For the Symbol P460

Page 185

Appendix B Automatic Project Download The Phaser P470/P370 RF scanner is shipped from the factory with a pre-installed default application. This fully functional application allows the scanner to be used “out of the box”. If you need to load your own application into the scanner, the “Automatic Project Download” feature will simplify the process. When the default application is running, and the scanner is placed into its paired cradle, the scanner will query the MCL-Link host for data in a file named “PHASER.CFG”. The scanner will use the information in this file to find the project directory which the user wishes to have loaded into the scanner, and will then execute the PROJECT.CMD” script which exists in the directory. This script will automatically download all program and data files relevant to the project to the scanner and will reset the scanner making it ready to run the user’s application. In order to utilize this mechanism, the user needs only generate the PHASER.CFG file and place it in the directory specified in the MCL-Link setup screen as the “General path for data files”. Any text editor may be used to create this file; the contents of the file are as follows: X|<path name to the user’s project>

The X| at the beginning of the line are required for the MCL-Net CR command to recognize this file and read the data. The path name should include the entire path hierarchy. Also, all backslashes (\) in the path name should be replaced with the string “\5C”, so that the MCL code running on the scanner does not inadvertently convert part of the path name to the equivalent Hex Character. An example PHASER.CFG file is shown below: x|c:\5Cmcl-p460\5Cdesigner\5Csample1.prj

B-1

Page 186

P470/370 RF Scanner Product Reference Guide

Note that designer always appends the .prj suffix to the directories it creates to store project files. The PROJECT.CMD file will be automatically generated by the MCL-Designer application.

B-2

Page 187

Appendix C Messages and Error Codes Introduction This chapter contains information on messages displayed on the scanner.

Messages The scanner displays messages when certain actions are performed. If the scanner displays a message that is unfamiliar, contact the Symbol Support Center on page -xi.

Table C-1. Scanner Messages Message Unit Cradled

Description Scanner is properly inserted in the cradle

Battery Temperature Out Of Battery temperature is out of range. Contact a Range Symbol Support Center on page -xi. Upload Failed. Retry <Enter>=Yes <BK>=No

•

•

After putting the scanner in the mode to transmit batch data to the host, it was not placed in the cradle or attached to a cable within the required 30 seconds. Communication failure with host due to host or cabling problems. Use the beeper indications to track the message. See Beeper Indications on page 4-9.

C-1

Page 188

P460/P360 Memory Scanners Product Reference Guide

C-2