Page 495
Accessories
6. If necessary, enter the user name, password and domain.
Figure 12-43. My Connection Window - User Information Settings 7. Tap Advanced... to edit the Extra dial-string modem commands: text box to set country parameters to operate the modem with other country telephone networks.
Figure 12-44. Advanced Window - Extra Dial-String Modem Commands The modem defaults to operation with US telephone networks (country code: B5). To operate the modem with other country telephone networks, a country code must be entered. The modem adjusts its operating parameters to comply with the telephone network in the country specified. See Modem Country Setup on page 12-53 for the appropriate syntax and a list of country codes. 8. Tap ok to exit the Advanced window. 9. Tap Finish.
12-51
Page 496
12-52
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRG
Connecting the Modem To start the connection: 1. Tap Start - Settings - Connections tab - Connections. 2. In the Connections window, tap Manage existing connections.
Figure 12-45. My Connections Window 3. Tap and hold the connection name, then select Connect from the menu that appears. The modem attempts to connect.
Figure 12-46. Creating a Connection
Page 497
Accessories
Modem Country Setup Edit the Extra dial-string modem commands: text box in the mobile computer to set country parameters. The syntax used is: +GCI=<country_code>.
Supported Countries Table 12-6. Supported Countries Country
Code
Country
Code
Country
Code
Australia
09
Greece
FD or 46
Norway
FD or 82
Austria
FD or 0A
Iceland
FD
Portugal
FD or 8B
Belgium
FD or 0F
Ireland
FD or 57
Spain
FD or A0
Brazil
16
Italy
FD or 59
Sweden
FD or A5
Canada
20
Liechtenstein
FD
Switzerland
FD or A6
Denmark
FD or 31
Luxembourg
FD
TBR-21 (Europe)
FD
Finland
FD or 3C
Mexico
73
United Kingdom
FD or B4
France
FD or 3D
Netherlands
FD or 7B
United States
B5 (Default)
Germany
FD or 42
New Zealand
7E
Note: Use FD where possible. If connection problems occur, use the alternate code where provided.
12-53
Page 498
12-54
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRG
AT Commands The AT Command Set allows you to custom-configure the modem. Only experienced users having difficulty with default settings should use this feature.
Changing the Initialization String To enter AT commands: 1. Tap Start - Settings - Connections tab - Connections icon. 2. If creating a new connection, select Add a new modem connection in the Connections window. Then follow steps 1 through 6 in Configuring the Mobile Computer for the Modem on page 12-49 and proceed to Step 6.
Figure 12-47. Connections Window 3. If entering AT commands for an existing connection, select Manage existing connections in the Connections window.
Page 499
Accessories
4. On the Modem tab, select the radio button of the item to edit and tap Edit... .
Figure 12-48. New Connection Window 5. Tap Next until the User Information Settings window appears. 6. Tap Advanced... .
Figure 12-49. My Connection Window - User Information Settings
12-55
Page 500
12-56
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRG
7. Enter AT commands in the Extra dial-string modem commands: text box. See Basic AT Command Syntax on page 12-56.
Figure 12-50. Advanced Window - Extra Dial-String Modem Commands 8. Tap ok to exit the Advanced window. 9. Tap Finish.
Basic AT Command Syntax A command line is made up of three elements: • •
•
Prefix - consists of the characters “AT” or “at” or, to repeat the execution of the previous command line, “A/” or “a/”. Body - made up of individual commands described later. Space characters (IA5 2/0) are ignored and may be used for formatting purposes, unless they are embedded in numeric or string constants. The termination character may not appear in the body. The modem can accept at least 40 characters in the body. Termination character - may be selected by a user option (parameter S3). The default is CR.
Page 501
Accessories
The format of Basic Syntax commands, except for the D and S commands, is as follows: <command>[<number>] where: •
<command> is either a single character, or the “&” character followed by a single character per V.250; or the “%” character followed by a single character, the “*” character followed by a single character, or the “^” character followed by a single character. • <number> is a string of one or more characters from “0” through “9” representing a decimal integer value. Commands expecting a <number> are noted in the description of the command. If <number> is missing from such a command (<command> is immediately followed by another <command> or the termination character), the value “0” is assumed. If a command does not expect a <number> and a number is present, an error occurs. All leading “0”s in <number> are ignored by the modem. Additional commands may follow a command (and associated parameter, if any) on the same command line with a separation character. The actions of some commands cause the rest of the command line to be ignored. S-Parameters
Commands that begin with the letter “S” are known as “S-parameters”. The number following the “S” indicates the “parameter number” referenced. If the number is not recognized as a valid parameter number, an ERROR result code issues. Immediately following this number, either a “?” or “=” character must appear. “?” is used to read the current value of the indicated S-parameter; “=” sets the S-parameter to a new value. S<parameter_number>? S<parameter_number>=[<value>] If the “=” is used, the new value to be stored in the S-parameter is specified in decimal following the “=”. If no value is given (i.e., the end of the command line occurs or the next command follows immediately), the S-parameter specified may be set to 0, or an ERROR result code issues and the stored value remains. The ranges of acceptable values are given in the description of each Sparameter. If the “?” is used, the modem transmits a single line of information text to the DTE. The text portion of this information text consists of exactly three characters, giving the value of the S-parameter in decimal, with leading zeroes included.
12-57
Page 502
12-58
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRG
Commands The tables that follow summarize the AT commands, result codes, and S-Registers for the MDM 3000. <string> represents a letter, number, or symbol to be entered. <value> represents a number to be entered. Possible values are listed below the command.
Table 12-7. AT Command Table Command D
Description
Country Specific
Dial “D<string>” 0-9
DTMF digits 0-9
*
The ‘star’ digit (tone dialing only)
#
The ‘gate’ digit (tone dialing only)
A-D
DTMF digits A,B,C,D
L
Re-dial last number
P
Pulse dialing
T
Tone dialing
W
Wait for dial tone. (Modem waits for dial tone before dialing digits following “W”.)
@
Wait for silence. (Modem waits for at least 5 seconds of silence in the call progress frequency band before continuing with next dial string parameter.)
&
Wait for credit card dialing tone before continuing with the dial string.
‘
Dial pause. (Modem pauses for a time specified by S8 before dialing the digits following “,”)
;
Return to command state. (Modem goes off hook and allows entering additional AT commands. Use “H” to go back to on hook.)
() - <space>
Ignored. (Might be used to format the dial string.)
A
Off-hook and attempt to answer a call
H
Disconnect – Hang UP
O
Return to On-Line Data Mode. O <value> 0
Enters on-line data mode without a retrain.
1
Enters on-line data mode with a retrain.
X
X
Page 503
Accessories
Table 12-7. AT Command Table (Continued) Command
Description
L
Speaker volume (Not used)
M
Speaker control. M <value>
&G
0
Always off.
1
On during call establishment. Off when receiving carrier. (default)
2
Always on.
3
Off when receiving carrier and during dialing. On during answering.
Guard tone. &G<value> 0
Disables guard tone. (default)
1
Disables guard tone.
2
Select 1800 Hz guard tone.
&V1
Displays last connection statistics
+MS
Modulation Selection. +MS=<carrier>
%E
B103
Bell 103 (300)
B212
Bell 212 (1200 Rx/75 or 75Rx/1200 Tx)
V21
300
V22
1200
V22B
2400 or 1200
V23C
1200
V32
9600 or 4800
V32B
14400, 12000, 9600, 7200 or 4800
V34
33600, 31200, 28800, 26400, 2400, 21600, 19200, 16800, 14400, 12000, 9600, 7200, 4800 or 2400
Enable/Disable Line Quality Monitor and Auto-Retrain or Fall back/Fall forward. %E<value> 0
Disable line quality monitor and auto re-train.
1
Enable line quality monitor and auto re-train.
2
Enable line quality monitor and fallback/fall forward. (default).
Country Specific
X
X
12-59
Page 504
12-60
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRG
Table 12-7. AT Command Table (Continued) Command B
&L
Country Specific
Description CCITT or Bell. B<value> 0
Select CCITT operation at 300 or 1200 bauds.
1
Selects Bell operation at 300 or 1200 bauds.
Leased Line Operation. &L<value> 0
Requests dial-up operation. Dial-up operation continues.
Table 12-8. S-Register Settings Default Reg
Function
Range
De-fault
Saved
Units
S0
Rings to Auto Answer
0-255
0
* rings
S1
Ring Counter
0-255
0
* rings
S2
Escape Character
0-255
43
ASCII
S3
Carriage Return Character
0-127
13
ASCII
S4
Line Feed Character
0-127
10
ASCII
S5
Backspace Character
0-255
8
ASCII
S6
Wait Time before Blind Dialing or Dial Tone
2-255
2
*
S
S7
Wait Time for Carrier, Silence or Dial Tone
1-255
50
*
S
S8
Pause Time for Dial Delay Modifier
0-255
2
*
S
S9
Carrier Detect Response Time
1-255
6
*
0.1 S
S10
Lost Carrier to Hangup Delay
1-255
14
*
0.1 S
S11
DTMF Tone Duration
50-255
95
* mS
S12
Escape Prompt Delay (EPD)
0-255
50
*
.02 S
* Register value may be stored in on of two user ** Country-dependent