Page 151

Parameter Menus

Macro PDF Transmit / Decode Mode Symbols Select only one of the four options below for handling the decoding of Macro PDF. The scanner can handle up to 64K bytes of decoded data, including any optional field information, except in the mode Transmit Each Macro PDF Symbol Decoded in Sequential Order, where there is no limit to the size of the Macro PDF set. !

Buffer All Symbols / Transmit Macro PDF When Complete activates transmission of all decode data from an entire Macro PDF sequence. Transmission does not occur until the entire Macro PDF sequence is scanned and decoded. This is the default option. If the decode data exceeds the limit of 64 symbols or 64K bytes, there is no transmission because the entire sequence has not been scanned. Use the parameter Flush Macro PDF Buffer to purge the buffer.

!

Transmit Any Symbol in Set / No Particular Order causes transmission of data from up to 1024 Macro symbols as decoded, whether it is in sequential order or not.

!

Scan in Sequence Only / Transmit in Sequence Without Buffering causes transmission of data from up to 1024 symbols within the Macro PDF sequence as decoded, provided the Macro PDF symbols are scanned in order. If you do not scan the symbols in order, an error occurs.

!

When Buffer Scans Out of Order / Transmit Scans in Order is enabled, decode data from each symbol within the Macro PDF sequence is transmitted when decoded, provided that the Macro PDF symbols are scanned in order. Decode data from symbols out of order in the Macro PDF sequence is buffered. The scanner can buffer up to 64 symbols or 64K bytes.

3-117

Page 152

CycloneTM M2000 Series Product Reference Guide

Macro PDF Transmit / Decode Mode Symbols (Continued)

Buffer All Symbols / Transmit When Complete

Transmit Any Symbol In Set / No Particular Order

Scan In Sequence Only / Transmit In Sequence Without Buffering

Buffer Scans Out Of Order/ Transmit Scans In Order

3-118

Page 153

Parameter Menus

Transmit Symbols in Codeword Format Enabling this activates transmission of each PDF symbol as directly decoded data codewords, whether that symbol is part of a macro PDF sequence or not. Note that data is output as codeword values, not as interpreted data. “Codeword values” is an ASCII representation of a number from 000 to 928 for each codeword, preceded by an escape character. This escape character is a backslash by default, but the user may change this value. For example, the codeword value 005 is sent to the host in the form of \005 for GLIs, and \C005C for ECIs. This output format is based on the AIM USA Uniform Symbology Specification for PDF417 (1994). All output codewords take up exactly 4 characters for GLIs and 6 characters for ECIs. However, there may be nondecodable characters in the PDF symbol, such as a GLI sequence. This special codeword sequence activates a certain kind of interpretation to the encoded data. Non-decodable codewords like GLIs are embedded in the output stream just like any other codeword, e.g., \927\001. Because GLIs are indistinguishable from other codewords in the output data stream, the host must intelligently recognize them as GLIs and process their interpretations. Note that when a macro PDF sequence is transmitted, the last character in the last block of data transmitted is always \922 (if selected). This indicates the end of that macro PDF transmission.

Enable Transmit In Codeword Format

Disable Transmit In Codeword Format

3-119

Page 154

CycloneTM M2000 Series Product Reference Guide

Transmit Unknown Codewords This enables using the output codeword format for transmitting any non-GLI or non-macro PDF codeword. If this is not enabled and an unknown codeword is found, a decode error beep sounds.

Transmit Unknown Codewords

Do Not Transmit Unknown Codewords

3-120

Page 155

Parameter Menus

Escape Characters This enables the backslash (\) character as an Escape character for systems that can process transmissions containing special data sequences. Scan a bar code below to either format special data (e.g., GLI escapes, MacroPDF417 Control Block optional fields) according to the GLI (Global Label Identifier) protocol or the ECI (Extended Channel Interpretation) protocol, or to disable this parameter.

ECI Protocol

GLI Protocol

None

3-121

Page 156

CycloneTM M2000 Series Product Reference Guide

Delete Character Set ECIs This parameter enables the scanner to delete any escape sequences representing Character Set ECIs (also known as GLIs) from its buffer before transmission. In many receiving systems, Character Set ECIs can be removed without affecting the way data is displayed or processed. When deletion is selected, the scanner transmits data from PDF417 and MicroPDF417 bar codes containing Character Set ECIs, even when the ECI Protocol is disabled. Scan a bar code to delete or transmit character set ECIs.

Delete Character Set ECIs

Transmit Character Set ECIs

3-122

Page 157

Parameter Menus

ECI Decoder This parameter enables the scanner to interpret any Extended Channel Interpretations (ECIs) that are supported by the scanner firmware. This parameter has no effect on symbols that were not encoded using ECIs. This version of the product supports ECIs 000900 through 000913, used for efficient encoding of Common Data Syntax Format 00-99. If this parameter is disabled, and a symbol is scanned that was encoded using an ECI escape, the scanner transmits the ECI escape followed by the uninterpreted data. Scan a bar code to enable or disable this option.

Enable ECI Decoder

Disable ECI Decoder

3-123

Page 158

CycloneTM M2000 Series Product Reference Guide

Transmit Macro PDF User-Selected Fields When enabled, the following parameters cause transmission of the specified field in subsequently scanned Macro PDF417 symbols. Unless transmission of a specific field is enabled, it is not transmitted. The options cannot be changed in the middle of a Macro PDF set entry. All user-selected fields are prefixed by \923 for GLIs, and \C923C for ECIs. Tags and examples in the following parameters demonstrate GLI protocol, but the ECI tag (\C923C) can be used instead if ECI protocol is enabled.

Transmit File Name Transmit File Name activates transmission of the file name field. The field character tag is \923\000. For example, the filename MANHOURS.WK1 is sent as: \923\000MANHOURS.WK1.

Enable File Name Transmit

Disable File Name Transmit

3-124

Page 159

Parameter Menus

Transmit Block Count Transmit Block Count activates transmission of the block count field. The field character tag is \923\001. For example, the field may be: \923\0011856.

Enable Transmit Block Count

Disable Transmit Block Count

Transmit Time Stamp Transmit Time Stamp activates transmission of the time stamp field. The field character tag is \923\002. For example, the field may be: \923\0022123443243234.

Enable Transmit Time Stamp

Disable Transmit Time Stamp

3-125

Page 160

CycloneTM M2000 Series Product Reference Guide

Transmit Sender Transmit Sender activates transmission of the sender field. The field character tag is \923\003. For example, the field may be: \923\003Symbol TechnologiesHoltsville, NY.

Enable Sender Transmit

Disable Sender Transmit

Transmit Addressee Transmit Addressee activates transmission of the addressee field. The field character tag is \923\004. For example, the field may be: \923\004AIM USA.

Enable Addressee Transmit

Disable Addressee Transmit

3-126