Page 161

Parameter Menus

Transmit Checksum Transmit Checksum activates transmission of the checksum field. The field character tag is \923\006. For example, the field may be: \923\00663823.

Enable Checksum Transmit

Disable Checksum Transmit

Transmit File Size Transmit File Size activates transmission of the file size field. The field character tag is \923\005. For example, the field may be: \923\005179234.

Enable File Size Transmit

Disable File Size Transmit

3-127

Page 162

CycloneTM M2000 Series Product Reference Guide

Transmit Macro PDF Control Header Transmit Macro PDF Control Header activates transmission of the control header, which contains the segment index and the file ID. For example, the field may be: \92800000\725\120\343. The five digits after the \928 are the segment index (or block index), and \725\120\343 is the file ID.

Enable Macro PDF Control Header Transmit

Disable Macro PDF Control Header Transmit

Last Blocker Marker Enable / Disable Last Block Marker enables marking the last block in the set by the codeword \922.

Enable Last Block Marker

Disable Last Block Marker

3-128

Page 163

Parameter Menus

Flush Macro Buffer This flushes the buffer of all decoded Macro PDF data stored to that point, transmits it to the host device, and aborts from Macro PDF mode.

Flush Macro PDF Buffer

Abort Macro PDF Entry This clears all currently-stored Macro PDF data in the buffer without transmission and aborts from Macro PDF mode.

Abort Macro PDF Entry

3-129

Page 164

CycloneTM M2000 Series Product Reference Guide

Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).

0

1

2

3

3-130

Page 165

Parameter Menus

Numeric Bar Codes (continued)

4

5

6

7

3-131

Page 166

CycloneTM M2000 Series Product Reference Guide

Numeric Bar Codes (continued)

8

9

Cancel If you make an error, or wish to change your selection, scan the bar code below.

Cancel

3-132

Page 167

Chapter 4 Advanced Data Formatting (ADF) Introduction Advanced Data Formatting (ADF) is a means of customizing, or editing, the data scanned by the scanner before transmitting the data to your host device. Scanned data can be edited to suit your particular requirements. ADF is implemented by scanning a related series of bar codes to create rules to apply to the scanned data. These bar codes appear later in this chapter.

Rules: Criteria Linked to Actions In ADF, data is customized through rules. These rules perform specific actions when the data meets certain criteria. One rule may consist of single or multiple actions applied to single or multiple criteria. For instance, a data formatting rule could be the following: Criteria:

When scan data is Code 39, length 12, and data at the start position is the string “129”,

Actions:

pad all sends with zeros to length 8, send all data up to X, send a space.

In this example, if a Code 39 bar code of 1299X1559828 is scanned, the following is transmitted: 00001299<space>. If a Code 39 bar code of 1299X15598 is scanned, this rule is ignored because the length (10 characters) does not pass the criteria. The rule specifies the editing conditions and requirements before data transmission occurs. 4-1

Page 168

CycloneTM M2000 Series Product Reference Guide

Using ADF Bar Codes When you program a rule, make sure the rule is logically correct. Plan ahead before you start scanning. To program each data formatting rule: 1. Start the Rule. Scan the Begin New Rule bar code on page 4-11. 2. Criteria. Scan the bar codes for all pertinent criteria. Criteria can include code type (e.g., Code 128), code length, or data that contains a specific character string (e.g., the digits “129”). These options are described in Criteria on page 4-14. 3. Actions. Scan all actions related to, or affecting, these criteria. The actions of a rule specify how to format the data for transmission. These options are described in Actions on page 4-25. 4. Save the Rule. Scan the Save Rule bar code on page 4-11. This places the rule in the “top” position in the rule buffer. If you make errors during this process, some special-purpose bar codes may be useful: Erase Criteria and Start Again, Erase Actions and Start Again, Erase Previously Saved Rule, and Erase All Rules. See Erase on page 4-12. Beeper Definitions for ADF on page 4-8 help guide you through the programming steps.

4-2

Page 169

Advanced Data Formatting (ADF)

ADF Bar Code Menu Example This section provides an example of how to enter an ADF rule to apply to scanned data. An auto parts distribution center wants to encode manufacturer ID, part number, and destination code into their own Code 128 bar codes. The distribution center also has products that carry UPC bar codes, placed there by the manufacturer. The Code 128 bar codes have the following format: MMMMMPPPPPDD Where:

M = Manufacturer ID P = Part Number D = Destination Code

The distribution center uses a PC with dedicated control characters for manufacturer ID <CTRL M>, part number <CTRL P>, and destination code <CTRL D>. At this center the UPC data is treated as manufacturer ID code. The following rules need to be entered: When scanning data of code type Code 128, send the next 5 characters, send the manufacturer ID key <CTRL M>, send the next 5 characters, send the part number key <CTRL P>, send the next 2 characters, send the destination code key <CTRL D>. When scanning data of code type UPC/EAN, send all data, send the manufacturer ID key <CTRL M>. To enter these rules, follow these steps:

4-3

Page 170

CycloneTM M2000 Series Product Reference Guide

Rule 1: The Code 128 Scanning Rule Table 4-1. Code 128 Scanning Rule Step

Bar Code

On Page

Beep Indication

1

Begin New Rule

4-11

High High

2

Code 128

4-14

High High

3

Send next 5 characters

4-26

High High

4

Send <CTRL M>

4-51

High High

5

Send next 5 characters

4-26

High High

6

Send <CTRL P>

4-51

High High

7

Send next 2 characters

4-25

High High

8

Send <CTRL D>

4-49

High High

9

Save Rule

4-11

High Low High Low

Rule 2: The UPC Scanning Rule Table 4-2. UPC Scanning Rule Step

Bar Code

On Page

Beep Indication

1

Begin New Rule

4-11

High High

2

UPC/EAN

4-15

High High

3

Send all remaining data

4-25

High High

4

Send <CTRL M>

4-51

High High

5

Save Rule

4-11

High Low High Low

If you made any mistakes while entering this rule, scan the Quit Entering Rules bar code on page 4-12. If you already saved the rule, scan the Erase Previously Saved Rule bar code on page 4-12.

4-4