Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 23

MiniScan MS-804FZY and MS-904HS Integration Guide, pages 149 to 158

Pages 149 to 158 of 184

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-804FZY and Symbol MS-904HS

Page 149

Parameter Menus

Scan Data Transmission Format (continued)

<PREFIX> <DATA > (04h)

<PREFIX> <DATA> <SUFFIX 1> (05h)

<PREFIX> <DATA> <SUFFIX 2> (06h)

<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)

7-89

Page 150

MS-804FZY and MS-904HS Integration Guide

Simple Serial Interface (SSI) Options Baud Rate Parameter # 9Ch Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Baud Rate 300 (01h)

Baud Rate 600 (02h)

Baud Rate 1200 (03h)

Baud Rate 2400 (04h)

7-90

Page 151

Parameter Menus

Baud Rate (continued)

Baud Rate 4800 (05h)

*Baud Rate 9600 (06h)

Baud Rate 19,200 (07h)

38,400 (08h)

7-91

Page 152

MS-804FZY and MS-904HS Integration Guide

Parity Parameter # 9Eh A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. If you select Odd parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits is contained in the coded character.

Odd (00h)

If you select Even parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits is contained in the coded character.

Even (01h)

7-92

Page 153

Parameter Menus

Parity (continued) Select Mark parity and the parity bit is always 1.

Mark (02h)

Select Space parity and the parity bit is always 0.

Space (03h)

If no parity is required, select None.

*None (04h)

7-93

Page 154

MS-804FZY and MS-904HS Integration Guide

Check Parity Parameter # 97h Select whether or not to check the parity of received characters. Select the type of parity through the Parity parameter.

*Check Parity (01h)

Do Not Check Parity (00h)

7-94

Page 155

Parameter Menus

Software Handshaking Parameter # 9Fh This parameter offers control of the data transmission process in addition to that offered by hardware handshaking. Hardware handshaking is always enabled and cannot be disabled by the user.

Disable ACK/NAK Handshaking When this option is selected, the decoder neither generates nor expects ACK/NAK handshaking packets.

Disable ACK/NAK (00h)

Enable ACK/NAK Handshaking When this option is selected, after transmitting data, the scanner expects either an ACK or NAK response from the host. The scanner also ACKs or NAKs messages from the host. The scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the scanner does not get a response in this time, it resends its data up to two times before discarding the data and declaring a transmit error.

*Enable ACK/NAK (01h)

7-95

Page 156

MS-804FZY and MS-904HS Integration Guide

Host RTS Line State Parameter # 9Ah This parameter is used to set the idle state of the Serial Host RTS line. The SSI Interface is intended to be used with host applications which also implement the SSI protocol. However, the scanner can be used in a "scan-and-transmit" mode to communicate with any standard serial communications software on a host PC (see Decode Data Packet Format on page 7-97). If transmission errors occur in this mode, the host PC may be asserting hardware handshaking lines which interfere with the SSI protocol. Scan the HOST: RTS HIGH bar code to address this problem.

*Host: RTS Low (00h)

Host: RTS High (01h)

7-96

Page 157

Parameter Menus

Decode Data Packet Format Parameter # EEh This parameter selects whether decoded data is transmitted in raw format (unpacketed), or transmitted with the packet format as defined by the serial protocol. If the raw format is chosen, ACK/NAK handshaking is automatically disabled for decode data.

*Send Raw Decode Data (00h)

Send Packeted Decode Data (01h)

7-97

Page 158

MS-804FZY and MS-904HS Integration Guide

Stop Bit Select Parameter # 9Dh The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving (host) device for the next character in the serial data stream. Set the number of stop bits (one or two) to match host device requirements.

*1 Stop Bit (01h)

2 Stop Bits (02h)

7-98