Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 39

Symbol MS4404/MS4407 Integration Guide: Installation

Pages 25 to 34 of 310, from Symbol MS4404/MS4407 Integration Guide

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-4407

Page 25

Chapter 2 Installation Overview This chapter provides information on unpacking, mounting, and installing the MiniScan imager.

Unpacking Remove the MiniScan from its packing and inspect for damage. If the imager is damaged, call Motorola Enterprise Mobility Support on page xv. KEEP THE PACKING. It is the approved shipping container and should be used if the equipment needs to be returned for servicing.

Page 26

2-2

Symbol MS4404/MS4407 Integration Guide

Mounting There are two mounting holes (threaded inserts) on the bottom of the Symbol MS440X chassis. The following figures provide mounting dimensions for the MiniScan housings. For a mounting template, see Chapter 13, Mounting Template.

NOTE

Use only non-magnetic M3x.5 screws with a maximum length of 3.6mm to mount the MiniScan imager chassis.

Symbol MS440X Mounting Dimensions

Note: Dimensions are in inches [mm] Exit Window Figure 2-1 Symbol MS440X Mounting Dimensions

Page 27

Getting Started

Connecting the MiniScan To connect the MiniScan to the host, connect the imager cables in the order shown in Figure 2-2. To Host 3

4

5

1 Trigger Jack (Optional) See Figure 2-3

Trigger or Photo Sensor (Optional)

2

Figure 2-2 Typical Connection Diagram

Male jack shown for reference

Insertion Direction

1

1 2 3

2 3 Note: Due to many variations of jack and socket styles, identify terminals as shown before soldering leads.

1 -1Ground - Ground(Sleeve) (Sleeve) 2 -2Vcc (Middle Contact) - Battery (Middle Contact) - Trigger(Tip) (Tip) 3 -3Trigger

Figure 2-3 Trigger Jack Connector Pins

2-3

Page 28

2-4

Symbol MS4404/MS4407 Integration Guide

Location and Positioning The location and positioning guidelines provided do not consider unique application characteristics. It is recommended that an opto-mechanical engineer perform an opto-mechanical analysis prior to integration. NOTE

Integrate the imager in an environment no more extreme than the product’s specification, where the imager will not exceed its temperature range. For instance, do not mount the imager onto or next to a large heat source. When placing the imager with another device, ensure there is proper convection or venting for heat. Follow these suggestions to ensure product longevity, warranty, and overall satisfaction with the imager.

Embedded Applications Requiring a Window Use the following guidelines for applications that require a window in front of the MiniScan. NOTE

Motorola does not recommend placing an exit window in front of the MiniScan; however, the following information is provided for applications that require such a window.

Window Material NOTE

The window placement and material recommendations that follow should be considered if the Symbol MS440X is mounted within a product with its own window.

Many window materials that look perfectly clear can contain stresses and distortions that can reduce imager performance. For this reason, optical glass or cell-cast acrylic with an anti-reflection coating is highly recommended. Following is a description of acrylic, and CR-39, another popular window material. Table 2-1 outlines the suggested window properties.

CAUTION

NOTE

Consult an opto-mechanical engineer to recommend an appropriate window material and to determine if coatings are appropriate for the specific application.

Do not use polycarbonate material.

Acrylic When fabricated by cell-casting, acrylic has very good optical quality and low initial cost. However, protect the surface from the environment as acrylic is susceptible to attack by chemicals, mechanical stresses, and UV light. Acrylic has reasonably good impact resistance and can be ultrasonically welded.

CR-39 CR-39 is a thermal-setting plastic produced by the cell-casting process, and is commonly used in plastic eye glasses lenses. CR-39 has excellent chemical and environmental resistance, including good surface hardness. Typically it does not require hard-coating, but can be hard coated for severe environments. CR-39 has reasonably good impact resistance and cannot be ultrasonically welded.

Page 29

Getting Started

2-5

Chemically Tempered Float Glass Glass is a hard material which provides excellent scratch and abrasion resistance. However, unannealed glass is brittle. Increasing flexibility strength with minimal optical distortion requires chemical tempering. Glass cannot be ultrasonically welded and is difficult to cut into odd shapes. Table 2-1 Suggested Window Properties

Property

Description

Material

Clear cell-cast acrylic.

Spectral Transmission

85% minimum from 640 to 690 nanometers.

Thickness

0.059 ± 0.005

Wavefront Distortion (transmission)

0.2 wavelengths peak-to-valley maximum over any 0.08 in. diameter within the clear aperture.

Clear Aperture

To extend to within 0.04 in. of the edges all around.

Surface Quality

60-20 scratch/dig

Coating

Both sides to be anti-reflection coated to provide 0.5% max reflectivity (each side) from 640 to 690 nanometers at nominal window tilt angle. Coatings must comply with the hardness adherence requirements of MIL-M-13508.

Window Coatings Table 2-2 lists some exit window manufacturers and anti-reflection coaters.

Anti-Reflection Coatings Apply an anti-reflection coating to the inside and/or outside of the window to significantly reduce the amount of light reflected off the window, back into the imager engine. The coating can also improve the range of acceptable window positions and minimize performance degradation due to signal loss as the light passes through the window. Using anti-reflection coatings on both the inside and outside of the window is highly recommended.

Page 30

2-6

Symbol MS4404/MS4407 Integration Guide

Polysiloxane Coating Polysiloxane type coatings are applied to plastic surfaces to improve the surface resistance to both scratch and abrasion. They are usually applied by dipping, then air-drying in an oven with filtered hot air. Table 2-2 Window Manufacturers and Coaters

Company

Discipline

Specifics

Evaporated Coatings, Inc. 2365 Maryland Road Willow Grove, PA 19090 (215) 659-3080

Anti-reflection coater

Acrylic window supplier Anti-reflection coater

Fosta-Tek Optics, Inc. 320 Hamilton Street Leominster, MA 01453 (978) 534-6511

Cell-caster, hard coater, laser cutter

CR39 exit window manufacturer

Glasflex Corporation 4 Sterling Road Sterling, NJ 07980 (908) 647-4100

Cell-caster

Acrylic exit window manufacturer

Optical Polymers Int. (OPI) 110 West Main Street Milford, CT 06460 (203) 882-9093

CR-39 cell-caster, coater, laser cutter

CR39 exit window manufacturer

Polycast 70 Carlisle Place Stamford, CT 06902 (800) 243-9002 acrylic cell-caster, hard coater, laser cutter

Acrylic exit window manufacturer

TSP 2009 Glen Parkway Batavia, OH 45103 (800) 277-9778 acrylic cell-caster, coater, laser cutter

Acrylic exit window manufacturer

Embedded Window Angle and Position If a window is placed between the MiniScan and the item to be imaged, observe the following guidelines:

• Window Clear Opening - Make the clear opening of the window large enough so that the entire imager field of view passes through the window. Cutting off any part of the field of view can degrade decode range performance. Ensure that window placement relative to the MiniScan accounts for tolerances on all parts involved in that assembly. •

Window Angle - Angle the window at least 2o more than the tilt of the window on the imager (see Table 2-3). Further tilting the window is acceptable and decreases the possibility of a secondary reflection from that window degrading the imager's performance.

•

Optical Working Range - Adding a window can reduce the working range of the imager since there is a signal loss when passing through window material. To minimize this reduction, use a special coating described in Window Coatings on page 2-5. To understand the difference, test the imager in the desired orientation and see if the difference affects imager performance.

Page 31

Getting Started

Table 2-3 Secondary Window Angles

MiniScan Model

MS4404/MS4407

MiniScan Exit Window Angle from Vertical

Minimum Secondary Window Angle from Vertical (distance > 2 mm)

0.5o

35o

Notes: Unless otherwise specified: • Dimensions are in inches, dimensions in [ ] are mm. • User mounting tolerances are not included. Figure 2-4 Symbol MS440X Optical Path and Exit Window

2-7

Page 32

2-8

Symbol MS4404/MS4407 Integration Guide

Accessories The following accessories are available for the MiniScan imager, and can be found in Symbol’s Solution Builder (ordering guide). Table 2-4 MiniScan Imager Accessories

Accessory

Standard Part Number

ROHS Part Number

Power Supplies*

110V power supply, US

50-14000-008

50-14000-008R

220V power supply, Europe

50-14000-009

50-14000-009R

100V power supply, Asia

50-14000-010

50-14000-010R

264V Universal power supply (also order cables below)

50-14001-001

50-14001-001R

DC line cord (power supply to imager)

50-16002-009

50-16002-009R

AC line cord (wall outlet to power supply)

23844-00-00

N/A

Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and no beeper

25-13227-XX

25-13227-XXR

Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and beeper*

25-13228-XX

25-13228-XXR

Female DB9 with straight connector to RS-232 host (female DB9)

25-58918-XX

25-58918-XXR

Female DB9 with straight connector to RS-232 host (female DB9), with trigger jack and no hardware handshaking

25-63736-XX

25-63736-XXR

Female DB9 with straight connector with trigger jack and beeper to USB (Type A connector)

25-58925-XX

25-58925-XXR

Female DB9 straight to USB

25-58926-XX

25-58926-XXR

Female 25 pin D, TxD on pin 2

50-12100-378

N/A

Female 25 pin D, TxD on pin 3

50-12100-377

N/A

Male 25 pin D, TxD on pin 2

50-12100-380

N/A

Male 25 pin D, TxD on pin 3

50-12100-379

N/A

RS-232

USB

Cable Adapters

*For power connection, this device must be connected to a limited power source. Note: DO NOT use cables with an integrated beeper when operating at 12 VDC.

Page 33

Getting Started

2-9

Table 2-4 MiniScan Imager Accessories (Continued)

Accessory

Standard Part Number

ROHS Part Number

Optional Accessories

Push button trigger cable

25-04950-XX

N/A

Photo sensor trigger cable

25-13176-XX

N/A

SW-60371-XX

N/A

Software

Software Developer's CD

*For power connection, this device must be connected to a limited power source. Note: DO NOT use cables with an integrated beeper when operating at 12 VDC.

Software Developer CD (Symbol MS4404 Only) The Software Developer CD provides the software tools required to integrate and communicate with the MiniScan imagers, including: •

Sample Windows® program with source code

•

DLL with source code for building user applications

•

ActiveX component (including help file) for easy integration into VisualBasic programs

•

Simple Serial Interface documentation.

With over 70 programmable parameters, you can configure MiniScan imagers using bar code menus, or through the serial interface using Symbol’s Simple Serial Interface protocol. For Windows®, DOS, and embedded system environments, the CD enables the user to take full advantage of the imager’s features and obtain maximum performance.

Page 34