The text of a manual · part 15 of 22
P460/P360 Memory Scanners Product Reference Guide: Chapter 5 Parameter Menus, pages 109 to 118
Pages 109 to 118 of 188, from P460/P360 Memory Scanners Product Reference Guide
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol P360 and Symbol P460
Page 109
Parameter Menus
Enable/Disable ISBT 128 (2D Scanner only) To enable or disable ISBT 128, scan the appropriate bar code below.
Enable ISBT 128
Disable ISBT 128
5-41
Page 110
P460/P360 Memory Scanners Product Reference Guide
Enable/Disable Code 39 Scan the appropriate bar code below to enable or disable Code 39.
*ENABLE CODE 39
DISABLE CODE 39
5-42
Page 111
Parameter Menus
Enable/Disable Trioptic Code 39 Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
ENABLE TRIOPTIC CODE 39
*DISABLE TRIOPTIC CODE 39
5-43
Page 112
P460/P360 Memory Scanners Product Reference Guide
Set Lengths for Code 39 Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. The default is set to a length of 2 to 55 characters. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-95. If you make an error, or wish to change your selection, scanCANCEL on page 5-97.
CODE 39 - ONE DISCRETE LENGTH
Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-95. If you make an error, or wish to change your selection, scan CANCEL on page 5-97.
CODE 39 - TWO DISCRETE LENGTHS
5-44
Page 113
Parameter Menus
Set Lengths for Code 39 (Continued) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-95. If you make an error, or wish to change your selection, scan CANCEL on page 5-97.
CODE 39 - LENGTH WITHIN RANGE
Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters.
CODE 39 - ANY LENGTH
5-45
Page 114
P460/P360 Memory Scanners Product Reference Guide
Code 39 Check Digit Verification When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms. Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.
ENABLE CODE 39 CHECK DIGIT
*DISABLE CODE 39 CHECK DIGIT
5-46
Page 115
Parameter Menus
Transmit Code 39 Check Digit Scan the appropriate bar code below to transmit the data with or without the check digit.
TRANSMIT CODE 39 CHECK DIGIT (ENABLE)
*DO NOT TRANSMIT CODE 39 CHECK DIGIT (DISABLE)
5-47
Page 116
P460/P360 Memory Scanners Product Reference Guide
Enable/Disable Code 39 Full ASCII Scan the appropriate bar code below to enable or disable Code 39 Full ASCII. When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. Refer to the ASCII table in Appendix A. Code 39 Full ASCII and Trioptic Code 39 cannot be enabled simultaneously. If you get an error beep when enabling Code 39 Full ASCII, disable Trioptic Code 39 and try again. The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.
ENABLE CODE 39 FULL ASCII
*DISABLE CODE 39 FULL ASCII
Note: The “|” character and the NULL character cannot be embedded in the barcode to be scanned when using Code 39 Full ASCII.
5-48
Page 117
Parameter Menus
Convert Code 39 to Code 32 Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Note: Code 39 must be enabled in order for this parameter to function.
CONVERT CODE 39 TO CODE 32 (ENABLE)
*DO NOT CONVERT CODE 39 TO CODE 32 (DISABLE)
5-49
Page 118
P460/P360 Memory Scanners Product Reference Guide
Code 32 Prefix Scan the appropriate bar code below to enable or disable the prefix character “A” to all Code 32 bar codes. Note: Convert Code 39 to Code 32 must be enabled for this parameter to function.
ENABLE CODE 32 PREFIX
*DISABLE CODE 32 PREFIX
5-50