Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 31 of 39

Symbol MS4404/MS4407 Integration Guide: Miscellaneous Imager Options

Pages 239 to 246 of 310, from Symbol MS4404/MS4407 Integration Guide

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MS-4407

Page 239

Chapter 12 Miscellaneous Imager Options Introduction This chapter includes commonly used bar codes to customize how data is transmitted to the host device. The imager ships with the settings shown in the Miscellaneous Imager Options Default Table on page 12-2 (also see Appendix A, Standard Defaults for all host device and miscellaneous imager defaults). If the default values suit requirements, programming is not necessary. There are two ways to change a parameter value:

• Capture the appropriate bar codes in this guide. These new values replace the standard default values in memory.

• For SSI and USB SNAPI hosts, send a “parameter send” command from the host system. Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer Guide for detailed instructions for changing parameter values using this method. NOTE

Most computer monitors allow capturing the bar codes directly on the screen. When capturing from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.

To return all features to default values, capture *Set All Defaults on page 6-3. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*Disable No Read

Feature/Option

(00h) Hex Value

Imaging Sequence Examples In most cases, capture one bar code to set a specific parameter value. Other parameters, such as Prefix Value, require capturing several bar codes. See each parameter for descriptions of this procedure.

Page 240

12 - 2 Symbol MS4404/MS4407 Integration Guide

Errors While Imaging Unless otherwise specified, to correct an error during an imaging sequence, just re-capture the correct parameter.

Miscellaneous Imager Parameter Defaults Table 12-1 lists the defaults for miscellaneous imager options. To change any option, capture the appropriate bar code(s) provided in the Miscellaneous Imager Parameters on page 12-3. NOTE

Table 12-1

See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Miscellaneous Imager Options Default Table Parameter

Parameter Number

Default

Page Number

Transmit Code ID Character

2Dh

None

12-3

SSI Prefix Value

69h

<CR>

12-4

SSI Suffix 1 Value SSI Suffix 2 Value

68h 6Ah

<CR> <CR>

12-4

Non-SSI Prefix Value

63h, 69h

<CR><LF>

12-4

Non-SSI Suffix 1 Value Non-SSI Suffix 2 Value

62h, 68h 64h, 6Ah

<CR><LF> <CR><LF>

12-4

Scan Data Transmission Format

EBh

Data as is

12-5

FN1 Substitution Values

67h, 6Dh

Set

12-6

Transmit “No Read” Message

5Eh

Disable

12-7

Page 241

Miscellaneous Imager Options 12 - 3

Miscellaneous Imager Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a decoded bar code. This is useful when the imager is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-1 and AIM Code Identifiers on page B-3.

Symbol Code ID Character (02h)

AIM Code ID Character (01h)

*None (00h)

Page 242

12 - 4 Symbol MS4404/MS4407 Integration Guide

Prefix/Suffix Values For SSI Hosts: Parameter # P = 69h, S1 = 68h, S2 = 6Ah

For Non-SSI Hosts: Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to decoded data for use in data editing. To set a value for a prefix or suffix, capture a prefix or suffix bar code below, then capture a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E-1 for the four-digit codes. To correct an error or change a selection, capture Cancel on page D-3. NOTE

To use Prefix/Suffix values, first set the Scan Data Transmission Format on page 12-5. For non-SSI hosts, when using host commands to set the prefix or suffix, set the key category parameter to 1, then set the 3-digit decimal value. See Table E-1 on page E-1 for the four-digit codes.

Scan Prefix (07h)

Scan Suffix 1 (06h)

Scan Suffix 2 (08h)

Page 243

Miscellaneous Imager Options 12 - 5

Scan Data Transmission Format Parameter # EBh To change the scan data format, capture one of the following eight bar codes corresponding to the desired format. NOTE

If using this parameter do not use ADF rules to set the prefix/suffix.

To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 12-4.

*Data As Is (00h)

<DATA> <SUFFIX 1> (01h)

<DATA> <SUFFIX 2> (02h)

<DATA> <SUFFIX 1> <SUFFIX 2> (03h)

<PREFIX> <DATA > (04h)

Page 244

12 - 6 Symbol MS4404/MS4407 Integration Guide

Scan Data Transmission Format (continued)

<PREFIX> <DATA> <SUFFIX 1> (05h)

<PREFIX> <DATA> <SUFFIX 2> (06h)

<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)

FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the Appendix E, ASCII Character Sets for the currently installed host interface for the desired value. To select a FN1 substitution value via bar code menus: 1.

Capture the bar code below.

Set FN1 Substitution Value

2.

Look up the keystroke desired for FN1 Substitution in the ASCII Character Set table for the currently installed host interface. Enter the 4-digit ASCII Value by capturing each digit in Appendix D, Numeric Bar Codes.

To correct an error or change the selection, capture Cancel on Cancel on page D-3. To enable FN1 substitution for USB HID keyboard, capture the Enable FN1 Substitution bar code on page 12-6.

Page 245

Miscellaneous Imager Options 12 - 7

Transmit “No Read” Message Parameter # 5Eh Capture a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.

Enable No Read (01h)

*Disable No Read (00h)

Page 246

12 - 8 Symbol MS4404/MS4407 Integration Guide