Page 97

Appendix A Specifications PDT 1100 Terminal Specifications The PDT 1100 terminal product specifications are as follows: Table A-1. Terminal Specifications CPU

16-bit CMOS microprocessor

Memory

Flash ROM: 512 KB (including system area); RAM: 512 KB

Application Development

Proprietary Basic Compiler

Display

Dot Matrix, liquid crystal display (LCD)

Decode Capability

UPC/EAN, Code 39, Code 93, Interleaved 2 of 5, Discrete 2 of 5, USS128, Codabar, UCC/EAN 128, ISBT- 128, Trioptic Code 39

Decode Range

Maximum distance of 22 inches (56 cm) from the bar code reading window

Dimensions

5.3” H x 2.3” W x 1.2” L (135 mm H x 59mm W x 30 mm L)

Weight

5.7 oz (160 gm)

Keyboard

24 keys including power key and four M keys

Communications

Optical interface: infrared interface; transmission rate: MAX 115.2 kbps; cable interface: Start/Stop synchronization; Transmission speed: Max 38,400 bps; signal level: RS 232.

Light Source

Visible laser diode at 670 nm

A-1

Page 98

PDT 1100 Product Reference Guide

Table A-1. Terminal Specifications (Continued) Laser Class

CDRH Class II and IEC Class 2

Scan Angle

53º nominal

Scan Rate

36 ± 3 scans per second.

Minimum Print Contrast 20% absolute dark/light reflectance at 670 nm Interface Type

Serial RS-232, IrDA

Power

Two AAA alkaline batteries; new batteries provide up to 8,000 continuous scans; rechargeable NiMH battery pack optional.

Operating Temperature 32º to 103º F (-0º to 40º C) Drop Specification

Terminal withstands multiple 4 ft (1.2 meter) drops to concrete.

Humidity

10 to 90% RH noncondensing

Ambient Light

Artificial: 450 ft.-candles (4,844 lux) Sunlight: 8,000 ft.candles (86,112 lux)

Scan Engine Decode Zone (Vcc = 5V) The SE 1200 Wide Angle Scan Engine in your terminal decodes the symbols as shown in Figure A-1. Typical values are shown. Table A-2 lists the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown in Table A-2.

A-2

Page 99

Specifications

Note: Typical performance at 68 F (20 C) on high quality symbols.

In. 11.36 cm 28.8

5

12.7

0

0

5

12.7

11.36

28.8

PDT 1100

5 mil 2

4 7.5 mil 7.0

1.5

100% UPC

12

20 mil

W i d t h o f F i e l d

16 40 mil

*

20 55 mil 25

In. 0 cm 0

5 12.7

10 25.4

15 38.1

20 50.8

25 63.5

Depth of Field *Minimum distance determined by symbol length and scan angle

Figure A-1. Scan EngineTypical Decode Zone

Table A-2. Scan Engine Decode Distances Symbol Density

Typical

Guaranteed in.

mm in.

Min. cm in.

Max. cm in.

Min. cm in.

Max. cm

0.005

0.127

2

5.08

4

10.16

2

5.08

4

10.16

0.0075

0.191

1.5

3.81

7

17.78

1.5

3.81

7

17.78

A-3

Page 100

PDT 1100 Product Reference Guide

Table A-2. Scan Engine Decode Distances (Continued) 100% UPC

1.5

3.81

12

30.48

1.5

3.81

10

25.40

0.020

0.508

*

16

40.64

*

14

35.56

0.040

1.01

*

20

50.80

*

18

45.72

0.055

1.40

*

25

63.50

*

23

58.42

*Minimum distance determined by symbol length and scan angle.

Bar Code Specifications Table A-3. Bar Code Specifications Bar Code Type

Bar Dimensions

Readable Magnification

EAN-13

0.26 to 0.66 mm (10.24 to 13.0 mils)

0.8 to 1.0 magnification

EAN-8

0.26 to 0.46 mm (10.24 to 18.1 mils)

0.8 to 1.4 magnification

UPC-A

0.26 to 0.33 mm (10.24 to 13.0 mils)

0.8 to 1.0 magnification

UPC-E

0.26 to 0.56 mm (10.24 to 22.0 mils)

0.8 to 1.7 magnification

2-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

5-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

Interleaved 2 of 5 (ITF)

0.127 mm min. (5.0 mils min.) PCS value ≥ 0.9

Standard 2 of 5 (STF)

Reflection intensity difference between white and black bars ≥

Universal Product Codes

80%. Codabar (NW7)

A-4

0.15 mm min. (5.91 mils min.)

Page 101

Specifications

Table A-3. Bar Code Specifications (Continued) Bar Code Type

Bar Dimensions

Readable Magnification

Code 39

(PCS value ≥ 0.45)

Code 93

0.15 mm min. (5.91 mils min.) PCS value ≥ 0.9 Reflection intensity difference between white and black bars ≥ 80%

Code 128

0.19 mm min. (7.48 mils min.)

Communications Specifications Table A-4 lists the communications specifications for the PDT 1100 and a host computer via the CRD 1100 (optical interface) or direct-connect interface cable. Table A-4. Communication Specifications Communications Port

Optical Interface

Synchronization Transmission Speed Character Length Transmission Bit Order

Direct-connect Interface Start-stop

2400, 9600, 19200, 38400, 57600, or 115200 bps

300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps

8-bits

7- or 8-bits

LSB (Least significant bit) first

Response Method

ACK/NAK response

Vertical Parity

None

Even, odd, or none

Transparency

Transparent or non-transparent mode

Stop Bit Length

1 bit

1 or 2 bits

Synchronization For accurate data transaction, synchronize the transmission between the sender and receiver. To do this, define the bit order, position, the character length, and the beginning and end of the character to be transmitted. The start-stop synchronization is an asynchronous system which synchronizes each character as a unit; that is, it externally adds start and stop bits to the leading and trailing A-5

Page 102

PDT 1100 Product Reference Guide bit positions of the character to be transmitted, respectively. A clock starts counting when it receives the start bit and it stops communicating when the stop bit is received. The number of the stop bits is selectable (1 or 2 bits).

Optical Interface Communications Range The optical interface’s maximum effective range is 30 inches (80 cm) with the IR beam within a 10° angle of divergence.

Transmission Code and Bit Order All characters should be coded to 7- or 8-bit code for data transmission. The standard data exchange code of the PDT 1100 is 7- or 8-bit code. The transmission bit order is LSB (Least Significant Bit) first. Following is an example for transmitting character A (41h, 01000001b) coded to 8-level code with an even parity and a single bit for start and stop bits. LSB 1

0

Start Bit

0

0

0

0

1

0

0

Stop Bit Parity Bit

Figure A-2. Transmission Example

Response Method When two devices initiate communications, they exchange signals for correct data transmission. This procedure is called "handshaking” or "data link establishment phase." The sender sends a control code ENQ (05h) to inquire if the receiver is ready to receive data, and the receiver replies with a control code ACK (06h)(positive) or NAK (15h)(negative) to start data transmission.

Vertical Parity A vertical parity bit is a redundancy bit added to every character to be transmitted to check that data has been transmitted accurately. The parity bit should be set to "1" or "0" depending upon the parity parameter setting, to make the number of set bits in the character even or odd. The receiver counts the number of set bits in the transmitted character code to make sure that it has the selected number (even or odd) of set bits. The vertical parity bit immediately follows the MSB (Most Significant Bit) as shown in Figure A-3.

A-6

Page 103

Specifications

LSB b0

MSB b1 b2 b3 b4 b5 b6

Vertical Parity Bit LSB b0

MSB b1 b2 b3 b4 b5 b6 b7

Vertical Parity Bit

Figure A-3. Vertical Parity

BCC for Horizontal Parity Checking The PDT 1100 supports horizontal parity checking for every transmission block to check data transmission. A horizontal parity byte called BCC (Block Check Character) is appended after the ETX of every transmission block. Every parity bit of BCC is set so that all set bits at the same bit level (including a parity bit) in the transmission block characters have an even number by binary addition, excluding SOH, STX, and functions SOH$ and STX$. (For details about SOH$ and STX$ protocol functions which are unique to BASIC 3.0 interpreter, refer to the PDT 1100 Terminal Programmer’s Guide, p/n 70-36099-xx.) (Vertical Parity)

35864062.eps

Character

[For 8-bit Data]

Horizontal Parity Byte (BCC)

Figure A-4. Horizontal Parity Checking A-7

Page 104

PDT 1100 Product Reference Guide

IR Protocol The IR protocol is the communications procedure for the serial infrared link, used to transmit files between the PDT 1100 and a host (or between PDT 1100s). It adopts the ACK/NAK response method. The IR protocol can also be used for communications through the direct-connect interface. The IR protocol is composed of a defined set of the control character sequences including the following three phases: t

Phase 1: Establishment of data link - the sending station confirms that the receiving station is ready to receive data.

t

Phase 2: Data transmission - the sending station transmits data to the target receiving station.

t

Phase 3: Release of data link - the sending station confirms that transmitted data has been correctly received by the receiving station. If yes, the sending station terminates the data transmission and releases the data link.

This section lists the specifications for the optical interface and the direct-connect interface and describes the pin assignment.

Optical (Infrared) Interface •

Synchronization: Start-stop

•

Input signals: RD

•

Output signals: SD

•

Transmission speed: 115200 bps max.

Direct-connect Interface •

Synchronization: Start-stop

•

Transmission speed: 38400 bps max.

•

Signal level: Conforms to the RS-232C interface

•

Pin assignment: See Figure A-5.

SD

RD

SG or GND 35864048.eps

Figure A-5. Pin Assignment

A-8

Page 105

Specifications

Table A-5. Pin Description Pin No.

Signal

Functions

1

SG (GND)

Signal Ground

2

SD

Send data

3

RD

Receive data

Signal Input/Output PDT 1100 External

CRD 1100 Cradle Specifications This section lists the cradle specifications and the requirements for charging a NiMH battery pack in the cradle. Table A-6. CRD 1100 Specifications Power Source

12 VDC (via the AC Power Supply)

Power Consumption

2W

Dimensions (W) x (L) x (H)

82 x 190 x 57 mm (3.23 x 7.48 x 2.24 inches)

Weight

Charging Cradle: Approx. 240 g (Approx. 8.47 oz.) Non-charging cradle: Approx. 180 g (Approx. 6.35 oz.)

Operating Ambient Temperature

0°C to 40°C (32°F to 103°F)

Operating Humidity

20% to 80% RH (noncondensing)

Charging/Discharging Requirements (CRD 1100) For charging a NiMH battery pack in the PDT 1100: •

Charge current: 70 mA

•

Charge time: Approximately 10 hours.

For charging a NiMH battery pack alone: •

Charge current: 70 mA A-9

Page 106

PDT 1100 Product Reference Guide

•

Charge time: Approximately 10 hours

•

Discharge current: 180 mA

•

Discharge time: Approximately 3 hours.

Internal Connection in the CRD 1100 Host Computer, Modem or other device. Signal Name.

Pin

FG

1

SD

2

RD

3

RS

4

CS

5

DR

6

ER

20

CD

8

SG

7

Optical Interface Not used RS-232 Interface Circuitry

Optical Communication s Interface Circuitry

Figure A-6. Internal Connection

A-10

PDT 1100

Page 107

Specifications

Interface Specifications 13

1

25

14

Figure A-7. RS-232C Interface Port (Dsub-25S) on the CRD 1100 Table A-7. CRD 1100 Interface Port Specifications Pin No.

Signal

Functions

1

FG

Frame ground

2

SD

Send data

3

RD

Receive data

4

RS

Request to send

5

CS

Ready to send

6

DR

Data set ready

7

SG

Signal ground

8

CD

Carrier detect

20

ER

Data terminal equipment ready

Signal Input/Output PDT 1100 External

A-11

Page 108

PDT 1100 Product Reference Guide

CRG 1100 4-Slot Battery Charger Specifications Table A-8 lists the 4-slot Battery Charger specifications. Table A-8. 4-Slot Battery Charger Specifications

A-12

Type

Description

Input Voltage

DC10 ~12V

Current Consumption

2240mA (input voltage DC 12v)

Dimensions (W) x (L) x (H)

140cm x 140cm x 35cm 5.52 in. x 5.52 in. 1.38 in.

Weight

210g [0.463 lb] ±10%

Operating Ambient Temperature

0°C to 40°C (32°F to 103°F)

Operating Humidity

20% to 80% RH (noncondensing)