Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 9

NetVision Data Phone Product Reference Guide, pages 71 to 80

Pages 71 to 80 of 90

The original document is the PDF (924 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Symbol NP-3010 and Symbol NP-4046

Page 71

Appendix D

Technical Data Performance Characteristics Phone Protocol. ITU H.323 version 1 compliant; interoperable with Intel® Proshare® and Microsoft® NetMeeting®. Voice Compression. G.711 ×law. 64Kb, G.729A 8.0Kb, True Speech 8.5Kb. Web Client. Supports HTML 3.2 and HTTP 1.1; configurable toolbar layout and buttons; standard GIF file format for images and animation; proxy server and firewall support. Call Answer Time. Five seconds minimum, ten maximum. Codec. 8000 samples/sec., 8 bits/sample (×law compounding). Voice Packet Size. 30 to 480 bytes/packet, 20 to 60ms/packet. Response Time to Page. ten seconds average; fifteen seconds maximum. Battery. 7.2 volts rechargeable; Lithium ion. Battery Life. 150 minutes (2.5 hour) talk time, 24 hours of standby operation per charge. Battery meter.

Network Characteristics RF Data Communications. TCP/IP; supports IEEE 802.11 protocols. Wireless Access Protocol. CSMA/CA. Frequency Range. 2.4 - 2.485 GHz. Number of Hops. 79. Hopping Rate. 10 hops/second.

NetVision Data Phone Product Reference Guide

D-1

Page 72

Technical Data

Hopping Sequences. 66. Data Rate. 1 Mbps. Wireless Output Power. 100 mW. Range. 1,000+ ft./300+ meters.

Physical Characteristics Dimensions. 1" x 2" x 6"/2.54 cm x 5.08 cm x 15.24 cm. Weight. 8 oz./227 gm. Display. LCD: 16 line, 12 characters. Buttons. 0-9, *, #, Clear, Store, Recall, Hold, Previous, Scan, Next, End, Function, Name, Menu, Send; Alpha keys accessed via Function key. Notification. Ringer/Vibration/LED. Ports. 1 serial.

Scanner Characteristics Light Source. Visible Laser Diode at 650 nm. Laser Class. CDRH Class II, IEC 825 Class 2. Scan Angle. 53° nominal. Scan Rate. 36±3 scans per second. Minimum Print Contrast. 25% absolute dark/light reflectance at 650 nm.

User Environment Drop Specification. 3.3 ft./1 meter to tile. Temperature. -30°C to 60°C/-22°F to 140°F.

D-2

NetVision Data Phone Product Reference Guide

Page 73

Appendix E

Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products. If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support. Symbol Customer Support responds to calls by email, telephone or fax within the time limits set forth in individual contractual agreements. When contacting Symbol Customer Support, please provide the following information: • serial number of unit

• model number or product name

• software type and version number

•

Gateway vendor and model number

•

PBX vendor and model number.

North American Contacts Inside North America, contact Symbol by: •

Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 Telephone: 1-516-738-2400/1-800-SCAN 234 Fax: 1-516-738-5990

•

Symbol Support Center: – telephone: 1-800-653-5350

– fax: (516) 563-5410

–

Email: support@symbol.com

NetVision Data Phone Product Reference Guide

E-1

Page 74

Customer Support

International Contacts Outside North America, contact Symbol by: •

Symbol Technologies Technical Support 12 Oaklands Park Berkshire, RG41 2FD, United Kingdom Tel: 011-44-118-945-7000 or 1-516-738-2400 ext. 6213

Additional Information Obtain additional information by contacting Symbol at:

E-2

•

1-800-722-6234, inside North America

•

+1-516-738-5200, in/outside North America

• http://www.symbol.com

NetVision Data Phone Product Reference Guide

Page 75

Appendix F

Regulatory Compliance To comply with U.S. and international regulatory requirements, the following information has been included. The document applies to the complete line of Symbol products. Some of the labels shown, and statements applicable to other devices might not apply to all products.

Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •

Re-orient or relocate the receiving antenna.

•

Increase the separation between the equipment and receiver.

•

Connect the equipment into an outlet on a circuit different from that which the receiver is connected.

•

Consult the dealer or an experienced radio/TV technician for help.

NetVision Data Phone Product Reference Guide

F-1

Page 76

Regulatory Compliance

Radio Frequency Interference Requirements - Canada This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations.

CE Marking & European Union Compliance Products intended for sale within the European Union are marked with the CEMark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included: Normes (EN), as follows.

Applicable Directives:

F-2

•

Electromagnetic Compatibility Directive 89/336/EEC

•

Low Voltage Directive 73/23/EECApplicable Standards:

•

EN 55 022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information technology Equipment

•

EN 50 082-1 - Electromagnetic Compatibility - Generic Immunity Standard, Part 1: Residential, commercial, Light Industry

•

IEC 801.2 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 2: Electrostatic Discharge Requirements

•

IEC 801.3 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 3: Radiated Electromagnetic Field Requirements

•

IEC 801.4 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 4: Electrical Fast Transients Requirements

•

EN 60 950 + Amd 1 + Amd 2 - Safety of Information Technology Equipment Including Electrical Business Equipment

•

EN 60 825-1 (EN 60 825) - Safety of Devices Containing Lasers

NetVision Data Phone Product Reference Guide

Page 77

Regulatory Compliance

RF Devices Symbol’s RF products are designed to be compliant with the rules and regulations in the locations into which they are sold and will be labeled as required. The majority of Symbol’s RF devices are type approved and do not require the user to obtain license or authorization before using the equipment. Any changes or modifications to Symbol Technologies equipment not expressly approved by Symbol Technologies could void the user’s authority to operate the equipment.

Laser Devices Symbol products using lasers comply with US 21CFR1040.10, Subchapter J and IEC825/EN 60 825 (or IEC825-1/EN 60 825-1, depending on the date of manufacture). The laser classification is marked one of the labels on the product. Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous visible or invisible laser light exposure.

Class 2 laser scanners use a low power, visible light diode. As with any very bright light source, such as the sun, the user should avoid staring directly into the light beam. Momentary exposure to a Class 2 laser is not known to be harmful.

NetVision Data Phone Product Reference Guide

F-3

Page 78

Regulatory Compliance

F-4

NetVision Data Phone Product Reference Guide

Page 79

Appendix G Phone Configuration Worksheet Use this worksheet to organize local network information. Site Name ESS ID Router IP Address FTP IP Address DNS IP Address

_____________________ _____________________ _____________________ _____________________ _____________________

_____________________ _____________________ _____________________ _____________________ _____________________

Site Style Subnet Mask PBX IP address Message Server IP address DNS Name

Use this worksheet to organize configuration information. IP Address

Extension

Profile name

PIN

Dialing Scheme

Intercom groups

Use this worksheet to define PBX features for the NetVision Data Phone. Phone Function Key

Name of function

FCT,1 FCT,2 FCT,3 FCT,4 FCT,5 FCT,6 FCT,7 HOLD

NOT APPLICABLE

Character Sequence

Messaging

Page 80

G-2

NetVision Data Phone Product Reference Guide