For the Symbol P300

Page 87

Programming the Scanner

Enable/Disable Trioptic Code 39 Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.

Enable Trioptic Code 39

Disable Trioptic Code 39

Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again.

2-51

Page 88

P 300STD/FZY/PRO Scanner Product Reference Guide

Set Lengths for Code 39 Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), the code contains, including check digit(s) . If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2122.

Code 39 - One Discrete Length

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

Code 39 -Two Discrete Lengths

2-52

Page 89

Programming the Scanner

Length Within Range - This option allows you to decode a code type within a specified range. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 2-120. If you make an error or wish to change your selection, scan CANCEL on page 2-122.

Code 39 - Length within Range

Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters.

Code 39 - Any Length

2-53

Page 90

P 300STD/FZY/PRO Scanner Product Reference Guide

Code 39 Check Digit Verification When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms. Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.

Enable Code 39 Check Digit

Disable Code 39 Check Digit

2-54

Page 91

Programming the Scanner

Transmit Code 39 Check Digit Scan this symbol if you want to transmit the check digit with the data.

Transmit Code 39 Check Digit (Enable)

Do Not Transmit Code 39 Check Digit (Disable)

2-55

Page 92

P 300STD/FZY/PRO Scanner Product Reference Guide

Enable/Disable Code 39 Full ASCII To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent of ABC ENTER. Refer to Table C-1 on page C-1. The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.

Enable Code 39 Full ASCII

Disable Code 39 Full ASCII

Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again.

2-56

Page 93

Programming the Scanner

Code 39 Buffering (Scan & Store) When you select the Buffer Code 39 option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further details. When the Do Not Buffer Code 39 option is selected, decoded Code 39 symbols without leading spaces are transmitted immediately. Scan and Store affects Code 39 decodes only. If you select scan and store, we recommend that you configure the scanner to decode Code 39 symbology only.

Buffer Code 39 (Enable)

Do Not Buffer Code 39 (Disable)

While there is data in the transmission buffer, disabling Code 39 buffering via the parameter menu is not allowed. The buffer holds 200 bytes of information. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer. Both the CLEAR BUFFER and TRANSMIT BUFFER bar codes are length 1. Be sure Code 39 length is set to include length 1.

2-57

Page 94

P 300STD/FZY/PRO Scanner Product Reference Guide

Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. !

Unless symbol overflows the transmission buffer, the scanner gives a low/high beep to indicate successful decode and buffering. See Overfilling Transmission Buffer.

!

The scanner adds the message, excluding the leading space, to the transmission buffer.

!

No transmission occurs.

Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. !

The scanner issues a short high/low/high beep to signal that the transmission buffer has been erased, and no transmission has occurred.

!

The scanner erases the transmission buffer.

!

No transmission occurs.

Clear Buffer

Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. !

The scanner signals that the transmission buffer has been sent (a low/high beep).

!

The scanner sends the buffer.

!

The scanner clears the buffer.

Transmit Buffer

2-58

Page 95

Programming the Scanner

2. A Code 39 bar code with a leading character other than a space. !

The scanner signals a good decode and buffering of that decode has occurred by giving a high/low beep.

!

The scanner transmits the buffer.

!

The scanner signals that the buffer has been transmitted with a low/high beep.

Overfilling Transmission Buffer If a decoded symbol results in an overflow of the transmission buffer: !

The scanner indicates that the symbol has been rejected by issuing three long, high beeps.

!

No transmission occurs. Data in the buffer is not affected.

Attempt to Transmit an Empty Buffer If a decoded symbol was the transmit buffer symbol and the Code 39 buffer is empty: !

A short low/high/low beep signals that the buffer is empty.

!

No transmission occurs.

!

The buffer remains empty.

2-59

Page 96

P 300STD/FZY/PRO Scanner Product Reference Guide

Convert Code 39 to Code 32 Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Note: Code 39 must be enabled in order for this parameter to function.

Convert Code 39 to Code 32

Do Not Convert Code 39 to Code 32

2-60