Page 77
Programming the Scanner
Transmit UPC-E1 Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC-E1 check digit
Transmit UPC-E1 Check Digit
Do Not Transmit UPC-E1 Check Digit
2-41
Page 78
P 300STD/FZY/PRO Scanner Product Reference Guide
UPC/EAN Security Level The P 300 Series scanner offers four levels of decode security for UPC/EAN bar codes. Select a higher level of security for poor quality bar codes. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for your application.
UPC/EAN Security Level 0 This default setting allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
UPC/EAN Security Level 0
UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to misdecodes before others (i.e., 1, 2, 7, 8). If you are experiencing misdecodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.
UPC/EAN Security Level 1
2-42
Page 79
Programming the Scanner
UPC/EAN Security Level 2 If you are experiencing misdecodes of poorly printed bar codes, and the misdecodes are not limited to characters 1, 2, 7, and 8, select this security level.
UPC/EAN Security Level 2
UPC/EAN Security Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised, selecting this option is an extreme measure against misdecoding severely out of spec bar codes, and security significantly impairs the decoding ability of the scanner. If this level of security is necessary, try to improve the quality of your bar codes.
UPC/EAN Security Level 3
2-43
Page 80
P 300STD/FZY/PRO Scanner Product Reference Guide
EAN-8 Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
Enable EAN-8 Zero Extend
Disable EAN-8 Zero Extend
2-44
Page 81
Programming the Scanner
Convert EAN-8 to EAN-13 Type When EAN Zero Extend is enabled, this parameter gives you the option of labeling the extended symbol as either an EAN-13 bar code, or an EAN-8 bar code. This affects Transmit Code ID Character and DECODE_DATA message. When EAN Zero Extend is disabled, this parameter has no effect on bar code data.
Type Is EAN-8
Type Is EAN-13
2-45
Page 82
P 300STD/FZY/PRO Scanner Product Reference Guide
Enable/Disable Code 128 To enable or disable Code 128, scan the appropriate bar code below.
Enable Code 128
Disable Code 128
2-46
Page 83
Programming the Scanner
Enable/Disable UCC/EAN-128 To enable or disable UCC/EAN-128, scan the appropriate bar code below. (See Appendix A, Programming Reference for details on UCC/EAN128.)
Enable UCC/EAN-128
Disable UCC/EAN-128
2-47
Page 84
P 300STD/FZY/PRO Scanner Product Reference Guide
Enable/Disable ISBT 128 To enable or disable ISBT 128, scan the appropriate bar code below.
Enable ISBT 128
Disable ISBT 128
2-48
Page 85
Programming the Scanner
Lengths for Code 128 No length setting is required for Code 128. The default setting is Any Length.
2-49
Page 86
P 300STD/FZY/PRO Scanner Product Reference Guide
Enable/Disable Code 39 To enable or disable Code 39, scan the appropriate bar code below.
Enable Code 39
Disable Code 39
2-50