Page 17

Chapter 1 Introduction

! Caution Use of controls, adjustments or procedures other than those specified here can result in hazardous laser light exposure.

Overview The MiniScan family of fixed-mount scanners are specifically designed for stand-alone applications, and OEM applications such as kiosks.

1-1

Page 18

MS-804FZY and MS-904HS Integration Guide

Figure 1-1. MiniScan Family of Scanners MS-804FZY and MS-904HS scanners are extremely compact, provide easy and flexible integration of bar code scanning into a host device, and offer high-performance scanning on 1D bar codes. The MS-804FZY is ideal for medical instruments and manufacturing applications, and the MS-904HS is perfect for applications such as clinical diagnostics, conveyer belts or assembly lines.

1-2

Page 19

Introduction

MiniScan MS-804FZY and MS-904HS Features •

Stand-alone or OEM applications

•

Quick and easy integration for OEM devices

•

Excellent scanning performance on 1D bar codes

•

Easy programming and configuration

•

Flexible mounting options.

Typical Applications MiniScan is the perfect solution for the following applications: Fixed Mount Standalone Applications •

Clinical diagnostics

•

Medical instruments

•

Conveyer belts

•

Assembly lines.

OEM Applications •

Kiosks / ATMs

•

Music listening stations

•

Medical instruments

•

Clinical diagnostics

•

Lottery terminals / gaming.

1-3

Page 20

MS-804FZY and MS-904HS Integration Guide

Block Diagram The MiniScan block diagram illustrates the functional relationship of the MiniScan components. A detailed description of each component in the block diagram is also provided.

Interface Board Beeper External Beeper

DB9

Interface Circuit MS804FZY/904HS = RS232 flex

Interface

Decoded Scan Scan Engine

Engine

Red/ Green LED External Trigger

Figure 1-2. MiniScan Block Diagram

Miniscan Block Diagram Descriptions Decoded Scan Engine - The scan engine emits a beam of laser light that reflects off the bar code to be decoded. Black bars absorb light, white spaces reflect light. The scan engine collects the reflected light and processes the signal through several analog filters. The filtered signal is digitized into a Digitized Barcode Pattern (DBP). Timing information is analyzed by the decoder micro-controller to decode and transmit the data contained in the bar code. Data transmission is carried out using Symbol's proprietary SSI Interface.

1-4

Page 21

Introduction

Interface Board - The interface board converts TTL level SSI signals to proper RS-232 levels for connection to any RS-232 compliant host. It also contains a red/green LED for visual feedback, and provides for an external trigger and external beeper. DB9 - The DB9 connector provides various interface signals used between a MiniScan scanner and the host. It also maintains pin compatibility with the previous generation LS 1220 host cables.

Scanning Pattern The MS-804FZY and MS-904HS scanners emit a single scan line to quickly decode 1D bar codes.

Figure 1-3. Single Scan Line Scan Pattern

1-5

Page 22

MS-804FZY and MS-904HS Integration Guide

Beeper and LED Definitions Table 1-1 provides standard beeper definitions, and Table 1-2 provides LED definitions. Table 1-1. Standard Beeper Definitions (External Beeper Required) Beeper Sequence

Indication

Standard Use 1 Beep - short high tone

A bar code symbol was decoded (if decode beeper is enabled).

1 Beep - long high tone

Thermal shutdown.

Parameter Menu Scanning 2 Beeps- short high tone

Correct entry scanned or correct menu sequence performed.

1 Beep- hi/lo/hi/lo tone

Successful program exit with change in the parameter setting.

2 Beeps - lo/hi tone

Input error, incorrect bar code, or Cancel scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

Communication 4 Beeps - short high tone

Communication error.

4 Beeps - hi/hi/hi/lo

Receive error.

3 Beeps - lo/hi/lo

ADF transmit error.

Table 1-2. LED Definitions LED

1-6

Indication

Red

Scanner is on.

Green

A bar code is successfully decoded.