Chapter 9 Maintenance and Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.
Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the scan window with a damp cloth and, if necessary, a non-ammonia based detergent.
Troubleshooting Problem No red LED or nothing happens during a scan attempt.
Possible Cause
Possible Solutions
No power to the scanner.
Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.
9-1
Page 108
MS XX07 Series Integration Guide
Problem
Possible Cause
Possible Solutions
Scanner cannot read the bar Interface/power cables are loose. Re-connect loose cables. code. Scanner is not programmed for Make sure the scanner is the correct bar code type. programmed to read the type of bar code to be scanned. Try scanning other bar code(s) and other bar code types. Incorrect communication parameters.
Set the correct communication parameters (baud rate, parity, stop bits, etc.)
Bar code symbol is unreadable.
Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type.
Inappropriately hot environment.
Remove the scanner from the hot environment, and allow it to cool down.
Laser activates, followed by Beeper is configured. a beep sequence.
Refer to Table 3-1 on page 3-8 for beeper indication descriptions.
Scanner configured to USB host and does not scan.
Unplug scanner from USB host. Present Continuous trigger mode bar code on page 3-6 and plug unit in. Upon power up the scanner scans briefly, decodes, and switches to continuous trigger mode.
Incorrect trigger mode selected.
Note: If after performing these checks the symbol still does not scan, contact the distributor or call the Symbol Support Center at the telephone number listed on page xiii.
9-2
Page 109
Chapter 10 Parameter Menus This chapter describes the programmable parameters, and provides bar codes for programming and hexadecimal equivalents for host download programming. Throughout the programming bar code menus, default values are indicated with asterisks (*).
*Low Power * Indicates Default
Feature/Option
Operational Parameters MiniScan scanners are shipped with the default settings shown in Table 10-1 on page 102. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. To change the default values, scan the appropriate bar codes in this chapter. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set All Defaults bar code on page 10-10.
Default Table Table 10-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any option, scan the appropriate bar code(s).
10-1
Page 110
MS XX07 Series Integration Guide
Table 10-1. Default Table Parameter
Parameter Number
Set Default Parameter
Default
Page Number
All Defaults
10-10
Scanning Options Beeper Volume
8Ch
High Volume
10-11
Beeper Tone
91h
High Frequency
10-12
F0h 91h
2500 Hz
10-13
Laser On Time
88h
MS 120X: 3.0 sec MS 220X/3207: 5.0 sec
10-14
Scan Angle (MS 1207FZY only)
BFh
Wide
10-15
Power Mode
80h
Low Power
10-16
Trigger Mode
8Ah
Continuous
10-17
Scanning Mode (MS 2207, MS 2207VHD, and MS 3207 only)
8Dh
Smart Raster
10-18
F0h 7Eh
Disabled
10-18
Raster Height (MS 2207, MS 2207VHD, and MS 3207 only)
E4h
15
10-20
Raster Expansion Rate (MS 2207, MS 2207VHD, and MS 3207 only)
E5h
11
10-20
Time-out Between Same Symbol
89h
0.6 sec
10-21
Time-out Between Different Symbols
90h
0.0 sec
10-21
Beep After Good Decode
38h
Enable
10-22
Transmit “No Read” Message
5Eh
Disable
10-23
Parameter Scanning
ECh
Enable
10-24
Beeper Frequency Adjustment
Aiming Mode
10-2
Page 111
Parameter Menus
Table 10-1. Default Table (Continued) Parameter
Parameter Number
Linear Code Type Security Levels
4Eh
MS 120X: 1 MS 220X/MS 3207: 2
10-25
Bi-directional Redundancy
43h
Disable
10-27
UPC-A
01h
Enable
10-28
UPC-E
02h
Enable
10-28
UPC-E1
0Ch
Disable
10-30
EAN-8
04h
Enable
10-31
EAN-13
03h
Enable
10-32
Bookland EAN
53h
Disable
10-33
UPC/EAN Coupon Code
55h
Disable
10-34
Decode UPC/EAN Supplementals
10h
Ignore
10-35
Decode UPC/EAN Supplemental Redundancy
50h
20
10-37
Transmit UPC-A Check Digit
28h
Enable
10-38
Transmit UPC-E Check Digit
29h
Enable
10-39
Transmit UPC-E1 Check Digit
2Ah
Enable
10-40
UPC-A Preamble
22h
System Character
10-41
UPC-E Preamble
23h
System Character
10-42
UPC-E1 Preamble
24h
System Character
10-43
Convert UPC-E to A
25h
Disable
10-44
Default
Page Number
UPC/EAN
10-3
Page 112
MS XX07 Series Integration Guide
Table 10-1. Default Table (Continued) Parameter Number
Default
Page Number
Convert UPC-E1 to A
26h
Disable
10-45
EAN-8 Zero Extend
27h
Disable
10-46
UPC/EAN Security Level
4Dh
0
10-47
Linear UPC/EAN Decode
44h
Disable
10-49
UPC Half Block Stitching (MS 2207, MS 2207VHD, and MS 3207 only)
4Ah
Disable
10-50
Code 128
08h
Enable
10-51
UCC/EAN-128
0Eh
Enable
10-52
ISBT 128
54h
MS 120X: Enable MS 220X/MS 3207: Disable
10-53
Code 128 Decode Performance (MS 2207, MS 2207VHD, and MS 3207 only)
48h
Enable
10-54
Code 128 Decode Performance Level (MS 2207, MS 2207VHD, and MS 3207 only)
49h
Level 3
10-55
Code 39
00h
Enable
10-56
Trioptic Code 39
0Dh
Disable
10-57
Convert Code 39 to Code 32
56h
MS 120X/MS 3207: Disable MS 220X: Enable
10-58
Parameter
Code 128
Code 39
10-4
Page 113
Parameter Menus
Table 10-1. Default Table (Continued) Parameter Number
Default
Page Number
Code 32 Prefix
E7h
Enable
10-59
Set Length(s) for Code 39
12h 13h
Length within Range: MS 120X: 2-55 MS 220X/MS 3207: 1-55
10-60
Code 39 Check Digit Verification
30h
Disable
10-62
Transmit Code 39 Check Digit
2Bh
Disable
10-63
Code 39 Full ASCII Conversion
11h
Disable
10-64
Code 39 Decode Performance (MS 2207, MS 2207VHD, and MS 3207 only)
46h
Enable
10-65
Code 39 Decode Performance Level (MS 2207, MS 2207VHD, and MS 3207 only)
47h
Level 3
10-66
Code 93
09h
Disable
10-67
Set Length(s) for Code 93
1Ah 1Bh
Length within Range: 04-55
10-68
0Ah
Disable
10-70
1Ch, 1Dh
Length within Range: 04-55
10-71
Code 11 Check Digit Verification
34h
Disable
10-73
Transmit Code 11 Check Digits
2Fh
Disable
10-74
Parameter
Code 93
Code 11 Code 11 Set Length(s) for Code 11
10-5
Page 114
MS XX07 Series Integration Guide
Table 10-1. Default Table (Continued) Parameter
Parameter Number
Default
Page Number
Interleaved 2 of 5 Interleaved 2 of 5
06h
MS 120X: Enable MS 220X/MS 3207: Disable
10-75
Set Length(s) for I 2 of 5
16h 17h
1 Discrete Length: 14
10-76
I 2 of 5 Check Digit Verification
31h
Disable
10-78
Transmit I 2 of 5 Check Digit
2Ch
Disable
10-79
Convert I 2 of 5 to EAN 13
52h
Disable
10-80
Discrete 2 of 5
05h
Disable
10-81
Set Length(s) for D 2 of 5
14h 15h
1 Discrete Length: 12
10-82
Codabar
07h
Disable
10-84
Set Lengths for Codabar
18h 19h
Length within Range: 05-55
10-85
CLSI Editing
36h
Disable
10-87
NOTIS Editing
37h
Disable
10-88
MSI Plessey
0Bh
Disable
10-89
Set Length(s) for MSI Plessey
1Eh 1Fh
Length Within Range: 06 - 55
10-90
Discrete 2 of 5
Codabar
MSI Plessey
10-6
Page 115
Parameter Menus
Table 10-1. Default Table (Continued) Parameter Number
Default
Page Number
MSI Plessey Check Digits
32h
One
10-92
Transmit MSI Plessey Check Digit
2Eh
Disable
10-93
MSI Plessey Check Digit Algorithm
33h
Mod 10/Mod 10
10-94
Parameter
PDF417/MicroPDF417 (MS 2207, MS 2207VHD, and MS 3207 Only) PDF417
0fh
MS 220X: Enable MS 3207: Disable
10-95
MicroPDF417
E3h
Disable
10-96
MicroPDF Performance
F0h 65h
Standard
10-97
Code 128 Emulation
7Bh
Disable
10-98
RSS-14
F0h 52h
Disable
10-99
RSS Limited
F0h 53h
Disable
10-100
RSS Expanded
F0h 54h
Disable
10-101
Convert RSS to UPC/EAN (MS 1207FZY and MS 1207WA only)
F0h 8Dh
Disable
10-101
RSS
Composite (MS 2207, MS 2207VHD and MS 3207 only) CC-C
F0h 55h
Disable
10-103
CC-AB
F0h 56h
Disable
10-104
TLC-39
F0h 73h
Disable
10-105
UPC Composite Mode
F0h 58h
Always Linked
10-106
10-7
Page 116
MS XX07 Series Integration Guide
Table 10-1. Default Table (Continued) Parameter Number
Default
Page Number
Transmit Code ID Character
2Dh
None
10-107
Prefix/Suffix Values Prefix Suffix 1 Suffix 2
69h 68h 6Ah
NULL CR LF
Scan Data Transmission Format
N/A
Data as is
10-111
Decode Event
F0h 00h
Disable
10-114
Boot Up Event
F0h 02h
Disable
10-115
Parameter Event
F0h 03h
Disable
10-116
Parameter Data Options
10-109
Event Reporting
Macro PDF (MS 2207, MS 2207VHD, and MS 3207 only) Transmit Symbols in Codeword Format
Afh
Disable
10-117
Transmit Unknown Codewords
BAh
Disable
10-119
Escape Character
E9h
None
10-120
ECI (MS 2207, MS 2207VHD, and MS 3207 only) Delete Character Set ECIs
E6h
Enable
10-121
ECI Decoder
E8h
Enable
10-122
Transmit Macro PDF User-Selected Field (MS 2207, MS 2207VHD, and MS 3207 only) Transmit File Name
B0h
Disable
10-123
Transmit Block Count
B1h
Disable
10-124