MDM 3006 Modem Module Quick Reference, pages 26 to 32

Pages 26 to 32 of 32: Technical Specifications; Regulatory Information

The original document is the PDF (266 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol MDM-3006

Page 26

M D M M o d e m

3 0 0 6 M o d u l e

Technical Specifications Item

Description

Asynchronous character format

Up to 10 bits, including data, start, stop, and parity bits

Asynchronous data rates

Transmission rate fallback through 300 bps

Chipset

Conexant SCM

Compatible public switched network jacks

RJ11

Dialing capability

Tone and rotary pulse

Line requirements

Public switched telephone network (PSTN) including international connections

Operating environment

Altitude: up to 20,000 ft. Humidity: 10% to 90% non-condensing

Operating temperature

Operating: 0o to 50oC Storage: -20o to 65oC

Operating modes

Asynchronous, full duplex, automatic and manual call originate

Performance

Line speed up to 56,000 bps Terminal to modem speed (DTE speed) up to 230,400 bps, depending on terminal - 57,600 bps recommended V.42bis data compression V.42 LAPM error correction

Current consumption (typical)

160 mA connected state 155 mA disconnected state

Ringer equivalence

0.1B

Standards & protocols

Bell 103, Bell 212A, Hayes AT command set, ITU Versions: V.17, V.21, V.22A, V.22b, V.22bis, V.23, V.25, V.27ter, V.29, V.32, V.32bis, V.34, V.42bis, V.90

24

Page 27

Q u i c k

R e f e r e n c e

Regulatory Information All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void the user's authority to operate the equipment.

Power Supply Note:

Use only a Symbol-approved power supply (50-14000-107) output rated 9Vdc and minimum 2A. The power supply is certified to EN60950 with SELV outputs.

Hinweis: Benutzen Sie nur eine Symbol Technologies genehmigt Stromversorgung (50-14000-107) in den Ausgabe: 9Vdc und minimum 2A. Die Stromversorgung ist bescheinigt nach EN60950 mit SELV Ausgaben

Radio Frequency Interference Requirements Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help.

Radio Frequency Interference Requirements - Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

25

Page 28

M D M M o d e m

3 0 0 6 M o d u l e

Telecom Approval Warnings and Notices This product contains Symbol Modem Type MCDB

Connecting to the telephone network A compliant telephone lead is required with RJ11 plug (line is on middle pair) for connection to modem, terminated with an appropriate and correctly wired local telecom connector compatible with the telephone network. Such a cable may be sourced from your local supplier. Alternatively compliant RJ11 plug to RJ11 plug cables may be used with a range of adapters for places such as Europe. Caution:

To reduce risk of fire, use only No. 26 AWG or larger telecommunication line cord.

User and Service Access - No user service is intended and no part of the modem, other than the line connection plug, is accessible to users.

United States Where this device contains a Symbol Technologies, Inc. internal modem, this equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. A Supplier's Declaration of Conformity for the modem type may be obtained from http://www2.symbol.com/doc/ On the exterior of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. This equipment must be connected to the telephone network or premises wiring using a compatible modular jack (RJ11C) compliant with the applicable FCC Part 68 rules and requirements adopted by ACTA. A compliant telephone cord and modular plug must be used. This equipment must not be used on party lines.

26

Page 29

Q u i c k

R e f e r e n c e

If your premises has specially wired alarm equipment connected to the telephone line, ensure the installation of this modem does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. Should you experience trouble with this equipment, please contact your facility's Technical or Systems Support first who will contact your nearest Symbol Customer Service Centre. If necessary, the Symbol Support Centre may be contacted at: 1-800653-5350 If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. If the modem causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the modem. If this happens the telephone company will provide advance notice so you may make any necessary modifications to maintain uninterrupted service.

Fax The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device, including fax machines, to send any message unless it clearly contains a margin at the top or bottom of each transmitted page or on the first page of the transmission, the date and time it is sent and an identification of the business or other entity, or other individual sending the message and the telephone number of the sending machine or such business, other entity, or individual. (The telephone number provided may not be a 900 number or any other number for which charges exceed local or long-distance transmission charges.) In order to program this information into your fax/ modem, you should consult documentation supplied with the necessary fax driver application software being used with the host terminal.

Canada Where this equipment contains a modem supplied by Symbol Technologies, Inc., the product will be marked with IC: followed by the approval number. The Term "IC:" before the certification number only signifies that the Industry Canada technical specifications were met. Industry Canada does not guarantee the equipment will operate to the user's satisfaction.

27

Page 30

M D M M o d e m

3 0 0 6 M o d u l e

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution:

User should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.

The European Economic Area (EEA) Statement of Compliance for Modems Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/ The modem is designed to interwork with the following Public Switched Telephone Networks: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Liechtenstein, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom.

28

Page 31

Q u i c k

R e f e r e n c e

Warranty (A) Seller's hardware Products are warranted against defects in workmanship and materials for a period of ninety (90) days from the date of shipment, provided the Product remains unmodified and is operated under normal and proper conditions. Warranty provisions and durations on software, integrated installed systems, Product modified or designed to meet specific customer specifications ("Custom Products"), remanufactured products, and reconditioned or upgraded products, shall be as provided in the applicable Product specification in effect at the time of purchase or in the accompanying software license. (B) Products may be serviced or manufactured with parts, components, or subassemblies that originate from returned products and that have been tested as meeting applicable specifications for equivalent new material and Products. The sole obligation of Seller for defective hardware Products is limited to repair or replacement (at Seller's option) on a "return to service depot" basis with prior Seller authorization. Shipment to and from Seller will be at Seller's expense, unless no defect is found. No charge will be made to Buyer for replacement parts for warranty repairs. Seller is not responsible for any damage to or loss of any software programs, data or removable data storage media, or the restoration or reinstallation of any software programs or data other than the software, if any, installed by Seller during manufacture of the Product. The aforementioned provisions do not extend the original warranty period of any Product that had either been repaired or replaced by Seller. (C) The above warranty provisions shall not apply to any Product (i) which has been repaired, tampered with, altered or modified, except by Seller's authorized service personnel; (ii) in which the defects or damage to the Product result from normal wear and tear, misuse, negligence, improper storage, water or other liquids, battery leakage or failure to perform operator handling and scheduled maintenance instructions supplied by Seller; (iii) which has been subjected to unusual physical or electrical stress, abuse, or accident, or forces or exposure beyond normal use within the specified operational and environmental parameters set forth in the applicable Product specification; nor shall the above warranty provisions apply to any expendable or consumable items, such as batteries, supplied with the Product. EXCEPT FOR THE WARRANTY OF TITLE AND THE EXPRESS WARRANTIES STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HERUNDER INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABLILTY AND FITNESS FOR A PARTICULAR USE. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD. SOME STATES OR COUNTRIES DO NOT ALLOW A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS. IN SUCH STATES OR COUNTIRES, FOR SUCH PRODUCTS, SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY. The stated express warranties are in lieu of all obligations or liabilities on the part of Seller for damages, including but not limited to, special, indirect or consequential damages arising out of or in connection with the use or performance of the Product or service. Seller's liability for damages to Buyer or others resulting from the use of any Product or service furnished hereunder shall in no way exceed the purchase price of said Product or the fair market value of said service, except in instances of injury to persons or property.

29

Page 32

Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: United States1

1-800-653-5350 1-631-738-2400

Canada

905-629-7226

United Kingdom

0800 328 2424

Asia/Pacific

337-6588

Australia

1-800-672-906

Austria/Österreich

1-505-5794-0

Denmark/Danmark

7020-1718

Finland/Suomi

9 5407 580

France

01-40-96-52-21

Germany/Deutchland

6074-49020

Italy/Italia

2-484441

Mexico/México

5-520-1835

Netherlands/Nederland

315-271700

Norway/Norge

South Africa

11-8095311

Spain/España

Sweden/Sverige

84452900

Latin America Sales Support

1-800-347-0178 Inside US +1-561-483-1275 Outside US

Europe/Mid-East Distributor Operations

Contact local distributor or call +44 118 945 7360

+47 2232 4375 91 324 40 00 Inside Spain +34 91 324 40 00 Outside Spain

1Customer support is available 24 hours a day, 7 days a week.

For the latest version of this guide go to: http://www.symbol.com/manuals.

72-55338-02 Revision A, July 2002 Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300