Page 54

PDT 1100 Terminal Product Reference Guide

Table 4-2. Upload Error Problems and Solutions Error Message

Problem

Solution

File Error!

The file you To upload the damaged file as is, press the 1 key. attempted to upload is Press the 2 key to abort the file upload. damaged.

XXXXXXX.XXX Communication error!

Uploading has failed. To retry uploading, press the 1 key. To return to the SYSTEM MENU, press the 2 key. Check the interface port and communications parameters in the SET SYSTEM menu or perform the communications test in the TEST menu. Also check the communications parameters setup of the host computer.

System Environment Setting To change system settings: 1. Select "4: SET SYSTEM" on the System Menu. SYSTEM MENU 1:EXEC PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VER

The following screen displays: SET SYSTEM 1: PROGRAM 2: DISPLAY 3: DATE/ TIME 4:BARCODE

6: COM 7: KEY

2. Select an item from the Set System menu. •

4-10

Press 1 to set an execution program that runs when the terminal powers on.

Page 55

System Mode

•

Press 2 to set the message version, display font size (standard or small), and system status indication (shift-key icon).

•

Press 3 to set the calendar clock (date and time).

•

Press 4 to set scanning parameters (black-and-white inverted label reading and the decoding level) and the minimum number of digits to read for bar codes (ITF, STF and Codabar).

•

Press 5 to set the resume function.

•

Press 6 to set the communications options (interface port and communications parameters).

•

Press 7 to define the functions of the shift key and the M keys.

Setting an Execution Program To select an execution program: 1. Select "1: PROGRAM" on the SET SYSTEM menu. The following screen displays: SET EXEC PROGRAM A:EASYPACKPD33 A:SAMPLE1.PD3 A:SAMPLE2.PD3 B:SAMPLE3.PD3 B:SAMPLE4.PD3

2. Select an execution program to run when power is applied to the terminal. The files in RAM display as "A:FILE NAME;" the flash-ROM files are "B:FILE NAME." If no program files are stored in memory, the following screen appears. SET EXEC PROGRAM ******************* NO FILE EXISTS *******************

3. Press ENT to enter your selection or C to return to the Set System menu.

4-11

Page 56

PDT 1100 Terminal Product Reference Guide

Setting Font Size and System Status Indication To select the display font size and to turn the system status indicator on or off: 1. Select "2: DISPLAY" on the Set System menu. A screen displays indicating the font size and whether the system status is ON or OFF. 2. Select an item. •

Press 1 to change the display font size used in application programs to the standard (8-dot) or small (6-dot).

•

Press 2 to turn the system status indication on or off. If it is set to on, the shiftkey icon appears.

3. Use the F7 and F8 keys and select a font/status setting. Note: You may also turn the system status indication on or off using the OUT statement in user programs. Refer to the PDT 1100 Terminal Programmer’s Guide. Selecting ON for System Status displays the SF icon, which indicates the keys on the keypad are shifted.

Setting the Calendar Clock To set the calendar clock: 1. Select 3: DATE/TIME on the Set System menu and press the ENT key. SET SYSTEM 1:PROGRAM 6:COM 2:DISPLAY 7:KEY 3:DATE/TIME 4:BARCODE 5:RESUME

The following screen appears. SET DATE/TIME 00/01/01 00:00 _ / /:

4-12

Page 57

System Mode

2. Use the numeric keys to enter the year (only the last two digits), month, day, hour (in 24-hour format), and minute in this order. Add a 0 (zero) preceding one-digit entries. For example, to set the date to July 19, 1998 and the time to 4:00pm, press 9, 8, 0, 7, 1, 9, 1, 6, 0, and 0.

SET DATE/TIME 00/01/01 00:00 98/07/19 16:00_

If you make a wrong entry, press the BS key to delete it, then enter the correct data. 3. Press ENT to enter the setting or the C key to return to the Set System screen. Settings are accepted only if all fields are completed.

Setting Bar Code Scanning Parameters The 4:BARCODE option on the Set System menu is used to set the following options:

Inverted Label Reading This black-and-white inverted label reading function (INVERT) enables the PDT 1100 to read white bars on a black background. Activating this function may increase the frequency of scanning errors.

Decode Level Decode level (DECODE LEVEL) can be set to a value from 1-9. Decreasing this value increases bar code scanning efficiency, but also increases the risk of misreading lowquality or damaged bar codes. Increasing this value decreases scanning efficiency, but it eliminates almost all possibilities of misreading. The default is 4.

Minimum Digits Minimum number of digits to be read for ITF, STF, or CODABAR (MINIMUM DIGITS) can be set to 2-20 for ITF, 1-20 for STF, or 3-20 for Codabar. Setting a small number increases the frequency of digit-missing scanning or misreading of poor quality bar codes. Setting a large number eliminates almost all possibilities of error. The default is 4 for ITF and Codabar, and 2 for STF.

4-13

Page 58

PDT 1100 Terminal Product Reference Guide

To set bar code scanning parameters: 1. Select 4: BAR CODE on the Set System menu to display the following screen: SET BAR CODE 1:INVERT ON OFF 2:DECODE LEVEL 4 MINUMUM DIGITS 3:ITF 4 4:STF 2 5: CODABAR 4

2. Select one of the following: •

Press 1 to activate or deactivate the black-and-white inverted label reading function.

•

Press 2 to set the decode level

•

Press 3 to set the minimum number of digits for ITF

•

Press 4 to set the minimum number of digits for STF

•

Press 5 to set the minimum number of digits for Codabar.

3. Select a desired setting using the F7 and F8 keys. •

To increase the decode level, press the F8 key; to decrease it, press the F7 key

•

To increase the number of digits to be read for ITF, STF and CODABAR, press the F8 key; to decrease it, press the F7 key.

4. Press the ENT key. To return to the Set System menu, press the C key.

Setting the Resume Function The resume function resumes the display shown before power off, when the terminal is powered up. To set the resume function: 1. Select 5: RESUME on the Set System menu. The following screen displays: SET RESUME

1: ON 2: OFF

4-14

Page 59

System Mode

2. Select one of the following: •

Press 1 to activate the resume function which resumes the display shown

•

Press 2 to deactivate the resume function.

3. Press ENT to enter your selection, or C to return to the Set System menu.

Setting Communications Environments After the PDT 1100 is initialized, the interface port and communications parameters are set as listed in the default tables below. Do not access them unless necessary. Table 4-3. Interface Port Parameters Default Parameter

Default

Interface Port

OPT (Optical interface port)

Communications protocol protocol

Communications parameters for the optical interface port TRANSMIT SPEED

9600 bps

PULSE WIDTH (Output pulse width of IR beam)

1.63 ms

PROTOCOL (Protocol options)

SERIAL No. ON: Adds serial numbers to data blocks. Adds a horizontal parity. LINKUP TIME: 30 seconds FIELD SPACE: Ignore

Table 4-4. Comm. Parameter Default for Direct-Connect Interface Communications Parameters

Defaults

TRANSMIT SPEED

19200 bps

PARITY BIT

None

DATA BIT (Character length)

8 bits

STOP BIT

1 bit

4-15

Page 60

PDT 1100 Terminal Product Reference Guide

Table 4-4. Comm. Parameter Default for Direct-Connect Interface (Continued) Communications Parameters PROTOCOL (Protocol options)

Defaults Adds serial numbers to data blocks. H. PARITY ON: Adds a horizontal parity. LINKUP TIME: 30 seconds FIELD SPACE: Ignore

To change communication environments: 1. Select the 6: COM on the Set System menu. The following screen displays:

SET COM 1:OPTICAL 2:CONNECTOR 3:COM PORT 4:PROTOCOL TYPE

2. Select one of the following: •

Press 1 to select the communications parameters setting screen for the optical interface.

•

Press 2 to select the communications parameters setting screen for the directconnect interface.

•

Press 3 to select the interface port setting screen.

•

Press 4 to select the communications protocol type setting screen.

3. Press ENT to enter your selection, or C to return to the Set System menu. The following sections provide instructions for setting each of these options.

4-16

Page 61

System Mode

Optical Parameters To set communications parameters for the optical interface: 1. Select 1:OPTICAL on the SET COM menu. The following screen displays: SET OPTICAL 1:TRANSMIT SPEED 2:PULSE WIDTH 3:PROTOCOL

2. Select each of the following: a. Press 1 to select the transmission speed. The following screen displays: SET SPEED <OPTICAL>

1: 2400 4: 38400 2: 9600 5: 57600 3:19200 6: 115200 b. Select the transmission speed using the numeric keys or F5 and F6 keys. Press ENT to enter your selection, or C to return to the Set Com menu. c. Press 2 to select the IR beam output pulse width. The following screen displays: SET PULSE WIDTH <OPTICAL>

1: 1.63us 2:3/16 Bit Time d. Select the pulse width using the numeric keys or F5 and F6 keys. Press ENT to enter your selection, or C to return to the SET OPTICAL screen.

4-17

Page 62

PDT 1100 Terminal Product Reference Guide e. Press 3 to select the communications protocol option. The following screen displays:

SET PROTOCOL <OPTICAL> 1:SERIAL NO. 2:H.PARITY 3:LINKUP TIME 4:FIELD SPACE f. Select one of the following using the numeric keys or F5 and F6 keys. Note: If the IR protocol is selected, the serial number and horizontal parity settings are ignored. •

Select 1:SERIAL NO. on the SET PROTOCOL menu to select whether to add serial numbers to data blocks.

•

Select 2:H.PARITY on the SET PROTOCOL menu to select whether to add a horizontal parity.

•

Select 3:LINKUP TIME on the SET PROTOCOL menu to select the timeout length (in seconds) to be applied when a link is to be established.

•

Select 4:FIELD SPACE on the SET PROTOCOL menu to select whether space codes in the tail of a data field should be ignored or handled as data.

g. Press ENT to enter your selection, or C to return to the Set Optical screen.