Extension and Outside Number Dialing If the network is configured, the Data Phone can make calls to other Data Phones and wired phones on the network, and can send and receive outside phone calls. - To call to an extension, dial the extension number and press SND. - To call an outside number, dial the network-specific code to access the outside line, then dial the number along with required long distance access codes. The dialing function allows 31 digits maximum. See the network administrator for details for using access codes.
Name Dialing The NetVision Data Phone can contain a list of up to 25 users set up by the network administrator. 1. Press volume buttons or NAME to activate the name list. 2. Select the desired name and press SND to initiate the call. Use alphanumeric keys to jump to specific names when the list is long. 1. Press NAME. 2. Press the alphanumeric key with the character corresponding to the letter of the user name. If a letter has no entries, the phone displays No entries for #. Use the scroll keys for smaller cursor movements through the list. 3. Press SND to initiate the call to the selected user.
Call Redialing The NetVision Data Phone stores the last eight calls, including intercom calls and calls made from the NetVision Data Phone. The NetVision Data Phone does not store the numbers for external calls. 1. Press RCL to display the last call. Press RCL to scroll through the list. Do not use the scroll keys. 2. Press SND to initiate the call.
Speed-Dialing Depending on the network configuration, you can speed-dial to other NetVision phones, local extensions or outside phone numbers programmed into the speed-dial directory. 1. Press RCL to activate the speed-dial list. 2. Key in the speed-dial reference number (00-99) or use the scroll keys to select the listed number. 3. Press SND to activate the call. To add or replace a number in the speed-dial list: 1. Key in the desired number and press STO. 2. Enter the two-digit number referencing the location to add or replace the number on the list. The phone stores the number in the list, and returns to the status display.
Clearing the Speed-Dial List To clear existing numbers from the speed-dial list: 1. Press MENU to display the Main menu. 2. Select User Options and press SND. 3. Select Clear SD from the User options Menu. 4. Press SND to clear the speed-dial list.
Page 8
Intercom Calling This feature allows NetVision Phone users to connect to users of a group. NetVision Data Phone users can belong to as many as 10 intercom groups. The network administrator manages access levels to the intercom groups. You can communicate with only one intercom group at a time. The NetVision Data Phone automatically answers an intercom call if a call is not currently active. If a call is active, a threebeep alert indicates that a call is waiting. The Data Phone enters the intercom call when you end or place the current call on hold. 1. Press #. 2. Enter the intercom group number (0-9) and Press SND. The NetVision Data Phone dials the intercom group, and occupies the channel until the call terminates.
Message Paging This feature allows the NetVision Data Phone to receive messages similar to most pagers. Depending on the configuration, the network administrator can arrange for other network users to send messages to the NetVision Data Phone. The Data Phone alerts you to new messages with a special tone. To view messages: 1. Press FCT, RCL. 2. Press SND to view the last new message received. 3. Press SND repeatedly to scroll through messages or type in the number corresponding to a specific message. Press RCL repeatedly to scroll through the Subject, Sender and Recipient fields. To delete a message, press CLR while viewing the message. Press END to return to phone operations.
Page 9
Data Collection Features The NetVision Data Phone can collect data for many different applications. The type of data collected depends on the network configuration. You can enter data by keypad entry or using the built-in, bar code scanner. To scan a bar code: 1. Aim the top of the NetVision Data Phone towards the bar code. Adjust the distance to the bar code. Hold the Data Phone farther away for larger bar codes. Optimum distance is approximately six to ten inches (15 to 25 cm). 2. Press SCAN to switch to the data collection application. Observe that the scan beam crosses all the bars of the bar code. The call indicator turns green and the Data Phone beeps after successfully reading the bar code. The scanning success depends on the quality, size of the bar code, and the scan distance and angle of the scanner.
Do not stare into laser aperture.
Page 10
Manually Entering Data The NetVision Data Phone performs data entry best using the scanner. However, you can enter alphanumeric characters using the keypad. To enter alphanumeric characters, press and hold FCT, then press a keypad key to display a list of characters associated with that key.
Navigating through Data Collection Applications This feature maps the Data Phone keypad to functions different than when operating during a call. Press Key NAME STO RCL
Key Function Application help Scroll keys Edit keys
Status Indicator B S E
Application Control Keys Press and hold NAME and press any of the following keys to access application features: < > 1 2 3 4
Moves backward through application screens. Moves forward through application screens. Hides/shows an application field. Moves to the current application Home screen. Stops the current application. Reloads the current application.
Application Scroll Keys Press and hold STO and press any of the following keys to move through a page: < > 8 0 4 6 2 5
Scrolls the page towards the left margin. Scrolls the page towards the right margin. Scrolls the page towards the top margin. Scrolls the page towards the bottom margin. Scrolls the page one column towards the left margin. Scrolls the page one column towards the right margin. Scrolls the page one line towards the top margin. Scrolls the page one line towards the bottom margin.
Application Edit Keys Press and hold RCL and press any of the following keys edit data: < > 1 2 3 4 8 0
Moves the cursor over the previoous character. Moves the cursor over the next character. Moves cursor to beginning of a field. Moves cursor to end of a field. Deletes a character. Backspaces over a character. In a multi-line field moves cursor up one line. In a multi-line field moves cursor down one line.
Page 11
Data Phone Ring Styles This feature allows NetVision Data Phone users to select different rings to announce incoming phone and intercom calls. You can also add the vibrator to the ring selection. Tone 1 Tone 2 Tone 3 Tone 4 Tone 5 Tone 6 LED-only Vibrator
One-second beep Two short beeps A half-second beep A two-second beep One short beep Five short beeps Repeated LED flashes Repeated brief vibrations
To set the ring styles: 1. Press MENU. 2. Select User Options and press SND. 3. Select Phone Ring and Press SND. 4. Select a ring style from the menu and press SND. The phone rings once using the selected tone. Press END to cancel.
Adding Vibration to Ring Style 1. Press MENU. 2. Select User Options. Press SND. 3. Select Ring Vibrate and press SND. 4. Select Enable or Disabled and press SND to set. Press END to cancel.
Data Phone Ring Volume This feature allows you to adjust the ring volume for incoming calls. 1. Press MENU. 2. Select User Options and press SND. 3. Select Ring Volume and press SND. 4. Set the ring volume level and press SND. Press END to cancel.
Key Locking This feature allows you to lock the keypad to prevent accidental Data Phone operation and unnecessary battery power consumption. Any incoming call automatically unlocks the keypad. 1. Press MENU. 2. Select User Options and press SND. 3. Select Keypad Lock and press SND. 4. Select Enable or Disabled and press SND. Press END to cancel. To unlock the keypad before initiating a call or other phone function, press and hold SND until the phone status changes to Idle.
Controlling LCD Contrast You can configure the NetVision Data Phone display contrast levels for readibility in different environments. 1. Press MENU. 2. Select User Options and press SND. 3. Select Contrast and press SND. 4. Select the contrast level and press SND. Press END to cancel.
Page 12
Regulatory Compliance To comply with U.S. and international regulatory requirements, the following information has been included. The document applies to the complete line of Symbol products. Some of the labels shown, and statements applicable to other devices might not apply to all products. Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radio Frequency Interference Requirements - Canada This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations. CE Marking & European Union Compliance Products intended for sale within the European Union are marked with the CEMark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included: Normes (EN), as follows. Applicable Directives: Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Applicable Standards: EN 55 022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment EN 50 082-1 - Electromagnetic Compatibility - Generic Immunity Standard, Part 1: Residential, commercial, Light Industry IEC 801.2 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 2: Electrostatic Discharge Requirements IEC 801.3 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 3: Radiated Electromagnetic Field Requirements IEC 801.4 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 4: Electrical Fast Transients Requirements EN 60 950 + Amd 1 + Amd 2 - Safety of Information Technology Equipment Including Electrical Business Equipment EN 60 825-1 (EN 60 825) - Safety of Devices Containing Lasers RF Devices Symbol RF products are designed to be compliant with the rules and regulations in the locations into which they are sold and will be labeled as required. The majority of Symbol RF devices are type approved and do not require the user to obtain license or authorization before using the equipment. Any changes or modifications to Symbol Technologies equipment not expressly approved by Symbol Technologies could void user authority to operate the equipment. Laser Devices Symbol products using lasers comply with US 21CFR1040.10, Subchapter J and IEC825/EN 60 825 (or IEC825-1/EN 60 825-1, depending on the date of manufacture). The laser classification is marked one of the labels on the product. Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous visible or invisible laser light exposure. Class 2 Laser scanners use a low power, visible light diode. As with any very bright light source, such as the sun, the user should avoid staring directly into the light beam. Momentary exposure to a Class 2 laser is not known to be harmful. Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581 Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713