The text of a manual · part 5 of 6
MDM 3006 Modem Module Quick Reference, pages 21 to 25
Pages 21 to 25 of 32: Modem Country Setup; Troubleshooting
The original document is the PDF (266 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MDM-3006
Page 21
Q u i c k
R e f e r e n c e
Modem Country Setup The modem defaults to operation with US telephone networks (country code: B5). To operate the modem with other country telephone networks, you must set the appropriate country code by entering the Country of Installation command. The modem will adjust it’s operating parameters to comply with the telephone network in the country specified. Syntax +GCI=<country_code> Enter this command in the Init String: text box for Palm OS, described in step 12 on page 6 or in the Extra dial-string modem commands: text box of the Modem Settings screen, described in step 20 on page 11 and step 7 on page 15 Supported Countries Country
Code
Country
Austria
FD or 0A
Greece
Belgium
FD or 0F
Iceland
Brazil
16
Ireland
Canada
20
Italy
Denmark
FD or 31
Finland
Code 46
Country
Code
Norway
FD or 82
FD
Portugal
8B
FD or 57
Spain
FD or A0
FD or 59
Sweden
FD or A5
Liechtenstein
FD
Switzerland
FD or A6
FD or 3C
Luxembourg
FD
TBR-21 (Europe)
FD
France
FD or 3D
Mexico
73
United Kingdom
FD or B4
Germany
FD or 42
Netherlands
FD or 7B
United States
B5 (Default)
Note: It is highly recommended that you use FD where possible. If you have trouble connecting, use the alternate code where provided.
19
Page 22
M D M M o d e m
3 0 0 6 M o d u l e
Troubleshooting Symptom
Possible Cause
Action
Terminal not communicating through the MDM 3006.
The modem cable is not fully connected.
Ensure the modem cable is connected securely to both the MDM 3006 and to the telephone jack.
MDM 3006 is not securely attached to the bottom of the terminal.
Remove and re-attach the MDM3006, ensure it is firmly seated on the bottom of the terminal.
Communications software is not installed or configured properly.
Perform setup as described in Configuring for Palm OS on page 4, Configuring for Pocket PC 2000 on page 8, or Configuring for Pocket PC 2002 on page 13.
Problems in the telephone lines that prevent communication.
Connect a conventional telephone and dial the remote modem to verify the telephone lines are functioning propoerly. You should hear the remote modem answer the call and emit answering tones. If not, contact the remote System Administrator.
Terminal’s battery is low or discharged. Power to the modem is shut off if the battery is low.
Ensure you have a charged battery. Use an external DC power adaptor to recharge the battery.
20
Page 23
Q u i c k
Symptom
R e f e r e n c e
Possible Cause
Action
Terminal battery The power cable is not is not charging fully connected. through the Power ConnecTerminal and modem tor. were unplugged from AC power too soon.
Ensure the power cable is connected securely to both the MDM 3006 and to AC power. Plug the terminal and modem back into the AC power source. If a terminal battery pack is fully depleted, it can take 2 hours to fully recharge (if the terminal is suspended) and longer if the terminal is operating.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
MDM 3006 device is not securely attached to the bottom of the terminal.
Remove and re-attach the MDM 3006, ensure it is firmly attached on the bottom of the terminal. Verify that the battery is charging by tapping Start Settings - System - Power.
21
Page 24
M D M M o d e m
Symptom ActiveSync fails.
3 0 0 6 M o d u l e
Possible Cause
Action
A partnership was not established with the host computer.
Establish a partnership with the host computer. See Host Computer Setup on page 4, page 8, and page 13.
Host computer is not selected in the ActiveSync dialogue on the terminal.
Select host computer in the ActiveSync dialogue. See How to Dial in on page 8, page 11, and page 15.
Modem RAS connection not allowed by host computer.
Select RAS connection at the host computer in the File - Connection Settings dialog box. Refer to the ReadMe files located in the Microsoft ActiveSync folder on your host computer.
Terminal or MDM 3006 was disconnected from the telephone line while the ActiveSync was in progress.
Disconnect the modem cable for 30 seconds to hang up the local telephone connection. Close any open windows on the terminal and any modem connections.
Synchronization did occur, however the session is configured to close immediately after synchronization is complete.
Pocket PC 2000: Verify the setting of the Disconnect when completed check box on the ActiveSync dialog when connected. Pocket PC 2002: Verify the setting of the When manually synchronizing disconnect when complete check box by tapping Start - ActiveSync - Tools - Options - Schedule tab.
22
Page 25
Q u i c k
R e f e r e n c e
Symptom
Possible Cause
Action
Dial-out fails
Location setting is incorrect.
Verify Dialing Locations. Verify Dialing Patterns are correct for your current location. For example, enter ‘G’ in the ‘For local calls, dial:’ field to dial directly, or ‘9,G’ if your telephone system requires ‘9’ to be dialed first to access an outside line.
Incorrect server phone number.
Verify the phone number you are connecting to from the Connecting dialog boxes.
For Pocket PC 20002 ‘Trouble Connecting: There is no answer at the number dialed. Verify the phone...’ error message appears
Modem may be required to be powered prior to opening port for dial-out. Tap Start - Settings - System - Symbol Settings - Settings - External5VoltPower and select ActiveOn.
Warm reset your terminal as described For Pocket PC 2002 the Connection Manag- in the Product Reference Guide for your er routes are incorrect. terminal. Confirm the connection settings. See How to Dial In on page 15. Terminal has successfully connected through modem, but no data is being transmitted over the connection.
Data is being transferred over S24 radio link.
Temporarily disable the radio link to force data transmission to use modem connection. Tap the wireless LAN icon from the systray on the Today screen. Tap the Mode/General tab. Enter an invalid value in the ESSID: text box. Power cycle the terminal. Verify that your radio link has been disabled (the wireless LAN icon has a red box with a ! on it). Once you have completed your data transmission, re-enable your radio link.
23