The text of a manual · part 12 of 33
MiniScan MS XX04 Series Integration Guide: Chapter 8 MS 804FZY Specifications
Pages 101 to 110 of 310, from MiniScan MS XX04 Series Integration Guide
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 101
Chapter 8 MS 804FZY Specifications Overview This chapter provides the technical specifications for the MS 804FZY scanner.
8-1
Page 102
MS XX04 Series Integration Guide
MS 804FZY Electrical Interface
Figure 8-1. MiniScan Connector Table 8-1 lists the pin functions of the MS 804FZY interface.
Table 8-1. MS 804FZY Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
4
Not used
5
Ground
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50 mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
8-2
O = Output
Power supply ground input and signal ground reference.
Page 103
MS 804FZY Specifications
MS 804FZY Mechanical Drawings
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 8-2. MS 804FZY Mechanical Drawing
8-3
Page 104
MS XX04 Series Integration Guide
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 8-3. MS 804FZY Mechanical Drawing
8-4
Page 105
MS 804FZY Specifications
MS 804FZY Technical Specifications Table 8-2. MS 804FZY Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Idle Current Standby Current Vcc Noise Level
5.0 VDC ±10% 150 mA ±30 mA typical 110 mA ±10 mA typical 20 mA ±5 mA typical 200 mV peak-to-peak max.
Laser Power
0.9 mW ±0.1 mW, λ = 650 nm nominal
Scan Rate
50 (±6) scans/sec (bidirectional)
Print Contrast
Minimum 25% absolute dark/light reflectance measured at 650 nm.
Scan Angle
Default (Wide): 46.5° Alternate (Narrow): 35°
Scan Pattern
Single scan line
Skew Tolerance
± 60° from normal (see Figure 8-4 on page 8-7)
Pitch Angle
± 65° from normal (see Figure 8-4 on page 8-7)
Roll
± 30° from vertical (see Figure 8-4 on page 8-7)
Decode Depth of Field
See Figure 8-5 on page 8-8
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
Multiple 30” drops
Vibration
Withstands a random vibration of 6.5 G’s RMS along each of the 3 mutually perpendicular axes for a period of 1 hr per axis, over a frequency range of 20 Hz to 2,000 Hz.
ESD
± 15kV air discharge ± 8kV indirect discharge
Operating Temperature
-4° to 104°F (-20° to 40°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
8-5
Page 106
MS XX04 Series Integration Guide
Table 8-2. MS 804FZY Technical Specifications @ 23°C (Continued) Item
Description
Humidity
95% (non-condensing)
Laser Class
CDRH Class II, IEC Class 2
Height
1.02 in. (2.59 cm) maximum
Width
1.93 in. (4.90 cm) maximum
Depth
2.31 in. (5.87 cm) maximum
Weight
1.67 oz. (47.34 g)
8-6
Page 107
MS 804FZY Specifications
Skew
Pitch
+ 60° from normal
Pitch Angle
+ 65° from normal
Skew Angle
20 mil Symbol
20 mil Symbo l
Scan Beam
10 in
10 in
. (2
. (2
54 m
54 m m)
m)
Scan Beam
Roll Roll Angle
+ 30° from normal mil 20 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
10 in . (2
54 m m)
Scan Beam
Figure 8-4. Skew, Pitch and Roll 8-7
Page 108
MS XX04 Series Integration Guide
MS 804FZY Decode Zone The decode zone for the MS 804FZY scanner is shown in Figure 8-5. The figures shown are typical values. Table 8-3 lists the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-12. Note: Typical performance at 73˚ F (23˚ C) on high quality symbols.
MS 804FZY
5 mil 1.6 1.2
0.7 0.8
4.9 7.5 mil cm
12
30.48
9
22.86
6
15.25
3
7.62
0
0
3
7.62
6
15.25
9
22.86
12
30.48
15
38.10
8.2
11.4 100% UPC
13.5
18.5 40 mil
28.7
* 55 mil
5 12.7
10 25.4
15 38.1
33.4
20 50.8
25 63.5
30 76.2
Depth of Field *Minimum distance determined by symbol length and scan angle
Figure 8-5. MS 804FZY Decode Zone
8-8
38.10
10 mil
20 mil in. 0 cm 0 in. 15
35 88.9
W i d t h o f F i e l d
Page 109
MS 804FZY Specifications
Table 8-3. MS 804FZY Decode Distances Symbol Density/ Symbol p/n / Bar Code Type/ W-N Ratio
Typical Working Ranges
Guaranteed Working Ranges
Bar Code Content/ Contrast1
Near
Far
Near
Far
5 mil 64-17453-01 Code 39; 2.5:1
ABCDEFGH 90% MRD
1.6 in. 4.06 cm
4.9 in. 12.45 cm
2.5 in. 6.35 cm
4.0 in. 10.16 cm
7.5 mil 64-17452-01 Code 39; 2.5:1
ABCDEF 90% MRD
1.2 in. 3.05 cm
8.2 in. 20.83 cm
2.0 in. 5.08 cm
6.5 in. 16.51 cm
10 mil Code 39; 1:2.5
ABCDE 90% MRD
0.7 in. 1.78 cm
11.4 in. 28.96 cm
1.25 in. 3.18 cm
8.7 in. 22.10 cm
13 mil 64-05303-01 100% UPC
12345678905 90% MRD
0.8 in. 2.03 cm
13.5 in. 34.29 cm
1.5 in. 3.81 cm
11.0 in. 27.94 cm
20 mil 60-01429-01 Code 39; 2.2:1
123 90% MRD
Note 2
18.5 in. 46.99 cm
Note 2
14.0 in. 35.56 cm
40 mil 64-17457-01 Code 39; 2.2:1
AB 90% MRD
Note 2
28.7 in. 72.90 cm
Note 2
21.0 in. 53.34 cm
55 mil 64-17458-01 Code 39; 2.2:1
CD 90% MRD
Note 2
33.4 in. 84.84 cm
Note 2
23.0 in. 58.42 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on lower densities (not specified) largely depend on the width of the bar code and the scan angle. 3. Working range specifications at ambient temperature (23°C), pitch=15°, roll=0°, skew=0°, photographic quality, ambient light<200 ft-c.
8-9
Page 110
MS XX04 Series Integration Guide
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-12 describes how to calculate the usable scan length. The scan angle is provided in Table 8-3.
8-10