Page 117

Parameter Menus

Table 10-1. Default Table (Continued) Parameter Number

Default

Page Number

Transmit Time Stamp

B2h

Disable

10-125

Transmit Sender

B3h

Disable

10-126

Transmit Addressee

B4h

Disable

10-127

Transmit Checksum

B6h

Disable

10-128

Transmit File Size

B5h

Disable

10-129

Transmit Macro PDF Control Header

B7h

Disable

10-130

Last Block Marker

B9h

Disable

10-131

Parameter

10-9

Page 118

MS XX07 Series Integration Guide

Set Default Parameter Scan this bar code to return all parameters to the values listed in Table 10-1 on page 10-2.

Set All Defaults

10-10

Page 119

Parameter Menus

Scanning Options Beeper Volume Parameter # 8Ch To select a decode beep volume, scan the Low Volume, Medium Volume, or High Volume bar code.

Low Volume

Medium Volume

*High Volume

10-11

Page 120

MS XX07 Series Integration Guide

Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the appropriate bar code.

Low Frequency (02h)

Medium Frequency (01h)

*High Frequency (00h)

10-12

Page 121

Parameter Menus

Beeper Frequency Adjustment Parameter # F0h 91H This parameter adjusts the frequency of the high beeper tone from the nominal 2500 Hz to another frequency matching the resonances of the installation. It is programmable in 10 Hz increments from 1220 Hz to 3770 Hz. To increase the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 10-132 that correspond to the desired frequency adjustment divided by 10. For example, to set the frequency to 3000 Hz (an increase of 500 Hz), scan numeric bar codes 0, 5, 0, corresponding to 50, or (500/10). To decrease the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 10-132 that correspond to the value (256 - desired adjustment/10). For example, to set the frequency to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes 2, 0, 6, corresponding to 206, or (256 - 500/10).

Beeper Frequency Adjustment (Default: 2500 Hz)

10-13

Page 122

MS XX07 Series Integration Guide

Laser On Time Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 10-132 that correspond to the desired on time. Times less than 1.0 second must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 10-134.

Laser On Time

10-14

Page 123

Parameter Menus

Scan Angle Parameter # BFh Note: This option is supported by the MS 1207FZY only. This parameter sets the scan angle to the default or alternate angle.

*Default Angle (06h)

Alternate Angle (05h)

10-15

Page 124

MS XX07 Series Integration Guide

Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In Low Power mode, the scanner enters into a low power consumption mode when possible, provided all WAKEUP signals are released. In Continuous On mode, power remains on after each decode attempt.

Continuous On (00h)

*Low Power (01h)

10-16

Page 125

Parameter Menus

Trigger Mode Parameter # 8Ah •

Level - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a trigger release, a valid decode, or the Laser On Time-out is reached.

•

Pulse - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a valid decode or the Laser On Time-out is reached.

•

Continuous - The laser is always on and decoding.

•

Blink - This trigger mode is used for triggerless ScanStand operation. Scanning range is reduced in this mode. This mode is only supported by MS 1207FZY models.

•

Host - A host command issues the triggering signal. The scanner interprets an actual trigger pull as a Level triggering option.

Level (00h)

Pulse (02h)

*Continuous (04h)

Blink (07h)

Host (08h)

10-17

Page 126

MS XX07 Series Integration Guide

Scanning Mode Parameter # 8Dh Note: These options are supported by the MS 2207, MS 2207VHD, and MS 3207 only. Select one of the following scanning modes: •

Smart Raster

•

Always Raster

•

Slab Only Raster

•

Programmable Raster

•

Omnidirectional (Cyclone) •

Semi-Omnidirectional

Note: If Omnidirectional is selected, disabling the following parameters is recommended: PDF417, MicroPDF417, RSS-Limited, CC-C, CC-AB, TLC-39 and Linear UPC.

* Smart Raster (01h)

Always Raster (02h)

Programmable Raster (03h)

Slab Pattern (04h)

Omnidirectional Pattern (06h)

Semi-Omni Pattern (07h)

10-18