Page 227
Parameter Menus
Transmit Unknown Codewords Parameter # BAh Select Transmit Unknown Codewords to use the output codeword format for transmitting any non-GLI or non-macro PDF codeword. Select Do Not Transmit Unknown Codewords to sound a decode error beep when an unknown codeword is found.
Transmit Unknown Codewords (01h)
*Do Not Transmit Unknown Codewords (00h)
10-119
Page 228
MS XX07 Series Integration Guide
Escape Characters Parameter # E9h This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data (e.g., GLI escapes, MacroPDF417 Control Block optional fields) according to the GLI (Global Label Identifier) protocol or the ECI (Extended Channel Interpretation) protocol, or to disable this parameter.
ECI Protocol (01h)
GLI Protocol (02h)
*None (00h)
10-120
Page 229
Parameter Menus
Delete Character Set ECIs Parameter # E6h Select Delete Character Set ECIs to delete any escape sequences representing Character Set ECIs (also known as GLIs) from its buffer before transmission. In many receiving systems, Character Set ECIs can be removed without affecting the way data is displayed or processed. Select Transmit Character Set ECIs to transmit data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. Scan a bar code to delete or transmit character set ECIs.
Delete Character Set ECIs (01h)
*Transmit Character Set ECIs (00h)
10-121
Page 230
MS XX07 Series Integration Guide
ECI Decoder Parameter # E8h This parameter enables the scanner to interpret any Extended Channel Interpretations (ECIs) that are supported by the scanner firmware. This does not affect symbols not encoded using ECIs. This version of the product supports ECIs 000900 through 000913, used for efficient encoding of Common Data Syntax Format 00-99. If this parameter is disabled, and a symbol is scanned that was encoded using an ECI escape, the scanner transmits the ECI escape followed by the uninterpreted data. Scan a bar code to enable or disable this option.
*Enable ECI Decoder (01h)
Disable ECI Decoder (00h)
10-122
Page 231
Parameter Menus
Transmit Macro PDF User-Selected Fields Note: These options are supported by the MS 2207, MS 2207VHD, and MS 3207 only. Enable or disable each of the following parameters to indicate whether or not to transmit the specified field in subsequently scanned Macro PDF417 symbols. The options cannot be changed in the middle of a Macro PDF set entry. All user-selected fields are prefixed by \923 for GLIs, and \C923C for ECIs. Tags and examples in the following parameters demonstrate GLI protocol, but the ECI tag (\C923C) can be used instead if ECI protocol is enabled.
Transmit File Name Parameter # B0h Transmit File Name activates transmission of the file name field. The field character tag is \923\000. For example, the filename MANHOURS.WK1 is sent as: \923\000MANHOURS.WK1.
Enable File Name Transmit (01h)
*Disable File Name Transmit (00h)
10-123
Page 232
MS XX07 Series Integration Guide
Transmit Block Count Parameter # B1h Transmit Block Count activates transmission of the block count field. The field character tag is \923\001. For example, the field may be: \923\0011856.
Enable Transmit Block Count (01h)
*Disable Transmit Block Count (00h)
10-124
Page 233
Parameter Menus
Transmit Time Stamp Parameter # B2h Transmit Time Stamp activates transmission of the time stamp field. The field character tag is \923\002. For example, the field may be: \923\0022123443243234.
Enable Transmit Time Stamp (01h)
*Disable Transmit Time Stamp (00h)
10-125
Page 234
MS XX07 Series Integration Guide
Transmit Sender Parameter # B3h Transmit Sender activates transmission of the sender field. The field character tag is \923\003. For example, the field may be: \923\003Symbol Technologies Holtsville, NY.
Enable Sender Transmit (01h)
*Disable Sender Transmit (00h)
10-126
Page 235
Parameter Menus
Transmit Addressee Parameter # B4h Transmit Addressee activates transmission of the addressee field. The field character tag is \923\004. For example, the field may be: \923\004AIM USA.
Enable Addressee Transmit (01h)
*Disable Addressee Transmit (00h)
10-127
Page 236
MS XX07 Series Integration Guide
Transmit Checksum Parameter # B6h Transmit Checksum activates transmission of the checksum field. The field character tag is \923\006. For example, the field may be: \923\00663823.
Enable Checksum Transmit (01h)
*Disable Checksum Transmit (00h)
10-128