Page 159
Parameter Menus
Intercharacter Delay Parameter # 6Eh The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select the intercharacter delay option matching host requirements. The delay period can range from no delay to 99 msec in 1 msec increments. After scanning the bar code below, scan two bar codes beginning on page 7-105 to set the desired time-out. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 7-107.
Intercharacter Delay
Host Serial Response Time-out Parameter # 9Bh This parameter specifies how long the decoder waits for an ACK or NAK before resending. Also, if the decoder wants to send, and the host has already been granted permission to send, the decoder waits for the designated time-out before declaring an error. The delay period can range from 0.0 to 9.9 seconds in 0.1 second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 7-105. Time durations of less than 1.0 second require a leading zero. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 7-107.
Host Serial Response Time-out
7-99
Page 160
MS-804FZY and MS-904HS Integration Guide
Host Character Time-out Parameter # EFh This parameter determines the maximum time the decoder waits between characters transmitted by the host before discarding the received data and declaring an error. The time-out is set in 0.01 second increments from 0.01 seconds to 0.99 seconds. After scanning the bar code below, scan two bar codes beginning on page 7-105 to set the desired time-out. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 7-107.
Host Character Time-out
7-100
Page 161
Parameter Menus
Event Reporting The host can request the decoder to provide certain information (events) relative to the decoder’s behavior. Enable or disable the events listed in Table 7-3 by scanning the appropriate bar codes on the following pages. Parameter number format for these parameters follows those shown in the Simple Serial Interface (SSI) Programmer’s Guide for parameters numbered 256 or higher. Table 7-3. Event Codes Event Class
Event
Code Reported
Decode Event
Non parameter decode
01h
Boot Up Event
System power-up
03h
Parameter Event
Parameter entry error 07h Parameter stored 08h Defaults set (and parameter event is enabled by default) 0Ah Number expected 0Fh
7-101
Page 162
MS-804FZY and MS-904HS Integration Guide
Decode Event Parameter # F0h 00h When enabled, the scanner sends a message to the host whenever a bar code is successfully decoded. When disabled, no message is sent.
Enable (01h)
*Disable (00h)
7-102
Page 163
Parameter Menus
Boot Up Event Parameter # F0h 02h When enabled, the sends a message a message to the host whenever power is applied. When disabled, no message is sent.
Enable (01h)
*Disable (00h)
7-103
Page 164
MS-804FZY and MS-904HS Integration Guide
Parameter Event Parameter # F0h 03h When enabled, the scanner sends a message to the host when one of the events specified in Table 7-3 on page 7-101 occurs. When disabled, no message is sent.
Enable (01h)
*Disable (00h)
7-104
Page 165
Parameter Menus
Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
0
1
2
3
7-105
Page 166
ee | | MS-804FZY and MS-904HS Integration Guide (| ==
Numeric Bar Codes (continued)
4
5
6
7
7-106
Page 167
Parameter Menus
Numeric Bar Codes (continued)
8
9
Cancel To change a selection or cancel an incorrect entry, scan the bar code below.
Cancel
7-107
Page 168
MS-804FZY and MS-904HS Integration Guide
7-108