Page 63

System Mode

Connector Parameters To set the communications parameters for the direct-connect interface: 1. Select 2:CONNECTOR on the SET COM menu. The following screen displays:

SET CONNECTOR 1:TRANSMIT SPEED 2:PARITY BIT 3:DATA BIT 4:STOP BIT 5:PROTOCOL

2. Select one of the following options using the numeric keys or F5 and F6 keys. Note: If the IR protocol is selected, the parity bit, character length, and stop bit length settings are ignored. a. Select 1:TRANSMIT SPEED to display the transmission speed screen. Select the transmission speed using the numeric keys or F5 and F6 keys. b. Select 2:PARITY BIT for the parity screen. Select the parity (none, odd or even) using the numeric keys or F5 and F6 keys. c. Select 3:DATA BIT to display the character length screen. Select the character length using the numeric keys or F5 and F6 keys. d. Select 4:STOP BIT to set stop bits. Select the stop bit length using the numeric keys or F5 and F6 keys. e. Select 5:PROTOCOL to set communications protocol. Select a screen using the numeric keys or F5 and F6 keys, then press ENT. Note: If the IR protocol is selected, the serial number and horizontal parity settings are ignored. •

Select 1:SERIAL NO. on the SET PROTOCOL menu to determine whether the system should add serial numbers to data blocks. Use the numeric keys or F5 and F6 keys to select 1:ON or 2:OFF, then press the ENT key. To return to the Set Protocol menu, press the C key.

•

Select 2:H.PARITY to select whether the system should add a horizontal parity. Select 1:ON or 2: OFF, then press ENT. To return to the Set Protocol menu, press the C key. 4-19

Page 64

PDT 1100 Terminal Product Reference Guide

•

Select the 3:LINKUP TIME to select the timeout length (in seconds) to be applied when a link is to be established. Select 1:ON or 2: OFF, then press ENT. To return to the SET PROTOCOL menu, press the C key.

•

Select the 4:FIELD SPACE to select whether space codes in the tail of a data field should be ignored or handled as data. Select 1:Ignore or 2: Data, then press ENT. To return to the SET PROTOCOL menu, press the C key.

Com Port Parameters To set the interface port: 1. Select 3:COM PORT on the SET COM menu. The following screen displays. SET COM PORT 1: BASIC

OPT IFC 2: SYSTEM

OPT IFC

2. Select one of the following: •

Press 1 to select the optical or direct-connect interface port used for user programs written in BASIC 3.0 Interpreter (OPEN “COM:” or XFILE statement).

•

Press 2 to select the optical or direct-connect interface port used for downloading or uploading files in System Mode.

3. Press ENT, or C to return to the Set Connector screen.

Protocol Type Setting To set the communications protocol type: 1. Select the 4:PROTOCOL TYPE on the SET COM menu. The following screen displays: PROTOCOL TYPE 1: PROTOCOL 2: IRPROTOCOL

4-20

Page 65

System Mode

2. Select one of the following: •

Press 1 to select the protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BASIC 3.0 Interpreter. Select this protocol for file transmission with Transfer Utility.

•

Press 2 to select the IR protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BASIC 3.0 Interpreter. Select this protocol for file transmission with IR-Transfer Utility C/IR-Transfer Utility E.

3. If you selected 2: IRProtocol, the following screen displays: SET ID

00001 >>_

4. Enter the ID number of the PDT 1100 using the numeric keys, then press ENT, or just press ENT to retain the current setting. SET ID

00001 >>_65535

Note: An ID number is a five-digit decimal character string ranging from 00001 to 65535. You cannot enter a value less than five digits. If you make a wrong entry, press the BS key to delete it then enter the correct data. Press the C key until you return to the Main Menu.

4-21

Page 66

PDT 1100 Terminal Product Reference Guide

Setting the Shift Key and M Keys To define the function of the Shift key and the M keys: 1. Select the 7:KEY on the Set System menu. The following screen displays: SET KEY 1: SHIFT KEY 2: M1 KEY 3: M2 KEY 4: M3 KEY 5: M4 KEY

2. Select a key to define. a. Press 1 to switch to the shift key definition screen. •

Select NONLOCK to shift the keypad only when the SF key is held down.

•

Select ONETIME to shift only the first key pressed after the SF key. The following keys are not shifted.

•

Press 2 through 5 to set the key functions. The following screen displays (M1 key is shown here): SET M1 Key 1: Trigger switch 2: Shift Key 3: Enter Key 4: Backlight Key 5: None

•

Select Trigger Switch to assign the M key as the trigger switch.

•

Select Shift Key to assign the M key as the SF key.

•

Select Enter Key to assign the M key as the ENT key.

•

Select Backlight Key to assign the M key as the backlight function on/off key.

•

Select None to ignore the key entry.

b. Press ENT to enter your selection, or C to return to the Set System menu. Note: All M keys are assigned the trigger function by default. In user programs, a string data can also be assigned to these M keys. The backlight function on/off key can be assigned to only one of the 4-22

Page 67

System Mode

M1 through M4 keys. The last key defined acts as the backlight function on/off key and one defined earlier is ignored.

Testing The PDT 1100 terminal conducts tests of all systems upon initialization. To perform a system test: 1. Select 5:TEST on the system menu. SYSTEM MENU 1:EXEC PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VER

The following screen displays: TEST 1:BAR CODE 6:LCD 2:MEMORY 7:KEY 3:BEEPER 8:FILE 4:AGING 5:COMMUNICATIONS

2. Select a test to run: •

Press 1: BAR CODE to select the bar code reading test.

•

Press 2:MEMORY to select RAM read/write test.

•

Press 3:BEEPER to select the beeper scale test.

•

Press 4:AGING to select the aging test.

•

Press 5:COMMUNICATIONS to select the communications test.

•

Press 6:LCD to select the LCD and reading confirmation LED tests.

•

Press 7:KEY to select the key entry, beeper and vibrator tests.

•

Press 8:FILE to select the file checksum test.

3. Press ENT to enter your selection, or the C key to return to the System Menu.

4-23

Page 68

PDT 1100 Terminal Product Reference Guide

Note: If an error occurs in any of the above tests, contact your nearest Symbol Support Center. See Symbol Support Center on page -ix for more information. The following sections explain each test.

Bar Code Reading Test If you selected 1: BAR CODE on the TEST menu, scan a bar code with the PDT 1100 and check the data displayed on the LCD.

TEST BAR CODE

Number of digits in bar

A 13 4999999999999

Bar code type Data

The PDT 1100 beeps, the decode LED turns green, and the data displays with the bar code type and the number of data digits. Up to 64 digits of data are displayed; the excess is discarded. The following table defines the bar code type ID letter displayed on the screen. Table 4-5. Bar Code Type Identifiers

4-24

Bar Code Type

ID Letters

EAN-13, UPC-A

A

EAN-8

B

UPC-E

C

Standard 2 of 5 (STF)

H

Interleaved 2 of 5 (ITF)*

I

CODABAR (NW7)

N

Page 69

System Mode

CODE39

M

CODE93

L

CODE128

K

EAN-128

W

* The PDT 1100 can only read ITF bar codes with 4 digits or more in length.

Memory Test If you selected 2:MEMORY on the TEST menu, the following screen displays, then writes and reads onto/from all areas of RAM and checks the address. TEST MEMORY ** Testing ** XXXXX/YYYYY

Where: XXXXX = Tested RAM capacity (unit: kilobytes) YYYYY = Total RAM capacity (unit: kilobytes) If an error is detected, the PDT 1100 beeps three times, displays the following screen, and terminates the test.

TEST MEMORY ** Test NG** XXXXX/YYYYY ADDRESS:ZZZZZZ WRITE:AA READ:BB

Where: ZZZZZZ = Address where an error has occurred

4-25

Page 70

PDT 1100 Terminal Product Reference Guide

AA = Data to write BB = Data read out from RAM After a successful RAM test, the PDT 1100 beeps once, displays a confirmation message, and returns to the TEST menu.

Beeper Scale Test If you select 3:BEEPER on the TEST menu, the beeper sounds at three octaves as follows. Table 4-6. Beeper Scale and Frequency Scale

Frequency (Hz)

do

523

1046

2093

4186 re

587

1174

2349

- mi

659

1318

2637

- fa

698

1396

2793

- sol

783

1567

3135

- la

880

1760

3520

- ti

987

1975

3951

-

When the test is complete, the PDT 1100 returns to the TEST menu. To stop this test while in progress, turn the power off, then on.

Aging Test If you select 4:AGING on the TEST menu, choose the aging test while the current date and time is displayed on the LCD. (This test is intended for personnel who check the PDT 1100 in the factory.) TEST AGING DATE 98/00/00

Time 00:00:00

4-26

Page 71

System Mode

Note: Selecting this test disables the powering-off function. Be sure to turn the power off or press the C key to return to the TEST menu.

Communications Test Before testing the optical interface, arrange two PDT 1100s, one as a master station and the other as a slave station (to be tested) with their IR ports facing each other as illustrated in Figure 4-2. In this test, the slave PDT 1100 transmits data to the master PDT 1100 and receives the data sent back from the master PDT 1100. Data

Master terminal

2.6 feet (0.8 m)

Slave terminal

Figure 4-2. PDT 1100 Master/Slave Setup Before testing the direct-connect interface, arrange the 3-pole mini stereo plug as illustrated below and connect it to the direct-connect interface port on the PDT 1100. SD RD

Select 5:COMMUNICATIONS on the TEST menu to select an interface test. •

Press 1:OPTICAL to switch to the MASTER/ SLAVE selection screen for the optical interface test.

•

Press 2:CONNECTOR to test the direct-connect interface port.

To select the optical interface test: 1. Select 1:OPTICAL on the TEST COM menu. 2. At the slave PDT 1100 to be tested, select 1:SLAVE and at the master PDT 1100, select 2:MASTER. During the test, the screen indicates the test is running.

4-27