For the Symbol MS-1207

Page 217

Parameter Menus

Prefix/Suffix Values Parameter # P = 69h, S1 = 68h, S2 = 6Ah A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes; see Numeric Bar Codes beginning on page 10-132) that corresponds to that value. See Table A-1 on page A-1 for the four-digit codes. To change the selection or cancel an incorrect entry, scan the Cancel bar code on page 10-134. Note: In order to use Prefix/Suffix values, first set the Scan Data Transmission Format on page 10-111.

10-109

Page 218

MS XX07 Series Integration Guide

Prefix/Suffix Values (continued)

Scan Prefix (07h)

Scan Suffix 1 (06h)

Scan Suffix 2 (08h)

Data Format Cancel

10-110

Page 219

Parameter Menus

Scan Data Transmission Format To change the Scan Data Transmission Format, scan the Scan Options bar code below, then select one of four options: •

Data As Is

•

<DATA> <SUFFIX>

•

<PREFIX> <DATA>

•

<PREFIX> <DATA> <SUFFIX> Note: To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 10-109.

After making a selection, scan the Enter bar code on page 10-112. To change the selection or to cancel an incorrect entry, scan the Data Format Cancel bar code on page 10-112. To add a carriage return/enter after each bar code scanned, scan the following bar codes in order: 1. <SCAN OPTIONS> 2. <DATA> <SUFFIX> 3. Enter (on page 10-112).

Scan Options

*Data As Is

10-111

Page 220

MS XX07 Series Integration Guide

Scan Data Transmission Format (continued)

<DATA> <SUFFIX>

<PREFIX> <DATA>

<PREFIX> <DATA> <SUFFIX>

Enter

Data Format Cancel

10-112

Page 221

Parameter Menus

Event Reporting The host can request the decoder to provide certain information (events) relative to the decoder’s behavior. Enable or disable the events listed in Table 10-3 by scanning the appropriate bar codes on the following pages. Parameter number format for these parameters follows those shown in the Simple Serial Interface (SSI) Programmer’s Guide for parameters numbered 256 or higher. Table 10-3. Event Codes Event Class

Event

Code Reported

Decode Event

Non-parameter decode

01h

Boot Up Event

System power-up

03h

Parameter Event

Parameter entry error 07h Parameter stored 08h Defaults set (and parameter event is enabled by default) 0Ah Number expected 0Fh

10-113

Page 222

MS XX07 Series Integration Guide

Decode Event Parameter # F0h 00h When enabled, the scanner sends a message to the host whenever a bar code is successfully decoded. When disabled, no message is sent.

Enable (01h)

*Disable (00h)

10-114

Page 223

Parameter Menus

Boot Up Event Parameter # F0h 02h When enabled, the sends a message a message to the host whenever power is applied. When disabled, no message is sent.

Enable (01h)

*Disable (00h)

10-115

Page 224

MS XX07 Series Integration Guide

Parameter Event Parameter # F0h 03h When enabled, the scanner sends a message to the host when one of the events specified in Table 10-3 on page 10-113 occurs. When disabled, no message is sent.

Enable (01h)

*Disable (00h)

10-116

Page 225

Parameter Menus

Macro PDF Features Note: These options are supported by the MS 2207, MS 2207VHD, and MS 3207 only.

Transmit Symbols in Codeword Format Parameter # Afh Enable this to transmit each PDF symbol as directly decoded data codewords, whether or not that symbol is part of a macro PDF sequence. Note that data is output as codeword values, not as interpreted data. “Codeword values” is an ASCII representation of a number from 000 to 928 for each codeword, preceded by an escape character. This escape character is a backslash by default, but you can change this value. For example, the codeword value 005 is sent to the host in the form of \005 for GLIs, and \C005C for ECIs. This output format is based on the AIM USA Uniform Symbology Specification for PDF417 (1994). All output codewords are exactly 4 characters for GLIs and 6 characters for ECIs. However, there can be non-decodable characters in the PDF symbol, such as a GLI sequence. This special codeword sequence activates a certain kind of interpretation to the encoded data. Non-decodable codewords like GLIs are embedded in the output stream like any other codeword, e.g., \927\001. Because GLIs are indistinguishable from other codewords in the output data stream, the host must recognize them as GLIs and process their interpretations. Note that when a macro PDF sequence is transmitted, the last character in the last block of data transmitted is always \922 (if selected). This indicates the end of that macro PDF transmission.

10-117

Page 226

MS XX07 Series Integration Guide

Transmit Symbols in Codeword Format (continued) Scan the appropriate bar code to enable or disable this.

Enable Transmit In Codeword Format (01h)

*Disable Transmit In Codeword Format (00h)

10-118