The text of a manual · part 10 of 23

MiniScan MS-804FZY and MS-904HS Integration Guide, pages 59 to 68

Pages 59 to 68 of 184: Chapter 6 Maintenance and Troubleshooting; Chapter 7 Parameter Menus

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-804FZY and Symbol MS-904HS

Page 59

Chapter 6 Maintenance and Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.

Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the scan window with a damp cloth and, if necessary, a non-ammonia based detergent.

6-1

Page 60

MS-804FZY and MS-904HS Integration Guide

Troubleshooting Problem No red LED or nothing happens during a scan attempt.

Possible Cause

Possible Solutions

No power to the scanner.

Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.

Scanner cannot read the bar Interface/power cables are loose. Re-connect loose cables. code. Scanner is not programmed Make sure the scanner is programmed to read the type of bar for the correct bar code type. code to be scanned. Try scanning other bar code(s) and other bar code types.

Laser activates, followed by a beep sequence.

Incorrect communication parameters.

Set the correct communication parameters (baud rate, parity, stop bits, etc.)

Bar code symbol is unreadable.

Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type.

Inappropriately hot environment.

Remove the scanner from the hot environment, and allow it to cool down.

Beeper is configured.

Refer to beeper indications for beeper indication descriptions.

Note: If after performing th ese checks the symbol still does not scan, contact the distributor or call the Symbol Support Center at the telephone number listed on page xi.

6-2

Page 61

Chapter 7 Parameter Menus This chapter describes the programmable parameters, and provides bar codes for programming and hexadecimal equivalents for host download programming. Throughout the programming bar code menus, default values are indicated with asterisks (*).

*North American, Standard USB Keyboard * Indicates Default

Feature/Option

Operational Parameters The MS-804FZY and MS-904HS are shipped with the default settings shown in Table 7-1 on page 7-3. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. There are two ways to change the default values: •

Scan the appropriate bar codes in this chapter. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set All Defaults bar code on page 7-9.

or

7-1

Page 62

MS-804FZY and MS-904HS Integration Guide

•

Download data through the scanner’s serial port using Symbol’s Simple Serial Interface (SSI). Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method.

Default Table Table 7-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any option, scan the appropriate bar code(s).

7-2

Page 63

Parameter Menus

Table 7-1. Default Table Parameter Number

Default

Page Number

All Defaults

7-9

91h

High Frequency

7-10

F07 91h

2500 Hz

7-11

Laser On Time

88h

3.0 sec

7-12

Power Mode

80h

Low Power

7-13

Trigger Mode

8Ah

Level

7-14

Aiming Mode

F0h 7Eh

Disabled

7-15

Time-out Between Same Symbol

89h

1.0 sec

7-16

Time-out Between Different Symbols

90h

0.0 sec

7-16

Beep After Good Decode

38h

Enable

7-18

Transmit “No Decode” Message

5Eh

Disable

7-19

Parameter Scanning

ECh

Enable

7-20

Linear Code Type Security Level

4Eh

1

7-21

Bi-directional Redundancy

43h

Disable

7-23

UPC-A

01h

Enable

7-24

UPC-E

02h

Enable

7-24

UPC-E1

0Ch

Disable

7-26

EAN-8

04h

Enable

7-27

Parameter Set Default Parameter Scanning Options Beeper Tone Beeper Frequency Adjustment (MS-804FZY only)

UPC/EAN

7-3

Page 64

MS-804FZY and MS-904HS Integration Guide

Table 7-1. Default Table (Continued) Parameter Number

Default

Page Number

EAN-13

03h

Enable

7-28

Bookland EAN

53h

Disable

7-29

Decode UPC/EAN Supplementals

10h

Ignore

7-30

Decode UPC/EAN Supplemental Redundancy

50h

7

7-32

Transmit UPC-A Check Digit

28h

Enable

7-33

Transmit UPC-E Check Digit

29h

Enable

7-34

Transmit UPC-E1 Check Digit

2Ah

Enable

7-35

UPC-A Preamble

22h

System Character

7-36

UPC-E Preamble

23h

System Character

7-37

UPC-E1 Preamble

24h

System Character

7-38

Convert UPC-E to A

25h

Disable

7-39

Convert UPC-E1 to A

26h

Disable

7-40

EAN-8 Zero Extend

27h

Disable

7-41

UPC/EAN Security Level

4Dh

0

7-42

Linear UPC/EAN Decode

44h

Disable

7-44

UPC Half Block Stitching

4Ah

Disable

7-45

Code 128

08h

Enable

7-46

UCC/EAN-128

0Eh

Enable

7-47

ISBT 128

54h

Disable

7-48

Parameter

Code 128

7-4

Page 65

Parameter Menus

Table 7-1. Default Table (Continued) Parameter Number

Default

Page Number

Code 39

00h

Enable

7-49

Trioptic Code 39

0Dh

Disable

7-50

Convert Code 39 to Code 32

56h

Disable

7-51

Code 32 Prefix

E7h

Disable

7-52

Set Length(s) for Code 39

12h 13h

MS-804FZY: Length within Range: 02-55 MS-904HS: Length within Range: 04-37

7-53

Code 39 Check Digit Verification

30h

Disable

7-55

Transmit Code 39 Check Digit

2Bh

Disable

7-56

Code 39 Full ASCII Conversion

11h

Disable

7-57

Code 93

09h

Disable

7-58

Set Length(s) for Code 93

1Ah 1Bh

Length within Range: 04-55

7-59

Interleaved 2 of 5

06h

Disable

7-61

Set Length(s) for I 2 of 5

16h 17h

1 Discrete Length: 14

7-62

I 2 of 5 Check Digit Verification

31h

Disable

7-64

Transmit I 2 of 5 Check Digit

2Ch

Disable

7-65

Parameter Code 39

Code 93

Interleaved 2 of 5

7-5

Page 66

MS-804FZY and MS-904HS Integration Guide

Table 7-1. Default Table (Continued) Parameter Number

Default

Page Number

52h

Disable

7-66

Discrete 2 of 5

05h

Disable

7-67

Set Length(s) for D 2 of 5

14h 15h

1 Discrete Length: 12

7-68

Codabar

07h

Disable

7-70

Set Lengths for Codabar

18h 19h

Length within Range: 05-55

7-71

CLSI Editing

36h

Disable

7-73

NOTIS Editing

37h

Disable

7-74

MSI Plessey

0Bh

Disable

7-75

Set Length(s) for MSI Plessey

1Eh 1Fh

MS-804FZY: Length Within Range: 06 - 55 MS-904HS: Length Within Range: 05 - 55

7-76

MSI Plessey Check Digits

32h

One

7-78

Transmit MSI Plessey Check Digit

2Eh

Disable

7-79

MSI Plessey Check Digit Algorithm

33h

Mod 10/Mod 10

7-80

Parameter Convert I 2 of 5 to EAN 13 Discrete 2 of 5

Codabar

MSI Plessey

7-6

Page 67

Parameter Menus

Table 7-1. Default Table (Continued) Parameter

Parameter Number

Default

Page Number

RSS (MS-804FZY Only) RSS-14

0xF0 0x52

Disable

7-81

RSS-Limited

0xF0 0x53

Disable

7-82

RSS-Expanded

0xF0 0x54

Disable

7-83

Transmit Code ID Character

2Dh

None

7-84

Prefix/Suffix Values Prefix Suffix 1 Suffix 2

69h 68h 6Ah

NULL LF CR

Scan Data Transmission Format

EBh

Data as is

7-88

Baud Rate

9Ch

9600

7-90

Parity

9Eh

None

7-92

Check Parity

97h

Enable

7-94

Software Handshaking

9Fh

Enable

7-95

Decode Data Packet Format

EEh

Unpacketed

7-97

Stop Bit Select

9Dh

1

7-98

Intercharacter Delay

6Eh

0

7-99

Host Serial Response Time-out

9Bh

2 sec

7-99

Data Options

7-86

Simple Serial Interface (SSI) Options

7-7

Page 68

MS-804FZY and MS-904HS Integration Guide

Table 7-1. Default Table (Continued) Parameter Number

Default

Page Number

EFh

200 msec

7-100

Decode Event

F0h 00h

Disable

7-102

Boot Up Event

F0h 02h

Disable

7-103

Parameter Event

F0h 03h

Disable

7-104

Parameter Host Character Time-out Event Reporting

7-8