Page 69

Parameter Menus

Set Default Parameter Scan this bar code to return all parameters to the values listed in Table 7-1 on page 7-3.

Set All Defaults

7-9

Page 70

MS-804FZY and MS-904HS Integration Guide

Scanning Options Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the appropriate bar code.

Low Frequency (02h)

Medium Frequency (01h)

*High Frequency (00h)

7-10

Page 71

Parameter Menus

Beeper Frequency Adjustment (MS-804FZY Only) Parameter # F0h 91H This parameter adjusts the frequency of the high beeper tone from the nominal 2500 Hz to another frequency matching the resonances of the installation. It is programmable in 10 Hz increments from 1220 Hz to 3770 Hz. To increase the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 7-105 that correspond to the desired frequency adjustment divided by 10. For example, to set the frequency to 3000 Hz (an increase of 500 Hz), scan numeric bar codes 0, 5, 0, corresponding to 50, or (500/10). To decrease the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 7-105 that correspond to the value (256 - desired adjustment/10). For example, to set the frequency to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes 2, 0, 6, corresponding to 206, or (256 - 500/10).

Beeper Frequency Adjustment

7-11

Page 72

MS-804FZY and MS-904HS Integration Guide

Laser On Time Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 7-105 that correspond to the desired on time. Times less than 1.0 second must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 7-107.

Laser On Time

7-12

Page 73

Parameter Menus

Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In Low Power mode, the scanner enters into a low power consumption mode when possible, provided all WAKEUP signals are released. In Continuous On mode, power remains on after each decode attempt.

Continuous On (00h)

*Low Power (01h)

7-13

Page 74

MS-804FZY and MS-904HS Integration Guide

Triggering Modes Parameter # 8Ah •

Level - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a trigger release, a valid decode, or the Laser On Time-out is reached.

•

Pulse - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a valid decode or the Laser On Time-out is reached.

•

Continuous - The laser is always on and decoding.

•

Blinking - This trigger mode is used for triggerless ScanStand operation. Scanning range is reduced in this mode. This mode cannot be used with scanners that support an aim mode.

•

Host - A host command issues the triggering signal. The scanner interprets an actual trigger pull as a Level triggering option.

*Level (00h)

Pulse (02h)

Continuous (04h)

Blinking (07h)

Host (08h)

7-14

Page 75

Parameter Menus

Aiming Mode Parameter # F0h 7Eh For handheld mode only, select an aiming dot to appear for a normal or extended period of time.

*No Aiming Dot (00h)

Aiming Dot Normal (200 ms) Timeout (01h)

Aiming Dot Extended (400 ms) Timeout (02h)

7-15

Page 76

MS-804FZY and MS-904HS Integration Guide

Timeout Between Decodes Timeout Between Decodes, Same Symbol Parameter # 89h When in Continuous triggering mode, this parameter sets the minimum duration of not decoding data before the scanner decodes a second bar code identical to one just decoded. This reduces the risk of accidently scanning the same symbol twice. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended interval is 0.6 seconds.

Timeout Between Decodes, Different Symbol Parameter # 90h This option sets the minimum duration of not decoding data before the scanner decodes a second (different) bar code. This is used in continuous-on mode to prevent the beeper from beeping when a different symbol appears in the scanner’s field of view before the timeout period between decodes expires. This is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds. Select the timeouts between decodes for the same or different symbols. 1. Scan the option bar code you wish to set. 2. Scan two numeric bar codes beginning on page 7-105 which correspond to the desired interval, in 0.1 second increments.

7-16

Page 77

Parameter Menus

To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 7-107.

Timeout Between Decodes The Same Symbol

Timeout Between Decodes Different Symbols

7-17

Page 78

MS-804FZY and MS-904HS Integration Guide

Beep After Good Decode Parameter # 38h Scan this symbol to set the scanner to beep after a good decode.

*Beep After Good Decode (01h)

Scan this symbol to set the scanner not to beep after a good decode. The beeper still operates during parameter menu scanning and indicates error conditions.

Do Not Beep After Good Decode (00h)

7-18