For the Symbol MK-1200
Page 31
Chapter 2 Installation Introduction This chapter describes MK1200 installation, including:
• Unpacking • Installation • Mounting • Providing power • Communication interfaces • Installing accessories • Peripherals
• Connector pin-outs • Optional accessories.
Unpacking the MK1200 Remove the MK1200 from its packing and inspect it for damage. Keep the packing, it is the approved shipping container and should be used if the MK1200 needs to be returned for servicing.
Page 32
2-2
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Installation Overview To install the MK1200: 1.
Select the mounting method (see MK1200 Mounting on page 2-3): • Wall Mount • Pole Mount • Desk Mount.
2.
Select the method of supplying power (see Connecting the MK1200 on page 2-7): • Symbol AC power supply • Power-Over-Ethernet.
3.
Select the data communications method (see Connecting the MK1200 on page 2-7): • Wired Ethernet (10 Base-T cable) • Wireless Ethernet (11Mb RF) • Wired Printer (RS-232, serial cable).
4.
Select a printer (see Printers on page 2-10).
5.
Configure the MK1200 if necessary: • For configuration, see Chapter 4, Remote Device Manager, System Menu on page 3-5, or <Blue><Italic>Control Panel Configuration Parameters on page -20. • To access the Windows® CE Desktop, see Accessing the Windows® CE Desktop on page 7-7.
Page 33
Installation
2-3
MK1200 Mounting If desired, mount the MK1200 on a wall, pole, or counter top using the following optional mounting accessories: • Wall Mounts • Pole Mount Kit, see page 2-6. NOTE
The MSR increases the width of the MK1200 from 8.92 inches to 11.5 inches. The height and depth do not change.
(4X) 4 mm x .7 pitch threaded holes (M4 screw) per VESA flat panel monitor physical mounting interface standard
3.94
1.29
8.51
7.93 3.94
4.00
1.65
.68
1.81
VESA/keyhole mounting face
5.00 0.41
1.28
Keyhole slide-on mounts 0.19 dia. shank, 0.312 dia. head
10.74
0.68 Notes:
7.57 8.92
All dimensions provided in inches. The MK1200 is designed to be used with VESA flat panel monitor physical mounting interface standard mounting brackets or Symbol's keyhole slide-on mounting brackets. It can also be placed into a flush panel kiosk environment by setting it into an 8.0 x 8.63 opening.
Figure 2-1 Mounting Dimensions
1.4 3.51
Page 34
2-4
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
MK1200 Wall Mounting Options Wall mounting options include:
• Free wall-mounting template (shipped with the unit) • Wall Mount Kit (optional) • Recessing the MK1200 into a wall (see page 2-5) (optional).
Using the Wall Mount Kit 1.
Determine the MK1200 mounting location.
2.
Follow the instructions and use the template provided with the MK1200. Secure the Connector/Port Cover to the wall using four screws (not provided) appropriate for the wall material.
3.
Connect the cables to the MK1200 (see Figure 2-3 on page 2-5) and ensure the cables are routed and secured correctly (see Figure 2-4 on page 2-5). Cables incorrectly mounted or secured can become pinched when the MK1200 is attached to the Connector/Port Cover.
4.
To install the Connector/Port Cover, place the keyholes on the back housing over the shoulder head bolts protruding from the plate and slide the MK1200 to the left and down to secure in place. See Wall Mounting Kit on page 2-4 and Mounting Directions on page 2-5.
5.
Screw one 8-32 pan head screw (lock screw) into the Connector/Port Cover tab (located at the top left corner). Hand tighten the screw, or for additional security use a nylon locknut (not included) to prevent removal of the device.
6.
Proceed to Connecting the MK1200 on page 2-7.
Lock Screw Connector/Port Cover Tab
Shoulder Head Bolts (4)
Connector/Port Cover
Figure 2-2 Wall Mounting Kit
Page 35
Installation
2-5
Move to the left first
Move down second
Figure 2-3 Mounting Directions
Vertical Cable Run
Figure 2-4 Cable Routing
Recessed Wall Mounting To recess the MK1200: 1.
Cut an opening in the wall, 8.63" minimum height x 8.0" minimum width.
2.
Place the back housing into the opening, following the instructions in Using the Wall Mount Kit on page 2-4. See Figure 2-2 and Figure 2-3 on page 2-5. Symbol does not provide hardware to support this installation. NOTE
Recessed mounting may degrade wireless network performance.
Page 36
2-6
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Pole Mounting The Pole Mounting Kit accommodates poles up to 11.5 inches in diameter. To install the MK1200 using the Pole Mounting Kit: 1.
Wrap the pole mount straps around the pole and tighten.
2.
Secure the connector port cover to the pole mount bracket using the four shoulder screws.
3.
Connect the cables to the MK1200 (see Figure 2-3 on page 2-5) and ensure the cables are routed and secured correctly (see Figure 2-4 on page 2-5). Cables incorrectly mounted or secured can become pinched when the MK1200 is attached to the Connector/Port Cover.
4.
Position the MK1200 keyholes located on the back housing (see Figure 2-2 on page 2-4) over the shoulder head bolts and slide the MK1200 to the left and down to secure in place. See Wall Mounting Kit on page 2-4 and Mounting Directions on page 2-5.
5.
Screw one 8-32 pan head locking screw into the pole mount bracket bottom left tab. See Figure 2-5 on page 2-6. Hand tighten the locking screw, or for additional security use a nylon locknut (not included), to prevent removal of the device.
6.
Proceed to Connecting the MK1200 on page 2-7.
Pole Mount Bracket:
Locking Screw
Shoulder Screws (4)
Connector/Port Cover
Figure 2-5 Pole Mount Kit
Page 37
Installation
2-7
Connecting the MK1200 The MK1200 communication interfaces include both wired and wireless solutions:
• Wired Ethernet (10 Base-T cable) • Power via AC outlet (see below) • Power via Symbol’s BiasT Power-Over-Ethernet (see page 2-8)
• Wireless Ethernet (11Mb RF) • Wired RS-232 (serial cable) (see page 2-9). To configure the communications interfaces, see Chapter 4, Remote Device Manager. To access the Windows® CE Desktop, see Accessing the Windows® CE Desktop on page 7-7.
AC Power Supply The Symbol universal AC power supply has a positive center pin and the outer tab is ground. It is compatible with:
• 120V 60 Hz (North America) • 230V 50 Hz (International excluding Japan) • 100V 50/60 Hz (Japan).
Wired Ethernet Connection With a wired Ethernet connection, Ethernet-enabled MK1200 models are powered either using the MK1200’s Symbol AC power supply, or by Power-Over-Ethernet through the Ethernet cable.
Wired Ethernet: Power via AC Outlet The MK1200 communicates to the host via a 10 Base-T Ethernet cable and receives power via a Symbol AC power supply. 1.
Insert the power supply’s barrel connector into the MK1200’s power port. See Figure 1-3 on page 1-5.
2.
Route the power cable.
3.
Plug the Symbol AC power supply into a wall outlet.
4.
Connect the Ethernet cable to the LAN port on the MK1200. See Figure 1-3 on page 1-5. Ensure the Ethernet cable is terminated according to Table 2-2 on page 2-11.
5.
Plug the other end of the Ethernet cable into the host system’s LAN port.
Page 38
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Wired Ethernet: Power via POE The POE installation option allows the MK1200 to communicate and receive power on the same 10 Base-T Ethernet cable. See Figure 1-6 on page 1-10 and Figure 1-7 on page 1-10. CAUTION
DO NOT use POE in conjunction with an external power supply connected to the power port on the MK1200. Using two power sources can damage the MK1200 and/or the network.
1.
Connect the Ethernet cable to the MK1200 Ethernet / Bias-T port. See Figure 1-3 on page 1-5.
2.
Ensure the Ethernet cable is terminated according to Table 2-2 on page 2-11.
3.
Plug the other end of the Ethernet cable into the Bias-T (POE) module.
4.
Connect a patch cable from the Bias-T module to the host system’s Ethernet port.
5.
Connect the DC power supply to the Bias-T module. Customer Switch / Hub P/N 50-14001-006R DC Power Supply
AP-PSBIAS-TR
DC Power Supply
AP-PSBIAS-TR
Category 5 Patch Cable
P/N 50-14001-006R
100m Category 5 Specification Limit
2-8
Customer Patch Panel Category 5 Category 5
MK1200 MicroKiosk Figure 2-6 MK1200 Power-Over-Ethernet, Network Connectivity