The text of a manual · part 15 of 33
MiniScan MS XX04 Series Integration Guide, pages 131 to 140
Pages 131 to 140 of 310
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 131
Parameter Menus
Table 11-1. Default Table (Continued) Parameter
Parameter Number
Default
Page Number
Composite (MS 2204, MS 2204VHD and MS 3204 only) CC-C
F0h 55h
Disable
11-105
CC-AB
F0h 56h
Disable
11-106
TLC-39
F0h 73h
Disable
11-107
UPC Composite Mode
F0h 58h
Always Linked
11-108
Transmit Code ID Character
2Dh
None
11-109
Prefix/Suffix Values Prefix Suffix 1 Suffix 2
69h 68h 6Ah
NULL LF CR
Scan Data Transmission Format
EBh
Data as is
11-113
Baud Rate
9Ch
9600
11-115
Parity
9Eh
None
11-117
Check Parity
97h
Enable
11-119
Software Handshaking
9Fh
ACK/NAK
11-120
Host RTS Line State
9Ah
Low
11-121
Decode Data Packet Format
EEh
Unpacketed
11-122
Stop Bit Select
9Dh
1
11-123
Intercharacter Delay
6Eh
0
11-124
Data Options
11-111
Simple Serial Interface (SSI) Options
11-9
Page 132
MS XX04 Series Integration Guide
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
Host Serial Response Time-out
9Bh
2 sec
11-124
Host Character Time-out
EFh
200 msec
11-125
Decode Event
F0h 00h
Disable
11-127
Boot Up Event
F0h 02h
Disable
11-128
Parameter Event
F0h 03h
Disable
11-129
Parameter
Event Reporting
Macro PDF (MS 2204, MS 2204VHD, and MS 3204 only) Transmit Each Symbol in Codeword Format
Afh
Disable
11-130
Transmit Unknown Codewords
BAh
Disable
11-132
Escape Character
E9h
None
11-133
Delete Character Set ECIs
E6h
Enable
11-134
ECI Decoder
E8h
Enable
11-135
ECI (MS 2204, MS 2204VHD and MS 3204 only)
Transmit Macro PDF User-Selected Field (MS 2204, MS 2204VHD, and MS 3204 only) Transmit File Name
B0h
Disable
11-137
Transmit Block Count
B1h
Disable
11-138
Transmit Time Stamp
B2h
Disable
11-139
Transmit Sender
B3h
Disable
11-140
Transmit Addressee
B4h
Disable
11-141
Transmit Checksum
B6h
Disable
11-142
11-10
Page 133
Parameter Menus
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
Transmit File Size
B5h
Disable
11-143
Transmit Macro PDF Control Header
B7h
Disable
11-144
Last Block Marker
B9h
Disable
11-145
Parameter
11-11
Page 134
MS XX04 Series Integration Guide
Set Default Parameter Scan this bar code to return all parameters to the values listed in Table 11-1 on page 11-3.
Set All Defaults
11-12
Page 135
Parameter Menus
Scanning Options Beeper Volume Parameter # 8Ch To select a decode beep volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume
Medium Volume
*High Volume
11-13
Page 136
MS XX04 Series Integration Guide
Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the appropriate bar code.
Low Frequency (02h)
Medium Frequency (01h)
*High Frequency (00h)
11-14
Page 137
Parameter Menus
Beeper Frequency Adjustment Parameter # F0h 91H Note: This option is not supported by MS 904HS. This parameter adjusts the frequency of the high beeper tone from the nominal 2500 Hz to another frequency matching the resonances of the installation. It is programmable in 10 Hz increments from 1220 Hz to 3770 Hz. To increase the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 11-146 that correspond to the desired frequency adjustment divided by 10. For example, to set the frequency to 3000 Hz (an increase of 500 Hz), scan numeric bar codes 0, 5, 0, corresponding to 50, or (500/10). To decrease the frequency, scan the bar code below, then scan three numeric bar codes beginning on page 11-146 that correspond to the value (256 - desired adjustment/10). For example, to set the frequency to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes 2, 0, 6, corresponding to 206, or (256 - 500/10).
Beeper Frequency Adjustment
11-15
Page 138
MS XX04 Series Integration Guide
Laser On Time Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 11-146 that correspond to the desired on time. Times less than 1.0 second must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or to cancel an incorrect entry, scan the Cancel bar code on page 11-148.
Laser On Time
11-16
Page 139
Parameter Menus
Scan Angle Parameter # BFh Note: This option is supported by the MS 1204FZY and MS 804FZY only. This parameter sets the scan angle.
*Default Angle (06h)
Alternate Angle (05h)
11-17
Page 140
MS XX04 Series Integration Guide
Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In Low Power mode, the scanner enters into a low power consumption mode when possible, provided all WAKEUP signals are released. In Continuous On mode, power remains on after each decode attempt.
Continuous On (00h)
*Low Power (01h)
11-18