT-3100, Symbol PDT-3110, Symbol PDT-3140, Symbol PDT-3500, Symbol PDT-3510 and Symbol PDT-3540
Page 101
Chapter 6 Maintaining the 3100/3500 Terminal Chapter Contents Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 When to Replace or Recharge Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 Replacement Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Alkaline (PDT 3100). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Replacing NiCd or NiMH (PDT 3100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 Replacing NiCd or NiMH Batteries (PDT 3500) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10 NiCd or NiMH Battery Charging (PDT 3100 and PDT 3500) . . . . . . . . . . . . . . . . . . . . . . . 6-12 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14
6-1
Page 102
Series 3100/3500 Product Reference Guide
6-2
Page 103
Maintaining the 3100/3500 Terminal
Batteries The Series 3100 terminal’s primary power is provided by a 9-Volt alkaline battery, a rechargeable nickel cadmium (NiCd), or nickel metal hydride (NiMH) battery pack. The PDT 3500 is powered by a single battery pack, which may be NiCd or NiMH.
Battery Life Many factors affect battery pack life, including temperature, battery age, and data collection method. Uses and operating conditions which affect battery life are: • scanning
• “power save” mode
• radio communications
• backlighting use
• very high operating temperatures
• very low operating temperatures
The approximate battery life between charges (NiCd, NiMH) or replacement (alkaline) is summarized inTables 6-1, 6-2, and 6-3. Note that these values vary with the application. Applications involving modem and radio communications shorten these times. Table 6-1. Battery Life: PDT 31X0 Battery Type 9V Alkaline
400 MaH NiCd
600 MaH NiMH
Input Method
Approx. Operating Time: PDT 3100
Approx. Operating Time: PDT 3110
Keyboard
30 hours x
Laser Scanner
4500 + scans x
Wand Scanner
5000 + scans
Keyboard
40 hours x 35 hours
Laser Scanner
4300 + scans
4000 + scans
Wand Scanner
4300 + scans
4000 + scans
Keyboard
50 hours
45 hours
Laser Scanner
6400 + scans
6100 + scans
Wand Scanner
6400 + scans
6100 + scans
* Power consumption is highly application-dependent. The figures above represent battery life of typical applications. However, battery life with individual applications will vary.
Note:
Alkaline batteries are NOT recommended for use with the PDT 3110 or 3140.
6-3
Page 104
Series 3100/3500 Product Reference Guide
Table 6-2. Battery Life: PDT 35X0, 1-D Battery Type 800 MaH NiCd
1200 MaH NiMH
Input Method Keyboard
Approx. Operating Time: PDT 3500S
Approx. Operating Time: PDT 3510S
65 hours
55 hours
Laser Scanner
6800 + scans
6400 + scans
Wand Scanner
6800 + scans
6400 + scans
Keyboard
80 hours
70 hours
Laser Scanner
10,000 + scans
9500 + scans
Wand Scanner
10,000 + scans
9500 + scans
* Power consumption is highly application-dependent. The figures above represent battery life of typical applications. However, battery life with individual applications will vary.
Note:
Alkaline batteries are NOT recommended for use with the PDT 3510 or 3540. Table 6-3. Battery Life: PDT 35X0, 2-D
Battery Type 800 MaH NiCd
1200 MaH NiMH
Approx. Operating Time: PDT 3500P
Approx. Operating Time: PDT 3510P, PDT 3540-P
Keyboard
44 hours
36 hours
Laser Scanner
2500 + scans
2400 + scans
Input Method
Wand Scanner
2500 + scans
2400 + scans
Keyboard
56 hours
48 hours
Laser Scanner
3700 + scans
3600 + scans
Wand Scanner
3700 + scans
3600 + scans
* Power consumption is highly application-dependent. The figures above represent battery life of typical applications. However, battery life with individual applications will vary.
6-4
Page 105
Maintaining the 3100/3500 Terminal
When to Replace or Recharge Batteries The Series 3100 and 3500 provide two types of indicators to notify you when battery power is running low: warning messages and modified cursors. These indicators may be changed or disabled by an application program. • LOW POWER, When the battery is low, the cursor changes as shown inTable 6-4. If ERR3000 is loaded, the message LOW BATTERY also appears. At this level, the terminal continues to operate, but there is probably less than 1 hour of usable power left. Note:
When the LOW BATTERY message is displayed on PDT 3500 terminals, the 2D scanner will not scan until the battery is recharged or replaced.
• VERY LOW, When the power is very low, the REPLACE BATTERY message appears and the system powers off. Replace or recharge the battery before attempting to use the terminal. If the battery is not immediately recharged or replaced, data may be lost. Battery life varies between 500 - 1000 charge / recharge cycles. This variation depends on the depth of discharge. In general, replace batteries which exhibit less than 80% of their total rated capacity. Table 6-4. Cursor Indicators
Keyboard State
Cursor Character
Low Battery
6-5
Page 106
Series 3100/3500 Product Reference Guide
Supercap Power Backup To prevent data loss during battery replacement, the terminals have a supercap power backup. The supercap backup provides sufficient power to preserve memory contents for approximately 5 minutes while batteries are replaced. The supercap does not provide enough power to operate the terminal. On receiving a low battery message, replace or recharge the primary batteries immediately.
Replacement Batteries For PDT 31X0 Rechargeable battery packs are available from Symbol Technologies: • NiCd battery pack, 400 MaH, KT-12596-01 • NiMH battery pack, 600 MaH, KT-12596-02 9-Volt alkaline batteries vary slightly in size and some may not make a good electrical contact. The following batteries are known to be the proper size and are assured to work: • Eveready #522 • Duracell #MN1604 and #MN1604-AS, or equivalent
For PDT 35X0 Rechargeable battery packs are available from Symbol Technologies: • NiCd battery pack, 800 MaH, 21-14969-01 • NiMH battery pack, 1200 MaH, 21-14969-02
6-6
Page 107
Maintaining the 3100/3500 Terminal
Battery Replacement Alkaline (PDT 3100) To replace the 9V alkaline battery (refer to Figure 6-1): 1.
Turn terminal off.
2.
Release hand strap.
3.
Unlock and remove battery compartment door.
PART NO.: 3100-9M0L050 S/N: B029721 SYMBOL TECH, INC.
PART NO.: 3100-9M0L050 S/N: B029721 SYMBOL TECH, INC.
Figure 6-1. Opening the PDT 3100 Battery Compartment 4.
Detach the battery from the 9V connector, and remove it from the compartment.
Caution Dispose of dead batteries in accordance with battery label instructions. 5.
Snap the replacement 9V alkaline battery to the connector and place it in the battery compartment.
6-7
Page 108
Series 3100/3500 Product Reference Guide
6.
Replace the battery compartment cover and reattach the hand strap. Note:
The following batteries are recommended for a good electrical contact: Eveready #522, Duracell #MN1604, or Duracell #MN1604-AS alkaline batteries.
To replace a NiCd or NiMH battery with an 9V alkaline battery: 1.
Perform steps 1-3 above.
2.
Remove the NiCd or NiMH battery and NiCd or NiMH battery connector.
3.
Plug the 9V connector in the 9V socket (refer to Figure 6-2).
4.
Perform steps 5-6 above.
6-8
Page 109
Maintaining the 3100/3500 Terminal
Replacing NiCd or NiMH Batteries (PDT 3100) To replace an alkaline battery with a rechargeable NiCd or NiMH battery pack, or to replace a NiCd or NiMH battery pack: 1.
Power the terminal off.
2.
Release the hand strap.
3.
Unlock and remove the battery compartment door.
4.
If the previous battery was an alkaline, gently remove the 9V connector fromthe 9V socket. Do NOT tug on connector wires. Store the connector.
5.
Plug the battery connector in the rechargeable battery socket immediately below the 9V socket (refer to Figure 6-2).
6.
Fit the NiCd or NiMH battery pack in the compartment next to the adapter.
7.
Verify that the battery and connector are properly seated.
NiCd Battery Battery Connector
Handstrap Hold Plugs Battery Sockets
PART NO.: 3100-9M0L050 S/N: B029721 SYMBOL TECH, INC.
Battery Compartment Latch
Handstrap Connector
Battery Compartment Door
Figure 6-2. PDT 3100 Battery Replacement 8.
Replace and lock the battery compartment cover.
9.
Reattach the hand strap.
10. Recharge the battery pack (refer to NiCd or NiMH Battery Recharging).
6-9
Page 110
Series 3100/3500 Product Reference Guide
Replacing NiCd or NiMH Batteries (PDT 3500) For the PDT 3500, each type of battery uses a battery pack of the same physical form. Installation and replacement are the same for all battery types.
To Remove a PDT 3500 Battery Pack: 1.
Power the terminal off.
2.
Release the hand strap.
3.
Grasp the tab (shown in Figure 6-3) at the top of the battery pack and pull back.
4.
Lift the battery up from the compartment, tabbed edge first. Tab
Battery Pack
Figure 6-3. PDT 3500 Battery Pack Removal 5.
If it is rechargeable, recharge the old battery pack. Refer toNiCd or NiMH Battery Charging (PDT 3100 and PDT 3500).
Caution Dispose of dead batteries in accordance with battery label instructions.
6-10
Page 111
Maintaining the 3100/3500 Terminal
To Install a New or Recharged Battery Pack:
Battery Compartment
Spaces for Posts
Battery Pack
Posts
Figure 6-4. PDT 3500 Battery Pack Replacement 1.
Insert the battery in the bottom of the compartment. Two posts on the battery pack must fit in corresponding spaces in the housing (refer to Figure 6-4).
2.
Push the battery pack forward until it lies flat in the compartment, flush with the housing. When it lies in this position, the lift tab should snap in and the contacts should meet.
3.
Reattach the hand strap.
6-11
Page 112
Series 3100/3500 Product Reference Guide
NiCd or NiMH Battery Charging (PDT 3100 and PDT 3500) Cradle To charge a NiCd or NiMH battery using the one- or four-slot cradle: 1.
Plug power connector in cradle’s power socket.
2.
Plug the wall cube in wall socket (refer to Figure 6-5).
3.
Place terminal in cradle.
4.
Verify that terminal is properly seated.
5.
If the battery power is very low, press <PWR> to initiate charging. Depending on the type, the battery pack fully charges in approximately 1.5 to 2 hours (PDT 3100) or 3 to 5 hours (PDT 3500).
Figure 6-5. One-Slot Cradle Setup for Charging
Battery Charging Tips For maximum capacity and battery life: • Charge at temperatures between 0oC and 45oC (32oF and 113oF). Optimum charging occurs at room temperature (about 20oC to 25oC). Above or below that range, batteries may not charge to rated capacity. • Recharge as soon as you see the "Low Battery" message. • Charge NiCd or NiMH batteries after storage.
6-12
Page 113
Maintaining the 3100/3500 Terminal
3115 Communications/Charger Adapter (PDT 3100 and KT-12596-01 Only) The optional 3115 Communications/Charger Adapter (CCA) provides power from a wall-mounted power supply for recharging the NiCd battery while the terminal is in use. To charge the terminal using the 3115 CCA (refer to Figure 6-6): 1.
Plug the 10-pin RJ41 connector in the terminal base.
2.
Plug the connector from the 15V power supply, P/N 59915-00-00 (US, 115V) or 60507-00-00 (International, 230V) in the CCA’s power input jack.
3.
Plug the power supply in a wall socket.
RJ41 3115 CCA
DB25
Power Input Jack
Figure 6-6. Connections for Charging with the 3115 CCA (PDT 3100 ONLY) NiCd batteries recharge fully in 12 to 16 hours. Note:
For the PDT 3100, you may only charge the battery KT12596-01 in the terminal through the 3115 CCA.
Other Charging Options Note that you can charge the KT-12596-01 battery pack using the Universal Four-Slot Charger (3004-xxx) or the UBC 1000 Charger. Use the UBC 1000 Charger to charge the KT-12596-01, 21-14969-01, and 21-14969-02 battery packs.
6-13
Page 114
Series 3100/3500 Product Reference Guide
Cleaning Series 3100 and 3500 terminals require a minimum amount of maintenance. However, keep the terminal clean to avoid problems and prolong the terminal’s life. To clean a terminal, use a clean, soft cloth dampened with a mild cleaner such as soap and water. Do not use abrasive paper, cloth, or abrasive/corrosive cleaners. Wipe the entire terminal, except for the scanner window, with the damp cloth. Clean the keypad and scanner triggers. Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.
Caution Do not pour, spray, or spill any liquid onto any part of the terminals, particularly the scanner or scan element components.
6-14