The text of a manual · part 12 of 16

PDT 1100 Terminal Product Reference Guide: Chapter 5 Battery Charging and Terminal Maintenance, pages 88 to 96

Pages 88 to 96 of 124, from PDT 1100 Terminal Product Reference Guide

The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-1100

Page 88

PDT 1100 Terminal Product Reference Guide

Table 5-2. CRG 1100 Components (Continued) Name

Description

Power Light

Illuminates when power is supplied. Blinks when power supply is faulty.

CHG/TRK Light

Illuminates throughout normal charging, blinks in case of abnormalities in battery charging (about every .5 seconds). Blinks about every 2 seconds during trickle charging.

DIS CHG Light

Lights up during discharge (slot 4 only).

Connecting the Power Supply The CRG 1100 is powered by an AC input 100-240VAC/DC output 12V 1.5A power supply (p/n 50-14000-103), and requires a DC inter-connect cable (p/n 50-16002-013). 1. Connect the DC inter-connect cable to the CRG 1100 and the other end to the power supply.

Figure 5-8. Connection of the AC Power Supply 2. Connect the power supply to the wall outlet.

Charging a Battery Pack The four battery slots on the CRG 1100 can charge independently. Slot 4 includes a discharge function. To charge a battery pack: 1. Turn the power switch to ON. The power light illuminates.

5-10

Page 89

Battery Charging and Terminal Maintenance

2. Insert the battery pack in a charging slot. Battery Pack

35864036.eps

Figure 5-9. Battery Pack in Charger 3. The CHG/TRK light illuminates for that slot, indicating charging 4. Charging completes after about 10 hours. The trickle charging (CHG/TRK) light blinks. 5. Remove the battery pack from the charger.

Battery Pack Maintenance Cycling If the battery pack begins to have a reduced operating time between charges, it may be due to “memory effect”. This effect can be eliminated or reduced by battery pack maintenance cycling, which fully discharges and then recharges the battery pack. Do not discharge completely more than once a month, or the battery pack will deteriorate quickly. To perform battery maintenance cycling: 1. Ensure that the power switch on the charger is OFF. 2. Insert a battery pack into slot 4. 3. Turn the power switch ON. 4. The DIS CHG light illuminates to indicate the battery pack is being discharged. 5. Charging begins when discharge is complete. The discharge/charge process takes about 13 hours.

5-11

Page 90

PDT 1100 Terminal Product Reference Guide

Batteries Charging the EDL Cap Charge the terminal for a minimum of two hours when powering up for the first time, or when the batteries are out of the terminal for a few minutes or more. There is insufficient backup power to maintain data if this is not done. There is no indication on the terminal or the cradle when the Electric Double Layer (EDL) cap is charging.

Battery Tips •

When you first load batteries or a battery pack into a PDT 1100 that is new or hasn’t been used for a long time, batteries must remain in the terminal for 24 hours. This allows the memory backup source integrated into the PDT 1100 to charge. This rechargeable memory backup source backs up the memory in the PDT 1100 when no batteries/battery pack is loaded, or the voltage level of the batteries/battery pack drops below the specified level. The memory backup source is automatically charged by the batteries/battery pack.

•

Replace the batteries or battery pack quickly. Leaving the PDT 1100 with no batteries or battery pack for a long time may cause loss of memory contents or a system error indicated by the message: "System error! Contact your administrator. Note the error drive. (Drive X)" on the LCD.

•

When disposing of the battery pack, cover the terminal pins with vinyl tape to prevent short-circuit.

•

Upload data frequently since the data stored in RAM might be affected by the "soft error" or other environmental phenomena.

Low Battery Indication The PDT 1100 displays two messages indicating the battery voltage is getting low. The first message is only a warning, and the second message is a warning followed by immediate shutdown of the terminal until the batteries are replaced or the battery pack is recharged. This shutdown prevents the memory backup source from discharging and resulting in memory loss.

5-12

Page 91

Battery Charging and Terminal Maintenance

Low Battery Indication - Level 1 If the voltage drops below specific levels while the PDT 1100 is in operation, the terminal displays:

Battery Voltage has lowered

The PDT 1100 then beeps three times and resumes normal operation. This message means that the batteries will expire soon. Replace the alkaline batteries or replace/charge the battery pack.

Low Battery Indication - Level 2 If you continue to use the PDT 1100 without battery replacement or recharge after the level 1 message appears, the PDT 1100 displays the following level 2 message, beeps five times, and turns itself off.

Charge the battery!

Replace the batteries!

OR

If either message appears, immediately turn the power off and replace or recharge the batteries. If you are using AAA batteries, make sure you have new batteries available before removing the old batteries. Replace the batteries within 3 minutes to retain your data. After battery replacement, power on and check the operation.

Battery Replacement and Charging Tips •

Before battery replacement, turn off the PDT 1100. Within three minutes after removal of the batteries/battery pack, load new batteries or a fully charged battery pack to avoid data loss. Power the PDT 1100 on and check its operation.

5-13

Page 92

PDT 1100 Terminal Product Reference Guide

•

When replacing alkaline batteries, always replace both.

•

You may charge the NiMH battery pack with the optional CRD 1100 cradle or CRG 1100 charger four-slot battery charger.

•

If the "Charge the battery!" or "Replace the batteries!" message appears after the PDT 1100 undergoes any shock or impact, turn the power off and on then check the battery output level. The battery may not have run out.

Storing the Terminal If you’re not planning to use the terminal for a while, store the terminal with new batteries (AAA or a fully charged NiMH battery pack) loaded. Note: The batteries expire after two to three months, even if the terminal is not used. Replace the batteries before they expire or the PDT 1100 will not back up the memory. Do not leave the terminal without batteries for more than one hour. This may shorten the service life of the backup battery (rechargeable lithium battery) in the PDT 1100. If the PDT 1100 is to be stored for a long time without batteries, to flush the contents of RAM (system parameters and user data) to ROM, press and hold the PWR key for more than three seconds. The following message appears: Now Saving Data Do not remove batteries until process complete

The backup process takes several minutes, depending on data capacity. The message disappears when backup is complete. Remove the batteries or battery pack. When the terminal is stored without batteries, the clock in the terminal may stop. The following screen appears when you power on the terminal: SET CURRENT TIME YY/MM/DD HH:MM 00/01/01 00:45 _ / / :

5-14

Page 93

Battery Charging and Terminal Maintenance

Set the current time. Contact your systems administrator for instructions.

Troubleshooting Following are checklists of common problems for the PDT 1100, CRD 1100, and CRG 1100.

PDT 1100 Table 5-3. Troubleshooting the PDT 1100 Problem

Possible Cause

PDT 1100 does not Battery pack is not power on. installed.

Solution Verify that the terminal has power from a battery pack.

Battery pack is not charged.

Charge the battery pack.

Battery pack is not installed correctly.

Install the battery pack correctly.

Scanner does not Scanning is not enabled. Enable scanning on the host computer. decode a bar code. Terminal is not programmed to read the type of bar code you are trying to scan.

Program the terminal to read the type of bar code you are trying to scan.

The bar code is unreadable.

Make sure the bar code is not defective, e.g., smudged or dirty.

Scan window is dirty.

Clean the scan window with lens tissue for use with eyeglasses.

No communication Loose cable connections Make sure the cable connections are not loose. between terminal (if cable is used). and host computer. Blocked IR port on terminal or cradle.

Make sure the IR ports on the terminal and the cradle are not blocked.

5-15

Page 94

PDT 1100 Terminal Product Reference Guide

CRD 1100 Table 5-4. Troubleshooting the CRD 1100 Problem No communication between terminal and cradle.

Power light does not illuminate.

NiMH battery pack did not charge.

Possible Cause

Solution

Terminal not seated properly in cradle.

Seat terminal properly in cradle.

Power switch is off.

Turn power switch on.

AC adapter not connected properly.

Properly connect AC adapter.

Power switch is off.

Turn power switch on.

Battery pack failed.

Replace the battery pack.

Insufficient charging time.

Allow the full 10 hours for battery pack to charge.

Battery charging Check and clean battery pack and charger terminals on the battery terminals. pack and the charger are dirty.

CRG 1100 Table 5-5. Troubleshooting the CRG 1100 Problem

Possible Cause

The Power light AC adapter is not does not illuminate. connected to an AC outlet. Charger power switch is not ON.

5-16

Solution Connect the AC adapter to an AC outlet.

Set the power switch to ON.

Page 95

Battery Charging and Terminal Maintenance

Table 5-5. Troubleshooting the CRG 1100 (Continued) Problem

Possible Cause

DIS CHG light does Battery pack is not not illuminate. inserted properly in slot 4.

Solution With the power switch OFF, insert the battery pack in slot 4 again, then turn the power switch ON.

Battery charging Clean the charging terminals on the battery pack terminals on the battery and the charger. pack and the charger are dirty. CHG/TRK light Battery pack is not does not illuminate. inserted properly in a charging slot.

Make sure the battery pack is properly inserted.

Battery charging Check and clean battery pack and charger terminals on the battery terminals. pack and the charger are dirty. Power light blinks.

AC power output is too low.

Make sure AC power output is sufficient.

Proper AC adapter is not Use proper AC adapter. used. The CHG/TRK light There is an abnormality blinks. in the battery pack.

Insert another battery pack to see if the same problem occurs. If it does, contact the dealer.

5-17

Page 96 read from a scan by OCR; it may hold reading errors

NO yA |_! PDT 1100 Terminal Product Reference Guide

5-18