The text of a manual · part 30 of 39
Symbol MS4404/MS4407 Integration Guide: Symbologies, pages 229 to 238
Pages 229 to 238 of 310, from Symbol MS4404/MS4407 Integration Guide
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-4407
Page 229
Symbologies 11 - 71
QR Inverse Parameter # F1h 4Bh This parameter sets the QR inverse decoder setting. Options are:
• Regular Only - the scanner decodes regular QR bar codes only. • Inverse Only - the scanner decodes inverse QR bar codes only. • Inverse Autodetect - the scanner decodes both regular and inverse QR bar codes.
*Regular (00h)
Inverse Only (01h)
Inverse Autodetect (02h)
Aztec Parameter # F1h 3Eh To enable or disable Aztec, scan the appropriate bar code below.
*Enable Aztec (01h)
Disable Aztec (00h)
Page 230
11 - 72 Symbol MS4404/MS4407 Integration Guide
Aztec Inverse Parameter # F1h 4Dh This parameter sets the Aztec inverse decoder setting. Options are:
• Regular Only - the scanner decodes regular Aztec bar codes only. • Inverse Only - the scanner decodes inverse Aztec bar codes only. • Inverse Autodetect - the scanner decodes both regular and inverse Aztec bar codes.
*Regular (00h)
Inverse Only (01h)
Inverse Autodetect (02h)
Page 231
Symbologies 11 - 73
Redundancy Level Parameter # 4Eh The imager offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the imager’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1 The code types in Table 11-2 must be successfully read twice before being decoded: Table 11-2 Redundancy Level 1
Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Redundancy Level 2 The code types in Table 11-3 must be successfully read twice before being decoded: Table 11-3 Redundancy Level 2
Code Type All
Code Length All
Redundancy Level 3 Code types other than the code types in Table 11-4 must be successfully read twice before being decoded. The following codes must be read three times: Table 11-4 Redundancy Level 3
Code Type
Code Length
MSI Plessey
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar
8 characters or less
Page 232
11 - 74 Symbol MS4404/MS4407 Integration Guide
Redundancy Level 4 The code types in Table 11-5 must be successfully read three times before being decoded: Table 11-5 Redundancy Level 4
Code Type All
Code Length All
*Redundancy Level 1 (01h)
Redundancy Level 2 (02h)
Redundancy Level 3 (03h)
Redundancy Level 4 (04h)
Page 233
Symbologies 11 - 75
Security Level Parameter # 4Dh The imager offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and imager aggressiveness, so choose only that level of security necessary for any given application.
• Security Level 0: This setting allows the imager to operate in its most aggressive state, while providing sufficient security in decoding most “in-spec” bar codes.
• Security Level 1: Select this option if misdecodes occur. This default setting should eliminate most misdecodes.
• Security Level 2: Select this option if Security level 1 fails to eliminate misdecodes. • Security Level 3: If Security Level 2 was selected and misdecodes still occur, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selecting this level of security significantly impairs the decoding ability of the imager. If this level of security is necessary, try to improve the quality of the bar codes.
Security Level 0 (00h)
*Security Level 1 (01h)
Security Level 2 (02h)
Security Level 3 (03h)
Page 234
11 - 76 Symbol MS4404/MS4407 Integration Guide
Intercharacter Gap Size Parameter # F0h, 7Dh The Code 39 and Codabar symbologies have an intercharacter gap that is typically quite small. Due to various bar code-printing technologies, this gap can grow larger than the maximum size allowed, preventing the imager from decoding the symbol. If this problem occurs, capture the Large Intercharacter Gaps parameter to tolerate these out-of-specification bar codes.
*Normal Intercharacter Gaps (06h)
Large Intercharacter Gaps (0Ah)
Report Version Capture the bar code below to report the version of software currently installed in the imager.
Report Software Version
Page 235
Symbologies 11 - 77
Macro PDF Features Macro PDF is a special feature for concatenating multiple PDF symbols into one file. The imager can decode symbols that are encoded with this feature, and can store more than 64 kb of decoded data stored in up to 50 Macro PDF symbols.
CAUTION
When printing, keep each Macro PDF sequence separate, as each sequence has unique identifiers. Do not mix bar codes from several Macro PDF sequences, even if they encode the same data. When capturing Macro PDF sequences, capture the entire Macro PDF sequence without interruption.
Macro PDF User Indications In this mode the imager provides the following feedback. Table 11-6 Macro PDF User Indications
User Captures
Passthrough All Symbols
Transmit Any Symbol in Set
Buffer All Symbols
Beep
T
Beep
T
Beep
T
Last Macro PDF in set
Decode Beep
Y
Decode Beep
Y
Decode Beep
Y
Any Macro PDF in set except last
Decode Beep
Y
Decode Beep
Y
2 Short Low
N
Macro PDF is not in current Set
Decode Beep
Y
2 Long Low
N
2 Long Low
N
Invalid formatted Macro PDF
Decode Beep
Y
2 Long Low
N
2 Long Low
N
Macro PDF from a set has already been captured
Decode Beep
Y
4 Long Low
N
4 Long Low
N
Out of Macro PDF memory
N/A
-
3 Long Low
N
3 Long Low
N
Any non-Macro PDF captured during a set
N/A
-
4 Long Low
N
4 Long Low
N
Flush Macro PDF
Low Hi
N
5 Long Low
N
5 Long Low
Y
Abort Macro PDF
High Low High Low
N
High Low High Low
N
High Low High Low
N
Notes: 1. The beep only sounds if the *BEEPER_ON signal is connected. 2. The column marked T indicates whether the symbol is transmitted to the host. N = No transmission.
Page 236
11 - 78 Symbol MS4404/MS4407 Integration Guide
Macro PDF Transmit / Decode Mode Symbols Parameter # BCh Select one of the options below for handling Macro PDF decoding. In Buffer All Symbols the imager can handle sets of up to 50 maximum-sized Macro PDF symbols. In all other modes there is no limit to the size of the Macro PDF set.
• Buffer All Symbols / Transmit Macro PDF When Complete: This transmits all decode data from an entire Macro PDF sequence only when the entire sequence is captured and decoded. Use the beeper and LED signals provided with the Symbol MS440X when using this mode to ensure proper user feedback. If the decode data exceeds the limit of 50 symbols, there is no transmission because the entire sequence was not decoded. Use the parameter Flush Macro Buffer on page 11-80 to purge the buffer.
• Transmit Any Symbol in Set / No Particular Order: This transmits data from each Macro PDF symbol as decoded, regardless of the sequence (although some error handling is performed; see Table 11-6). When selecting this mode, enable Transmit Macro PDF Control Header on page 11-79. Also use the beeper and LED signals provided with the Symbol MS440X to ensure proper user feedback.
• Passthrough All Symbols: This transmits and decodes all Macro PDF symbols and performs no processing. In this mode the host is responsible for detecting and parsing the Macro PDF sequences. Use this mode when the imager’s BEEPER_ON signal is not used to drive a beeper. In the other modes, some Macro PDF imaging sequences provide audible feedback only, so if BEEPER_ON is not used no user feedback is provided. In Table 11-6, all actions marked No Transmission provide no feedback unless the BEEPER_ON signal is used. By using Passthrough All Symbols mode every user decode is transmitted to the host where the host software can provide the appropriate feedback.
Buffer All Symbols / Transmit Macro PDF When Complete (00h)
Transmit Any Symbol in Set / No Particular Order (01h)
*Passthrough All Symbols (04h)
Page 237
Symbologies 11 - 79
Transmit Macro PDF Control Header Parameter # B8h When enabled, this activates transmission of the control header, which contains the segment index and the file ID, in Macro PDF symbols. For example, the field may be: \92800000\725\120\343. The five digits after the \928 are the segment index (or block index), and \725\120\343 is the file ID. Enable this when selecting Transmit Any Symbol in Set / No Particular Order for the Macro PDF Transmit / Decode Mode Symbols on page 11-78, and disable this when selecting Buffer All Symbols / Transmit Macro PDF When Complete. This parameter has no effect when Passthrough All Symbols is selected.
Enable Macro PDF Control Header Transmit (01h)
*Disable Macro PDF Control Header Transmit (00h)
Escape Characters Parameter # E9h This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Capture a bar code below to either format special data according to the GLI (Global Label Identifier) protocol, or to disable this parameter. This parameter only affects the data portion of a Macro PDF symbol transmission; the Macro PDF Control Header (if enabled) is always sent with GLI formatting.
GLI Protocol (02h)
*None (00h)
Page 238
11 - 80 Symbol MS4404/MS4407 Integration Guide
Flush Macro Buffer This flushes the buffer of all decoded Macro PDF data stored to that point, transmits it to the host device, and aborts from Macro PDF mode.
Flush Macro PDF Buffer
Abort Macro PDF Entry This clears all currently-stored Macro PDF data in the buffer without transmission and aborts from Macro PDF mode.
Abort Macro PDF Entry