The text of a manual · part 10 of 23
MiniScan MS-804FZY and MS-904HS Integration Guide, pages 59 to 68
Pages 59 to 68 of 184: Chapter 6 Maintenance and Troubleshooting; Chapter 7 Parameter Menus
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-804FZY and Symbol MS-904HS
Page 59
Chapter 6 Maintenance and Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.
Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the scan window with a damp cloth and, if necessary, a non-ammonia based detergent.
6-1
Page 60
MS-804FZY and MS-904HS Integration Guide
Troubleshooting Problem No red LED or nothing happens during a scan attempt.
Possible Cause
Possible Solutions
No power to the scanner.
Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.
Scanner cannot read the bar Interface/power cables are loose. Re-connect loose cables. code. Scanner is not programmed Make sure the scanner is programmed to read the type of bar for the correct bar code type. code to be scanned. Try scanning other bar code(s) and other bar code types.
Laser activates, followed by a beep sequence.
Incorrect communication parameters.
Set the correct communication parameters (baud rate, parity, stop bits, etc.)
Bar code symbol is unreadable.
Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type.
Inappropriately hot environment.
Remove the scanner from the hot environment, and allow it to cool down.
Beeper is configured.
Refer to beeper indications for beeper indication descriptions.
Note: If after performing th ese checks the symbol still does not scan, contact the distributor or call the Symbol Support Center at the telephone number listed on page xi.
6-2
Page 61
Chapter 7 Parameter Menus This chapter describes the programmable parameters, and provides bar codes for programming and hexadecimal equivalents for host download programming. Throughout the programming bar code menus, default values are indicated with asterisks (*).
*North American, Standard USB Keyboard * Indicates Default
Feature/Option
Operational Parameters The MS-804FZY and MS-904HS are shipped with the default settings shown in Table 7-1 on page 7-3. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. There are two ways to change the default values: •
Scan the appropriate bar codes in this chapter. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set All Defaults bar code on page 7-9.
or
7-1
Page 62
MS-804FZY and MS-904HS Integration Guide
•
Download data through the scanner’s serial port using Symbol’s Simple Serial Interface (SSI). Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method.
Default Table Table 7-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any option, scan the appropriate bar code(s).
7-2
Page 63
Parameter Menus
Table 7-1. Default Table Parameter Number
Default
Page Number
All Defaults
7-9
91h
High Frequency
7-10
F07 91h
2500 Hz
7-11
Laser On Time
88h
3.0 sec
7-12
Power Mode
80h
Low Power
7-13
Trigger Mode
8Ah
Level
7-14
Aiming Mode
F0h 7Eh
Disabled
7-15
Time-out Between Same Symbol
89h
1.0 sec
7-16
Time-out Between Different Symbols
90h
0.0 sec
7-16
Beep After Good Decode
38h
Enable
7-18
Transmit “No Decode” Message
5Eh
Disable
7-19
Parameter Scanning
ECh
Enable
7-20
Linear Code Type Security Level
4Eh
1
7-21
Bi-directional Redundancy
43h
Disable
7-23
UPC-A
01h
Enable
7-24
UPC-E
02h
Enable
7-24
UPC-E1
0Ch
Disable
7-26
EAN-8
04h
Enable
7-27
Parameter Set Default Parameter Scanning Options Beeper Tone Beeper Frequency Adjustment (MS-804FZY only)
UPC/EAN
7-3
Page 64
MS-804FZY and MS-904HS Integration Guide
Table 7-1. Default Table (Continued) Parameter Number
Default
Page Number
EAN-13
03h
Enable
7-28
Bookland EAN
53h
Disable
7-29
Decode UPC/EAN Supplementals
10h
Ignore
7-30
Decode UPC/EAN Supplemental Redundancy
50h
7
7-32
Transmit UPC-A Check Digit
28h
Enable
7-33
Transmit UPC-E Check Digit
29h
Enable
7-34
Transmit UPC-E1 Check Digit
2Ah
Enable
7-35
UPC-A Preamble
22h
System Character
7-36
UPC-E Preamble
23h
System Character
7-37
UPC-E1 Preamble
24h
System Character
7-38
Convert UPC-E to A
25h
Disable
7-39
Convert UPC-E1 to A
26h
Disable
7-40
EAN-8 Zero Extend
27h
Disable
7-41
UPC/EAN Security Level
4Dh
0
7-42
Linear UPC/EAN Decode
44h
Disable
7-44
UPC Half Block Stitching
4Ah
Disable
7-45
Code 128
08h
Enable
7-46
UCC/EAN-128
0Eh
Enable
7-47
ISBT 128
54h
Disable
7-48
Parameter
Code 128
7-4
Page 65
Parameter Menus
Table 7-1. Default Table (Continued) Parameter Number
Default
Page Number
Code 39
00h
Enable
7-49
Trioptic Code 39
0Dh
Disable
7-50
Convert Code 39 to Code 32
56h
Disable
7-51
Code 32 Prefix
E7h
Disable
7-52
Set Length(s) for Code 39
12h 13h
MS-804FZY: Length within Range: 02-55 MS-904HS: Length within Range: 04-37
7-53
Code 39 Check Digit Verification
30h
Disable
7-55
Transmit Code 39 Check Digit
2Bh
Disable
7-56
Code 39 Full ASCII Conversion
11h
Disable
7-57
Code 93
09h
Disable
7-58
Set Length(s) for Code 93
1Ah 1Bh
Length within Range: 04-55
7-59
Interleaved 2 of 5
06h
Disable
7-61
Set Length(s) for I 2 of 5
16h 17h
1 Discrete Length: 14
7-62
I 2 of 5 Check Digit Verification
31h
Disable
7-64
Transmit I 2 of 5 Check Digit
2Ch
Disable
7-65
Parameter Code 39
Code 93
Interleaved 2 of 5
7-5
Page 66
MS-804FZY and MS-904HS Integration Guide
Table 7-1. Default Table (Continued) Parameter Number
Default
Page Number
52h
Disable
7-66
Discrete 2 of 5
05h
Disable
7-67
Set Length(s) for D 2 of 5
14h 15h
1 Discrete Length: 12
7-68
Codabar
07h
Disable
7-70
Set Lengths for Codabar
18h 19h
Length within Range: 05-55
7-71
CLSI Editing
36h
Disable
7-73
NOTIS Editing
37h
Disable
7-74
MSI Plessey
0Bh
Disable
7-75
Set Length(s) for MSI Plessey
1Eh 1Fh
MS-804FZY: Length Within Range: 06 - 55 MS-904HS: Length Within Range: 05 - 55
7-76
MSI Plessey Check Digits
32h
One
7-78
Transmit MSI Plessey Check Digit
2Eh
Disable
7-79
MSI Plessey Check Digit Algorithm
33h
Mod 10/Mod 10
7-80
Parameter Convert I 2 of 5 to EAN 13 Discrete 2 of 5
Codabar
MSI Plessey
7-6
Page 67
Parameter Menus
Table 7-1. Default Table (Continued) Parameter
Parameter Number
Default
Page Number
RSS (MS-804FZY Only) RSS-14
0xF0 0x52
Disable
7-81
RSS-Limited
0xF0 0x53
Disable
7-82
RSS-Expanded
0xF0 0x54
Disable
7-83
Transmit Code ID Character
2Dh
None
7-84
Prefix/Suffix Values Prefix Suffix 1 Suffix 2
69h 68h 6Ah
NULL LF CR
Scan Data Transmission Format
EBh
Data as is
7-88
Baud Rate
9Ch
9600
7-90
Parity
9Eh
None
7-92
Check Parity
97h
Enable
7-94
Software Handshaking
9Fh
Enable
7-95
Decode Data Packet Format
EEh
Unpacketed
7-97
Stop Bit Select
9Dh
1
7-98
Intercharacter Delay
6Eh
0
7-99
Host Serial Response Time-out
9Bh
2 sec
7-99
Data Options
7-86
Simple Serial Interface (SSI) Options
7-7
Page 68
MS-804FZY and MS-904HS Integration Guide
Table 7-1. Default Table (Continued) Parameter Number
Default
Page Number
EFh
200 msec
7-100
Decode Event
F0h 00h
Disable
7-102
Boot Up Event
F0h 02h
Disable
7-103
Parameter Event
F0h 03h
Disable
7-104
Parameter Host Character Time-out Event Reporting
7-8