Page 131

Parameter Menus

Table 11-1. Default Table (Continued) Parameter

Parameter Number

Default

Page Number

Composite (MS 2204, MS 2204VHD and MS 3204 only) CC-C

F0h 55h

Disable

11-105

CC-AB

F0h 56h

Disable

11-106

TLC-39

F0h 73h

Disable

11-107

UPC Composite Mode

F0h 58h

Always Linked

11-108

Transmit Code ID Character

2Dh

None

11-109

Prefix/Suffix Values Prefix Suffix 1 Suffix 2

69h 68h 6Ah

NULL LF CR

Scan Data Transmission Format

EBh

Data as is

11-113

Baud Rate

9Ch

9600

11-115

Parity

9Eh

None

11-117

Check Parity

97h

Enable

11-119

Software Handshaking

9Fh

ACK/NAK

11-120

Host RTS Line State

9Ah

Low

11-121

Decode Data Packet Format

EEh

Unpacketed

11-122

Stop Bit Select

9Dh

1

11-123

Intercharacter Delay

6Eh

0

11-124

Data Options

11-111

Simple Serial Interface (SSI) Options

11-9

Page 132

MS XX04 Series Integration Guide

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

Host Serial Response Time-out

9Bh

2 sec

11-124

Host Character Time-out

EFh

200 msec

11-125

Decode Event

F0h 00h

Disable

11-127

Boot Up Event

F0h 02h

Disable

11-128

Parameter Event

F0h 03h

Disable

11-129

Parameter

Event Reporting

Macro PDF (MS 2204, MS 2204VHD, and MS 3204 only) Transmit Each Symbol in Codeword Format

Afh

Disable

11-130

Transmit Unknown Codewords

BAh

Disable

11-132

Escape Character

E9h

None

11-133

Delete Character Set ECIs

E6h

Enable

11-134

ECI Decoder

E8h

Enable

11-135

ECI (MS 2204, MS 2204VHD and MS 3204 only)

Transmit Macro PDF User-Selected Field (MS 2204, MS 2204VHD, and MS 3204 only) Transmit File Name

B0h

Disable

11-137

Transmit Block Count

B1h

Disable

11-138

Transmit Time Stamp

B2h

Disable

11-139

Transmit Sender

B3h

Disable

11-140

Transmit Addressee

B4h

Disable

11-141

Transmit Checksum

B6h

Disable

11-142

11-10

Page 133

Parameter Menus

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

Transmit File Size

B5h

Disable

11-143

Transmit Macro PDF Control Header

B7h

Disable

11-144

Last Block Marker

B9h

Disable

11-145

Parameter

11-11

Page 134

MS XX04 Series Integration Guide

Set Default Parameter Scan this bar code to return all parameters to the values listed in Table 11-1 on page 11-3.

Set All Defaults

11-12

Page 135

Parameter Menus

Scanning Options Beeper Volume Parameter # 8Ch To select a decode beep volume, scan the Low Volume, Medium Volume, or High Volume bar code.

Low Volume

Medium Volume

*High Volume

11-13

Page 136

MS XX04 Series Integration Guide

Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the appropriate bar code.

Low Frequency (02h)

Medium Frequency (01h)

*High Frequency (00h)

11-14

Page 137

Parameter Menus

Beeper Frequency Adjustment Parameter # F0h 91H Note: This option is not supported by MS 904HS. This parameter adjusts the frequency of the high beeper tone from the nominal 2500 Hz to another frequency matching the resonances of the installation. It is programmable in 10 Hz increments from 1220 Hz to 3770 Hz. To increase the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 11-146 that correspond to the desired frequency adjustment divided by 10. For example, to set the frequency to 3000 Hz (an increase of 500 Hz), scan numeric bar codes 0, 5, 0, corresponding to 50, or (500/10). To decrease the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 11-146 that correspond to the value (256 - desired adjustment/10). For example, to set the frequency to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes 2, 0, 6, corresponding to 206, or (256 - 500/10).

Beeper Frequency Adjustment

11-15

Page 138

MS XX04 Series Integration Guide

Laser On Time Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 11-146 that correspond to the desired on time. Times less than 1.0 second must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 11-148.

Laser On Time

11-16

Page 139

Parameter Menus

Scan Angle Parameter # BFh Note: This option is supported by the MS 1204FZY and MS 804FZY only. This parameter sets the scan angle.

*Default Angle (06h)

Alternate Angle (05h)

11-17

Page 140

MS XX04 Series Integration Guide

Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In Low Power mode, the scanner enters into a low power consumption mode when possible, provided all WAKEUP signals are released. In Continuous On mode, power remains on after each decode attempt.

Continuous On (00h)

*Low Power (01h)

11-18