The text of a manual · part 11 of 33
MiniScan MS XX04 Series Integration Guide: Chapter 7 MS 3204 Specifications
Pages 89 to 100 of 310, from MiniScan MS XX04 Series Integration Guide
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MS-1204, Symbol MS-2204 and Symbol MS-3204
Page 89
Chapter 7 MS 3204 Specifications Overview This chapter provides the technical specifications for the MS 3204 scanner.
7-1
Page 90
MS XX04 Series Integration Guide
MS 3204 Electrical Interface This section describes the pin functions of the MS 3204 scanner.
Figure 7-1. MS 3204 Connector
Table 7-1. MS 3204 Electrical Interface Pin No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output on the device communicating with the scanner.
4
Not used
5
Ground
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with the RTS line. Optionally used by another device to signal the scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction with the CTS line. Optionally used by the scanner to signal another device that data is available to send.
9
Beeper/ Download
I/O
During normal operation this signal functions as an external beeper drive line. This signal can sink 50mA of current to drive an external beeper, and is normally pulled up. This signal is also used to begin Flash Download operation when grounded externally during power up.
*I = Input
7-2
Power supply ground input and signal ground reference.
O = Output
Page 91
MS 3204 Specifications
MS 3204 Mechanical Drawings
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 7-2. MS 3204 Mechanical Drawing
7-3
Page 92
MS XX04 Series Integration Guide
Notes: Unless otherwise specified: • •
Dimensions are in inches, dimensions in [ ] are mm. User mounting tolerances are not included.
Figure 7-3. MS 3204 Mechanical Drawing
7-4
Page 93
MS 3204 Specifications
MS 3204 Technical Specifications Table 7-2. MS 3204 Technical Specifications @ 23°C Item
Description
Power Requirements Input Voltage Scanning Current Standby Current Vcc Noise Level
+5.0 VDC ± 10% 250 ± 30 mA typical 25 ± 5 mA typical 200 mV peak-to-peak max.
Laser Power
0.7 mW typical, 0.8 mW maximum, λ = 650 nm
Scan Rate
640 scans/second
Scan Frequency: Horizontal
320 Hz ± 5 Hz
Scan Frequency: Vertical
282 Hz ± 5 Hz
Frame Rate
24 frames/sec. 12 Hz ±1 Hz (vertical)
Print Contrast
Minimum 35% absolute dark/light reflectance differential (PDF); 35% absolute dark/light reflectance differential (1D)
Scan Angle
Horizontal: 34o ±1.5o Vertical: 34o ±1.5o
Scan Pattern
MS-3204-I000: Omnidirectional, semi-omnidirectional, smart raster, high density single scan line MS-3204-E000: Omnidirectional only
Start Time
0.065 sec. to 75% of steady state horizontal amplitude
Skew Tolerance
± 15o from normal (see Figure 7-4 on page 7-7)
Pitch Angle
± 30o from normal (see Figure 7-4 on page 7-7)
Roll
± 4o from vertical (see Figure 7-4 on page 7-7) (For scanning benchmark label, assuming 3:1 codeword aspect ratio). Note that this is dependent on the decoder.
Decode Depth of Field
See Figure 7-5 on page 7-8 and Figure 7-6 on page 7-10
Beam Deviation (offset from the nominal)
Horizontal: ±3.0o Vertical: ±3.0o Horizontal tilt: ± 2o
7-5
Page 94
MS XX04 Series Integration Guide
Table 7-2. MS 3204 Technical Specifications @ 23°C (Continued) Item
Description o
Additional Post Shock Beam Deviation (2000G Shock)
Horizontal: ±3.0 max Vertical: ±6.0o max
Ambient Light Immunity Sunlight Artificial Light
8,000 ft. candles (86,112 lux) 450 ft. candles (4,844 lux)
Drop
30 inch drop
Vibration
Unpowered scanner withstands a random vibration along each of the X, Y and Z axes for a period of one hour per axis, defined as follows: 20 to 80 Hz Ramp up to 0.04 G^2/Hz at the rate of 3dB/ octave. 80 to 350 Hz 0.04 G^2/Hz 350 to 2000 Hz Ramp down at the rate of 3 dB/octave.
ESD
± 20kV air discharge ± 8kV indirect discharge
Sealing
IP54
Operating Temperature
-86 °F to 122 °F (-30 °C to 50 °C)
Storage Temperature
-104 °F to 158 °F (-40 °C to 70 °C)
Humidity
5% to 95% non-condensing
Laser Class
CDRH Class II, IEC Class 2
Height
1.89 in. (4.80 cm)
Width
2.31 in. (5.87 cm)
Depth
3.50 in. (8.89 cm)
Weight
4.8 oz. (137 g)
7-6
Page 95
MS 3204 Specifications
Skew
Pitch
+ 15° from normal
Pitch Angle
+ 30° from normal
Skew Angle
20 mil Symbol
20 mil Symbo l
Scan Beam
7.0
7.0 in. ( in. (
177
177
.8 m
.8 m m)
m)
Scan Beam
Roll Roll Angle
+4° from normal mil 20 bol Sym
Note: Tolerances are reduced at extreme ends of the working range.
7.0 in. ( 177
.8 m m)
Scan Beam
Figure 7-4. Skew, Pitch and Roll 7-7
Page 96
MS XX04 Series Integration Guide
MS 3204 Decode Zones The decode zone is a function of various symbol characteristics including density, print contrast, wide to narrow ratio and edge acuity. The figures shown are typical values. Table 7-3 on page 7-9 and Table 7-4 on page 7-11 list the typical and guaranteed distances for selected bar code densities. The minimum element width (or “symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol. The maximum usable length of a symbol at any given range is shown below. To calculate this distance, see Calculating the Usable Scan Length Method on page 2-12.
Omnidirectional Decode Distances Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Vcc = 5V in.
cm
5
12.7
2.5 6.35
W i d t h
0 o f
.25
0
1.00 6 mil
.25 1.00
2.5 6.35 3.25
80% UPC
5
6.5 100% UPC
1.5
12.5
20 mil
1.75
12.5
Depth of Field In. cm
0 0
2.5 12.7
5 25.4
7.5 38.1
10 50.8
12.5 63.5
Depth of Field * Minimum distance determined by symbol length and scan angle.
Figure 7-5. MS 3204 Omnidirectional Decode Zone
7-8
12.7
F i e l d
Page 97
MS 3204 Specifications
Table 7-3. MS 3204 Omnidirectional Decode Distances Symbol Density/ Symbol p/n / Bar Code Type
Bar Code Content/ Contrast1
Typical Working Ranges3
Guaranteed Working Ranges3
Near
Far
Near
Far
6.0 mil 60-01755-01 Code 39
123 80% MRD
0.25 in. 0.64 cm
3.25 in. 8.3 cm
0.75 in. 1.9 cm
2.25 in. 5.7 cm
64-06629-01 80% UPC
0080015 80% MRD
1.0 in. 2.5 cm
6.5 in. 16.5 cm
1.5 in. 3.8 cm
4.5 in. 11.4 cm
13 mil 64-05303-01 100% UPC
012345678905 80% MRD
1.5 in. 3.8 cm
12.5 in. 31.2 cm
Note 2
9.5 in. 24.1 cm
20 mil 1D 60-02710-03 LC 35%
123 80% MRD
1.75 in. 4.4 cm
12.5 in. 31.8 cm
Note 2
10.0 in. 25.4 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 15°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C, Vcc = 5V. 4. Measured from the front of the scanner.
7-9
Page 98
MS XX04 Series Integration Guide
2D Slab/Raster Decode Distances (MS 3204-I000 Only) In.
Note: Typical performance at 68˚F (20˚C) on high quality symbols in normal room light. Vcc = 5V cm
11 27.9 10 25.4 7.5 15.2
6.6 mil PDF 417 5.25 1.0 3.5
0 0
0
0
2.5
5.1
5
10.1
10
25.4
15 mil PDF 417
11
27.9
14.0
55 mil 1D
5 12.7
5.1
9.5
1.0
In. cm
10.1
7.5 15.2
10 mil PDF 417
6.5
5 2.5
10 25.4
15 38.1
32.0
20 50.8
25 63.5
30 76.2
35 88.9
Depth of Field * Minimum distance determined by symbol length and scan angle.
Figure 7-6. MS 3204 2D Slab/Raster Decode Distance
7-10
W i d t h o f F i e l d
Page 99
MS 3204 Specifications
Table 7-4. MS 3204-I000 2D Slab/Raster Decode Distances Symbol Density/ Symbol p/n / Bar Code Type
Bar Code Content/ Contrast1
Typical Working Ranges3 Near
Far
Guaranteed Working Ranges3 Near
Far
6.6 mil 64-14035-01 2D
123 80% MRD
1.0 in. 2.54 cm
5.25 in. 13.34 cm
1.5 in. 3.8 cm
3.75 in. 9.5 cm
10 mil 64-14037-01 2D
ABCDEF 80% MRD
3.5 in. 8.89 cm
9.5 in. 24.13 cm
5.0 in. 12.7 cm
7.5 in. 9.5 cm
15 mil 64-14038-01 2D
012345678905 80% MRD
6.5 in. 16.51 cm
14.0 in. 35.6 cm
Note 2
11.0 in. 24.1 cm
55 mil 64-17458-01 1D
CD 80% MRD
1.0 in. 2.54 cm
32 in. 81.3 cm
Note 2
22.0 in. 55.9 cm
Notes: 1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm. 2. Near ranges on largely depend on the width of the bar code and the scan angle. 3. Working range specifications: Photographic quality symbols, pitch = 15°, skew = 0°, roll = 0°, ambient light < 150 ft. candles, and temperature = 23 °C, Vcc = 5V. 4. Measured from the front of the scanner.
Usable Scan Length The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow ratio, and edge acuity. Consider width of decode zone at any given distance when designing a system. Calculating the Usable Scan Length Method on page 2-12 describes how to calculate the usable scan length. The scan angle is provided in Table 7-2 on page 7-5.
7-11
Page 100
MS XX04 Series Integration Guide
7-12