Page 121

Chapter 10 Maintenance and Troubleshooting Overview The chapter provides information on maintenance and troubleshooting.

Maintenance Cleaning the exit window is the only maintenance required. Do not allow any abrasive material to touch the window. Clean the scan window with a damp cloth and, if necessary, a non-ammonia based detergent.

10-1

Page 122

MS XX04 Series Integration Guide

Troubleshooting Problem No red LED or nothing happens during a scan attempt.

Possible Cause

Possible Solutions

No power to the scanner.

Check the system power. Confirm that the correct host interface cable is used. Connect the power supply. Re-connect loose cables.

Scanner cannot read the bar Interface/power cables are loose. Re-connect loose cables. code. Scanner is not programmed for Make sure the scanner is the correct bar code type. programmed to read the type of bar code to be scanned. Try scanning other bar code(s) and other bar code types. Incorrect communication parameters.

Set the correct communication parameters (baud rate, parity, stop bits, etc.)

Bar code symbol is unreadable.

Check the symbol to make sure it is not defaced. Try scanning similar symbols of the same code type.

Inappropriately hot environment.

Remove the scanner from the hot environment, and allow it to cool down.

Laser activates, followed by Beeper is configured. a beep sequence.

Refer to Table 3-1 on page 3-9 for beeper indication descriptions.

Note: If after performing these checks the symbol still does not scan, contact the distributor or call the Symbol Support Center at the telephone number listed on page xiii.

10-2

Page 123

Chapter 11 Parameter Menus This chapter describes the programmable parameters, and provides bar codes for programming and hexadecimal equivalents for host download programming. Throughout the programming bar code menus, default values are indicated with asterisks (*).

*Low Power * Indicates Default

Feature/Option

(01h) Hex Value

11-1

Page 124

MS XX04 Series Integration Guide

Operational Parameters MiniScan scanners are shipped with the default settings shown in Table 11-1 on page 113. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. There are two ways to change the default values: •

Scan the appropriate bar codes in this chapter. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set All Defaults bar code on page 11-12.

•

Download data through the scanner’s serial port using Symbol’s Simple Serial Interface (SSI). Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options are shown in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method.

Default Table Table 11-1 lists the defaults for all parameters, and the page number each parameter appears on. To change any option, scan the appropriate bar code(s).

11-2

Page 125

Parameter Menus

Table 11-1. Default Table Parameter

Parameter Number

Set Default Parameter

Default

Page Number

All Defaults

11-12

Scanning Options Beeper Volume

8Ch

High Volume

11-13

Beeper Tone

91h

High Frequency

11-14

F07 91h

2500 Hz

11-15

Laser On Time

88h

3.0 sec (MS 2204/ 2204VHD/3204: 5.0 sec)

11-16

Scan Angle (MS 1204FZY and MS 804FZY only)

BFh

Wide

11-17

Power Mode

80h

Low Power

11-18

Trigger Mode

8Ah

Level

11-19

Scanning Mode (MS 2204, MS 2204VHD, and MS 3204 only)

8Dh

Smart Raster

11-20

F0h 7Eh

Disabled

11-21

Raster Height (MS 2204, MS 2204VHD, and MS 3204-I000 only)

E4h

15

11-22

Raster Expansion Rate (MS 2204, MS 2204VHD, and MS 3204-I000 only)

E5h

11

11-22

Time-out Between Same Symbol

89h

0.6 sec (MS 804FZY/904HS: 1.0 sec)

11-23

Time-out Between Different Symbols

90h

0.0 sec

11-23

Beeper Frequency Adjustment (not supported by MS 904HS)

Aiming Mode

11-3

Page 126

MS XX04 Series Integration Guide

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

Beep After Good Decode

38h

Enable

11-24

Transmit “No Read” Message

5Eh

Disable

11-25

Parameter Scanning

ECh

Enable

11-26

Linear Code Type Security Level

4Eh

1 (MS 2204/2204VHD/ 3204: 2)

11-27

Bi-directional Redundancy

43h

Disable

11-29

UPC-A

01h

Enable

11-30

UPC-E

02h

Enable

11-30

UPC-E1

0Ch

Disable

11-32

EAN-8

04h

Enable

11-33

EAN-13

03h

Enable

11-34

Bookland EAN

53h

Disable

11-35

UPC/EAN Coupon Code

55h

Disable

11-36

Decode UPC/EAN Supplementals

10h

Ignore

11-37

Decode UPC/EAN Supplemental Redundancy

50h

20 (MS 804FZY/ MS 904HS: 7)

11-39

Transmit UPC-A Check Digit

28h

Enable

11-40

Transmit UPC-E Check Digit

29h

Enable

11-41

Transmit UPC-E1 Check Digit

2Ah

Enable

11-42

Parameter

UPC/EAN

11-4

Page 127

Parameter Menus

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

UPC-A Preamble

22h

System Character

11-43

UPC-E Preamble

23h

System Character

11-44

UPC-E1 Preamble

24h

System Character

11-45

Convert UPC-E to A

25h

Disable

11-46

Convert UPC-E1 to A

26h

Disable

11-47

EAN-8 Zero Extend

27h

Disable

11-48

UPC/EAN Security Level

4Dh

0

11-49

Linear UPC/EAN Decode

44h

Disable

11-51

UPC Half Block Stitching (MS 2204/ MS 2204VHD/MS 3204 only)

4Ah

Disable

11-52

Code 128

08h

Enable

11-53

UCC/EAN-128

0Eh

Enable

11-54

ISBT 128

54h

Disable (MS 1204FZY: Enable)

11-55

Code 128 Decode Performance (MS 2204/MS 2204VHD/ MS 3204 only)

48h

Enable

11-56

Code 128 Decode Performance Level (MS 2204/MS 2204VHD/ MS 3204 only)

49h

Level 3

11-57

Parameter

Code 128

11-5

Page 128

MS XX04 Series Integration Guide

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

Code 39

00h

Enable

11-58

Trioptic Code 39

0Dh

Disable

11-59

Convert Code 39 to Code 32

56h

Disable

11-60

Code 32 Prefix

E7h

Enable (MS 804FZY/ MS 904HS: Disable)

11-61

Set Length(s) for Code 39

12h 13h

Length within Range: MS 1204FZY/MS 804FZY: 02-55 MS 2204/2204VHD/ MS 3204: 01-55 MS 904HS: 04-37

11-62

Code 39 Check Digit Verification

30h

Disable

11-64

Transmit Code 39 Check Digit

2Bh

Disable

11-65

Code 39 Full ASCII Conversion

11h

Disable

11-66

Code 39 Decode Performance (MS 2204/MS 2204VHD/ MS 3204 only)

46h

Enable

11-67

Code 39 Decode Performance Level (MS 2204/MS 2204VHD/ MS 3204 only)

47h

Level 3

11-68

09h

Disable

11-69

1Ah 1Bh

Length within Range: 04-55

11-70

Parameter Code 39

Code 93 Code 93 Set Length(s) for Code 93

11-6

Page 129

Parameter Menus

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

0Ah

Disable

11-72

1Ch 1Dh

Length within Range: 04-55

11-73

Code 11 Check Digit Verification

34h

Disable

11-75

Transmit Code 11 Check Digits

2Fh

Disable

11-76

06h

Disable (MS 1204FZY: Enable)

11-77

16h 17h

1 Discrete Length: 14

11-78

I 2 of 5 Check Digit Verification

31h

Disable

11-80

Transmit I 2 of 5 Check Digit

2Ch

Disable

11-81

Convert I 2 of 5 to EAN 13

52h

Disable

11-82

Discrete 2 of 5

05h

Disable

11-83

Set Length(s) for D 2 of 5

14h 15h

1 Discrete Length: 12

11-84

Codabar

07h

Disable

11-86

Set Lengths for Codabar

18h 19h

Length within Range: 05-55

11-87

Parameter Code 11 Code 11 Set Length(s) for Code 11

Interleaved 2 of 5 Interleaved 2 of 5

Set Length(s) for I 2 of 5

Discrete 2 of 5

Codabar

11-7

Page 130

MS XX04 Series Integration Guide

Table 11-1. Default Table (Continued) Parameter Number

Default

Page Number

CLSI Editing

36h

Disable

11-89

NOTIS Editing

37h

Disable

11-90

MSI Plessey

0Bh

Disable

11-91

Set Length(s) for MSI Plessey

1Eh 1Fh

Length Within Range: 06 - 55 (MS 904HS: 05 - 55)

11-92

MSI Plessey Check Digits

32h

One

11-94

Transmit MSI Plessey Check Digit

2Eh

Disable

11-95

MSI Plessey Check Digit Algorithm

33h

Mod 10/Mod 10

11-96

Parameter

MSI Plessey

PDF417/MicroPDF417 (MS 2204, MS 2204VHD, and MS 3204 only) PDF417

0Fh

MS 220X: Enable MS 3204: Disable

11-97

MicroPDF417

E3h

Disable

11-98

MicroPDF Performance

F0h 65h

Standard

11-99

Code 128 Emulation

7Bh

Disable

11-100

RSS-14

F0h 52h

Disable

11-101

RSS-Limited

F0h 53h

Disable

11-102

RSS-Expanded

F0h 54h

Disable

11-103

Convert RSS to UPC/EAN (MS 1204FZY only)

F0h 8Dh

Disable

11-103

RSS (not supported by MS 904HS)

11-8