The text of a manual · part 14 of 33
MiniScan MS XX04 Series Integration Guide, pages 121 to 130
Pages 121 to 130 of 310: Chapter 10 Maintenance and Troubleshooting; Chapter 11 Parameter Menus
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 121
Chapter 10 Maintenance and Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.
Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the scan window with a damp cloth and, if necessary, a non-ammonia based detergent.
10-1
Page 122
MS XX04 Series Integration Guide
Troubleshooting Problem No red LED or nothing happens during a scan attempt.
Possible Cause
Possible Solutions
No power to the scanner.
Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.
Scanner cannot read the bar Interface/power cables are loose. Re-connect loose cables. code. Scanner is not programmed for Make sure the scanner is the correct bar code type. programmed to read the type of bar code to be scanned. Try scanning other bar code(s) and other bar code types. Incorrect communication parameters.
Set the correct communication parameters (baud rate, parity, stop bits, etc.)
Bar code symbol is unreadable.
Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type.
Inappropriately hot environment.
Remove the scanner from the hot environment, and allow it to cool down.
Laser activates, followed by Beeper is configured. a beep sequence.
Refer to Table 3-1 on page 3-9 for beeper indication descriptions.
Note: If after performing these checks the symbol still does not scan, contact the distributor or call the Symbol Support Center at the telephone number listed on page xiii.
10-2
Page 123
Chapter 11 Parameter Menus This chapter describes the programmable parameters, and provides bar codes for programming and hexadecimal equivalents for host download programming. Throughout the programming bar code menus, default values are indicated with asterisks (*).
*Low Power * Indicates Default
Feature/Option
(01h) Hex Value
11-1
Page 124
MS XX04 Series Integration Guide
Operational Parameters MiniScan scanners are shipped with the default settings shown in Table 11-1 on page 113. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. There are two ways to change the default values: •
Scan the appropriate bar codes in this chapter. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set All Defaults bar code on page 11-12.
•
Download data through the scanner’s serial port using Symbol’s Simple Serial Interface (SSI). Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method.
Default Table Table 11-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any option, scan the appropriate bar code(s).
11-2
Page 125
Parameter Menus
Table 11-1. Default Table Parameter
Parameter Number
Set Default Parameter
Default
Page Number
All Defaults
11-12
Scanning Options Beeper Volume
8Ch
High Volume
11-13
Beeper Tone
91h
High Frequency
11-14
F07 91h
2500 Hz
11-15
Laser On Time
88h
3.0 sec (MS 2204/ 2204VHD/3204: 5.0 sec)
11-16
Scan Angle (MS 1204FZY and MS 804FZY only)
BFh
Wide
11-17
Power Mode
80h
Low Power
11-18
Trigger Mode
8Ah
Level
11-19
Scanning Mode (MS 2204, MS 2204VHD, and MS 3204 only)
8Dh
Smart Raster
11-20
F0h 7Eh
Disabled
11-21
Raster Height (MS 2204, MS 2204VHD, and MS 3204-I000 only)
E4h
15
11-22
Raster Expansion Rate (MS 2204, MS 2204VHD, and MS 3204-I000 only)
E5h
11
11-22
Time-out Between Same Symbol
89h
0.6 sec (MS 804FZY/904HS: 1.0 sec)
11-23
Time-out Between Different Symbols
90h
0.0 sec
11-23
Beeper Frequency Adjustment (not supported by MS 904HS)
Aiming Mode
11-3
Page 126
MS XX04 Series Integration Guide
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
Beep After Good Decode
38h
Enable
11-24
Transmit “No Read” Message
5Eh
Disable
11-25
Parameter Scanning
ECh
Enable
11-26
Linear Code Type Security Level
4Eh
1 (MS 2204/2204VHD/ 3204: 2)
11-27
Bi-directional Redundancy
43h
Disable
11-29
UPC-A
01h
Enable
11-30
UPC-E
02h
Enable
11-30
UPC-E1
0Ch
Disable
11-32
EAN-8
04h
Enable
11-33
EAN-13
03h
Enable
11-34
Bookland EAN
53h
Disable
11-35
UPC/EAN Coupon Code
55h
Disable
11-36
Decode UPC/EAN Supplementals
10h
Ignore
11-37
Decode UPC/EAN Supplemental Redundancy
50h
20 (MS 804FZY/ MS 904HS: 7)
11-39
Transmit UPC-A Check Digit
28h
Enable
11-40
Transmit UPC-E Check Digit
29h
Enable
11-41
Transmit UPC-E1 Check Digit
2Ah
Enable
11-42
Parameter
UPC/EAN
11-4
Page 127
Parameter Menus
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
UPC-A Preamble
22h
System Character
11-43
UPC-E Preamble
23h
System Character
11-44
UPC-E1 Preamble
24h
System Character
11-45
Convert UPC-E to A
25h
Disable
11-46
Convert UPC-E1 to A
26h
Disable
11-47
EAN-8 Zero Extend
27h
Disable
11-48
UPC/EAN Security Level
4Dh
0
11-49
Linear UPC/EAN Decode
44h
Disable
11-51
UPC Half Block Stitching (MS 2204/ MS 2204VHD/MS 3204 only)
4Ah
Disable
11-52
Code 128
08h
Enable
11-53
UCC/EAN-128
0Eh
Enable
11-54
ISBT 128
54h
Disable (MS 1204FZY: Enable)
11-55
Code 128 Decode Performance (MS 2204/MS 2204VHD/ MS 3204 only)
48h
Enable
11-56
Code 128 Decode Performance Level (MS 2204/MS 2204VHD/ MS 3204 only)
49h
Level 3
11-57
Parameter
Code 128
11-5
Page 128
MS XX04 Series Integration Guide
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
Code 39
00h
Enable
11-58
Trioptic Code 39
0Dh
Disable
11-59
Convert Code 39 to Code 32
56h
Disable
11-60
Code 32 Prefix
E7h
Enable (MS 804FZY/ MS 904HS: Disable)
11-61
Set Length(s) for Code 39
12h 13h
Length within Range: MS 1204FZY/MS 804FZY: 02-55 MS 2204/2204VHD/ MS 3204: 01-55 MS 904HS: 04-37
11-62
Code 39 Check Digit Verification
30h
Disable
11-64
Transmit Code 39 Check Digit
2Bh
Disable
11-65
Code 39 Full ASCII Conversion
11h
Disable
11-66
Code 39 Decode Performance (MS 2204/MS 2204VHD/ MS 3204 only)
46h
Enable
11-67
Code 39 Decode Performance Level (MS 2204/MS 2204VHD/ MS 3204 only)
47h
Level 3
11-68
09h
Disable
11-69
1Ah 1Bh
Length within Range: 04-55
11-70
Parameter Code 39
Code 93 Code 93 Set Length(s) for Code 93
11-6
Page 129
Parameter Menus
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
0Ah
Disable
11-72
1Ch 1Dh
Length within Range: 04-55
11-73
Code 11 Check Digit Verification
34h
Disable
11-75
Transmit Code 11 Check Digits
2Fh
Disable
11-76
06h
Disable (MS 1204FZY: Enable)
11-77
16h 17h
1 Discrete Length: 14
11-78
I 2 of 5 Check Digit Verification
31h
Disable
11-80
Transmit I 2 of 5 Check Digit
2Ch
Disable
11-81
Convert I 2 of 5 to EAN 13
52h
Disable
11-82
Discrete 2 of 5
05h
Disable
11-83
Set Length(s) for D 2 of 5
14h 15h
1 Discrete Length: 12
11-84
Codabar
07h
Disable
11-86
Set Lengths for Codabar
18h 19h
Length within Range: 05-55
11-87
Parameter Code 11 Code 11 Set Length(s) for Code 11
Interleaved 2 of 5 Interleaved 2 of 5
Set Length(s) for I 2 of 5
Discrete 2 of 5
Codabar
11-7
Page 130
MS XX04 Series Integration Guide
Table 11-1. Default Table (Continued) Parameter Number
Default
Page Number
CLSI Editing
36h
Disable
11-89
NOTIS Editing
37h
Disable
11-90
MSI Plessey
0Bh
Disable
11-91
Set Length(s) for MSI Plessey
1Eh 1Fh
Length Within Range: 06 - 55 (MS 904HS: 05 - 55)
11-92
MSI Plessey Check Digits
32h
One
11-94
Transmit MSI Plessey Check Digit
2Eh
Disable
11-95
MSI Plessey Check Digit Algorithm
33h
Mod 10/Mod 10
11-96
Parameter
MSI Plessey
PDF417/MicroPDF417 (MS 2204, MS 2204VHD, and MS 3204 only) PDF417
0Fh
MS 220X: Enable MS 3204: Disable
11-97
MicroPDF417
E3h
Disable
11-98
MicroPDF Performance
F0h 65h
Standard
11-99
Code 128 Emulation
7Bh
Disable
11-100
RSS-14
F0h 52h
Disable
11-101
RSS-Limited
F0h 53h
Disable
11-102
RSS-Expanded
F0h 54h
Disable
11-103
Convert RSS to UPC/EAN (MS 1204FZY only)
F0h 8Dh
Disable
11-103
RSS (not supported by MS 904HS)
11-8