Page 19

Chapter 1 Getting Started Overview

CAUTION

Use of controls, adjustments or procedures other than those specified here can result in hazardous laser light exposure.

The Symbol MS440X fixed-mount imager is specifically designed for stand-alone applications, and OEM applications such as kiosks. The imager is extremely compact, provides easy and flexible integration of bar code imaging into a host device, and offers high-performance imaging on 1-D and 2-D bar codes. The Symbol MS440X is ideal for medical instruments and manufacturing applications.

Figure 1-1 Symbol MS440X MiniScan Imager

This integration guide includes parameters and describes the theory of operation, installation, specifications, and configuration.

Page 20

1-2

Symbol MS4404/MS4407 Integration Guide

Symbol MS440X Features • Stand-alone or OEM applications • Quick and easy integration for OEM devices • Excellent imaging performance on all 1-D and 2-D bar codes • RS-232 (Serial) or USB Interface • Direct part mark (DPM) support (DPM version only). Scan 2D symbols etched directly onto an item’s surface (via laser etching and dot peening) for permanent identification.

• Easy programming and configuration • Flexible mounting options •

LEDs indicating power status and successful decodes.

Typical Applications Fixed Mount Standalone Applications

• Clinical diagnostics • Medical instruments • Work stations •

Assembly lines.

OEM Applications

• Kiosks / ATMs • Music listening stations • Medical instruments • Clinical diagnostics • Lottery terminals / gaming •

Airline gate check-in.

Theory of Operation During image capture: 1.

The imager sensor array contained in the SE4400 captures the image of the bar code through the optical system.

2.

The PL4407 controls the SE4400 imager to obtain the best possible image quality.

3.

The PL4407 transfers the decoded data or image data to the host system.

The result is a monochrome digital image similar to that of a digital camera. The output from the SE4400 is byte wide pixel data that is sent to the PL4407.

Page 21

Getting Started

Block Diagrams The MiniScan block diagrams illustrate the functional relationship of the MiniScan components. A detailed description of each component in the block diagrams is also provided.

Block Diagrams

Interface Board Voltage Regulator

Beeper DB9

External Beeper

PL4407 Decoder

Interface Circuit

Red/ Green LED External Trigger

Figure 1-2 Symbol MS4404 Block Diagram

LED Illumination flex

SE4400 (Imager) Data Acquisition Engine

1-3

Page 22

1-4

Symbol MS4404/MS4407 Integration Guide

. Interface Board

Beeper External Beeper DB9

PL4407 Decoder

Red/ Green LED flex

SE4400 (Imager) Data Acquisition Engine

External Trigger

Interface Circuit

LED Illumination

Figure 1-3 Symbol MS4407 Block Diagram

Miniscan Block Diagram Descriptions Imager Engine - The SE4400 engine provides digital images which can be transmitted to a decoder to decode a bar code of any format supported by the decoding software. The engine utilizes laser aiming and an LED illumination system, and can switch between two focus positions for extended working range or for more precise focusing in high-density bar code decoding or digital picture taking. Interface Board - The interface board adapts the imager engine's interface into usable signals and data for the host. It also contains a beeper. LED illumination and red/green LED for audio/visual feedback, and provides for an external trigger and external beeper. The Symbol MS4404 interface board converts TTL level SSI signals to proper RS-232 levels for connection to any RS-232 compliant host, and the Symbol MS4407 interface board allows connection to logic level serial and USB hosts. Voltage Regulator (Symbol MS4404 only) - The power supply allows the Symbol MS4404 to operate of the extended input voltages of 5 - 12 Vdc. DB9 - The DB9 connector provides an outlet for the various interface signals used between a MiniScan and the host. It also maintains pin compatibility with MiniScan (MSXXXX) host cables.

Page 23

Getting Started

1-5

PL4407 Decoder ARM9-Based Processor The digital system is built on an ARM9 Harvard architecture core, 32 bit RISC engine with a five-stage pipeline. The major features of the core are:

• Programmable speed up to 150 MHz with an adjustable external bus speed up to 96 MHz. • 16K instruction and data cache (64-way set associative). • Flexible internal bus architecture that supports DMA operations from any peripheral module to the core or to another peripheral port including main memory. •

Implementation of an enhanced Memory Management Unit (MMU).

Main Memory The two available PL4407 microprocessor designs are:

• PL4407-x100: 32-bit external bus interface to 8 MB of PC100-compliant SDRAM, classified as Mobile SDRAM due to its lower operating current and enhanced power-down modes; internally configured as 4 banks of 512 kb x 32 bits.

• PL4407-x200: 32-bit external bus interface to 16 MB of Mobile SDRAM; internally configured as 4 banks of 1024 Kb x 32 bits.

Power Management (Symbol MS4404 Only) NOTE

This section does not apply to the USB interface. USB supports low power mode as defined by the USB specification.

The Symbol MS4404 has two power modes:

• Continuous Power •

Low Power.

In Continuous Power mode, the Symbol MS4404 system is always running even when not in a decode session. In Low Power mode (the default power mode), the Symbol MS4404 draw less current than when in Continuous Power mode, and is more suitable for battery-powered applications. In this mode the Symbol MS4404 enter Low Power mode whenever possible. The Symbol MS4404 must be awakened from Low Power mode before performing any functions.

Page 24

1-6

Symbol MS4404/MS4407 Integration Guide

Table 1-1 describes how to put the Symbol MS4404 into Low Power mode; Table 1-2 describes how to awaken it. Completely removing power from the Symbol MS4404 is not recommended; this should not be necessary as in Low Power mode the Symbol MS4404 consume very little power (see Table 1-1). Table 1-1 Placing the Symbol MS4404 into Low Power Mode

Action

Behavior

Set the Power Mode parameter to Low Power (see Power Mode on page 6-8).

The Symbol MS4404 enters Low Power mode automatically whenever possible.

Send the serial SLEEP command (see the Simple Serial Interface (SSI) Programmer Guide).

The Symbol MS4404 enters Low Power mode only once, as soon as possible.

Note: All Wake Up signals (see Table 1-2) must be inactive to enter Low Power mode. Once the Symbol MS4404 is awakened, at least 1 second (programmable time) must elapse before it re-enters Low Power mode.

Table 1-2 Waking Up the Symbol MS4404

Signal

State to Wake Up

AIM/WKUP*

Low

TRIG*

Low

CTS*

Low

RXD

Send 0x00

When the Symbol MS4404 is awakened, it remains awake for at least 1 second (programmable time) before re-entering Low Power mode; the host must perform its first action within this time period.

Serial I/O Simple Serial Interface (SSI) Protocol is a half-duplex asynchronous serial interface with two hardware handshaking lines. The four SSI-specific interface signals are:

• TXD - Transmitted Data • RXD - Received Data • RTS* - Request to Send •

CTS* - Clear to Send

Signal names with the "*" modifier are asserted when at the positive logic 0 state (active low). Signal names without the "*" modifier are asserted when at the positive logic 1 state (active high). The TXD line transmits asynchronous serial data from the Symbol MS440X to the host. The RXD line is used by the Symbol MS440X to receive asynchronous serial data from the host. The SSI protocol does not support full-duplex data transfers; data is either transmitted or received by the Symbol MS440X, but never both simultaneously. The RTS* and CTS* signals help coordinate data transfers between the Symbol MS440X and the host.