The text of a manual · part 16 of 23
P460/P360 Memory Scanners Product Reference Guide: Chapter 5 Parameter Menus, pages 131 to 140
Pages 131 to 140 of 198, from P460/P360 Memory Scanners Product Reference Guide
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P460
Page 131
Parameter Menus
I 2 of 5 Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).
*DISABLE
USS CHECK DIGIT
OPCC CHECK DIGIT
5-61
Page 132
P460/P360 Memory Scanners Product Reference Guide
Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit.
TRANSMIT I 2 of 5 CHECK DIGIT (ENABLE)
*DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE)
5-62
Page 133
Parameter Menus
Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
CONVERT I 2 of 5 to EAN-13 (ENABLE)
*DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE)
5-63
Page 134
P460/P360 Memory Scanners Product Reference Guide
Enable/Disable Discrete 2 of 5 Scan the appropriate bar code below to enable or disable Discrete 2 of 5.
ENABLE DISCRETE 2 OF 5
*DISABLE DISCRETE 2 OF 5
5-64
Page 135
Parameter Menus
Set Lengths for Discrete 2 of 5 Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. The default is set to a length of 12 characters. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select D 2 of 5 One Discrete Length, then scan 1, 4, the only D 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
D 2 of 5 - ONE DISCRETE LENGTH
Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only D 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, CANCEL on page 5-101.
D 2 of 5 - TWO DISCRETE LENGTHS
5-65
Page 136
P460/P360 Memory Scanners Product Reference Guide
Set Lengths for Discrete 2 of 5 (Continued) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
D 2 of 5 - LENGTH WITHIN RANGE
Any Length - Scanning this option allows you to decode D 2 of 5 symbols containing any number of characters. Note: Selecting this option may lead to mis-decodes for D 2 of 5 codes.
D 2 of 5 - ANY LENGTH
5-66
Page 137
Parameter Menus
Enable/Disable Codabar Scan the appropriate bar code below to enable or disable Codabar.
ENABLE CODABAR
*DISABLE CODABAR
5-67
Page 138
P460/P360 Memory Scanners Product Reference Guide
Set Lengths for Codabar Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. It also includes any start or stop characters. The default is set to a length of 5 to 55 characters. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Codabar One Discrete Length, then scan 1, 4, the only Codabar symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
CODABAR - ONE DISCRETE LENGTH
Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, the only Codabar symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
CODABAR - TWO DISCRETE LENGTHS
5-68
Page 139
Parameter Menus
Set Lengths for Codabar (Continued) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-99. If you make an error, or wish to change your selection, scan CANCEL on page 5-101.
CODABAR - LENGTH WITHIN RANGE
Any Length - Scanning this option allows you to decode Codabar symbols containing any number of characters.
CODABAR - ANY LENGTH
5-69
Page 140
P460/P360 Memory Scanners Product Reference Guide
CLSI Editing If enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters.
ENABLE CLSI EDITING
*DISABLE CLSI EDITING
5-70