The text of a manual · part 11 of 11
LT 1820 Product Reference Guide, pages 101 to 105
Pages 101 to 105 of 105
The original document is the PDF (360 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LT-1820
Page 101
LT 1820 Product Reference Guide: Glossary
Dead Zone
An area within a scanner's field of view, in which specular reflection may prevent a successful decode.
Decode
To recognize a bar code symbology (e.g., UPC/EAN) and then analyze the content of the specific bar code scanned.
Decode Algorithm
A decoding scheme that converts pulse widths into data representation of the letters or numbers encoded within a bar code symbol.
Depth of Field
The range between minimum and maximum distances at which a scanner can read a symbol with a certain minimum element width.
Discrete Code
A bar code or symbol in which the spaces between characters (intercharacter gaps) are not part of the code.
Discrete 2 of 5
A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded.
EAN
European Article Number. This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail.
Element
Generic term for a bar or space.
Encoded Area
Total linear dimension occupied by all characters of a code pattern, including start/stop characters and data.
Host Computer
A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control.
IEC
International Electrotechnical Commission. This international agency regulates laser safety by specifying various laser operation classes based on power output during operation.
IEC (825) Class 1
This is the lowest power IEC laser classification. Conformity is ensured through a software restriction of 120 seconds of laser operation within any 1000 second window and an automatic laser shutdown if the scanner's oscillating mirror fails.
Intercharacter Gap
The space between two adjacent bar code characters in a discrete code.
Glossary -3
Page 102
LT 1820 Product Reference Guide: Glossary
Interleaved Bar Code A bar code in which characters are paired together, using bars to represent the first character and the intervening spaces to represent the second. Interleaved 2 of 5
A binary bar code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides for greater information density. The location of wide elements (bar/ spaces) within each group determines which characters are encoded. This continuous code type uses no intercharacter spaces. Only numeric (0 to 9) and START/STOP characters may be encoded.
LASER - Light Amplification by Stimulated Emission of Radiation
The laser is an intense light source. Light from a laser is all the same frequency, unlike the output of an incandescent bulb. Laser light is typically coherent and has a high energy density.
Laser Diode
A gallium-arsenide semiconductor type of laser connected to a power source to generate a laser beam. This laser type is a compact source of coherent light.
LED Indicator
A semiconductor diode (LED - Light Emitting Diode) used as an indicator, often in digital displays. The semiconductor uses applied voltage to produce light of a certain frequency determined by the semiconductor's particular chemical composition.
MIL
1 mil = 1 thousandth of an inch.
Misread (Misdecode) A condition which occurs when the data output of a reader or interface controller does not agree with the data encoded within a bar code symbol. Nominal
The exact (or ideal) intended value for a specified parameter. Tolerances are specified as positive and negative deviations from this value.
Nominal Size
Standard size for a bar code symbol. Most UPC/EAN codes can be used over a range of magnifications (e.g., from 0.80 to 2.00 of nominal).
Parameter
A variable that can have different values assigned to it.
Percent Decode
The average probability that a single scan of a bar code would result in a successful decode. In a well-designed bar code scanning system, that probability should approach near 100%.
Glossary -4
Page 103
LT 1820 Product Reference Guide: Glossary
Print Contrast Signal Measurement of the contrast (brightness difference) between the bars (PCS) and spaces of a symbol. A minimum PCS value is needed for a bar code symbol to be scannable. PCS = (RL - RD) / RL, where RL is the reflectance factor of the background and RD the reflectance factor of the dark bars. Programming Mode
The state in which a scanner is configured for parameter values. See Scanning Mode.
Quiet Zone
A clear space, containing no dark marks, which precedes the start character of a bar code symbol and follows the stop character.
Reflectance
Amount of light returned from an illuminated surface.
Resolution
The narrowest element dimension which can be distinguished by a particular reading device or printed with a particular device or method.
Scan Area
Area intended to contain a symbol.
Scanner
An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are: 1.Light source (laser or photoelectric cell) - illuminates a bar code. 2.Photodetector - registers the difference in reflected light (more light reflected from spaces). 3.Signal conditioning circuit - transforms optical detector output into a digitized bar pattern.
Scanning Mode
The scanner is energized, programmed, and ready to read a bar code.
Scanning Sequence
A method of programming or configuring parameters for a bar code reading system by scanning bar code menus.
Self-Checking Code
A symbology that uses a checking algorithm to detect encoding errors within the characters of a bar code symbol.
Space
The lighter element of a bar code formed by the background between bars.
Specular Reflection
The mirror-like reflection of light from a surface, which can “blind” a scanner.
Start/Stop Character
A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are normally to the left and right margins of a horizontal code.
Substrate
A foundation material on which a substance or image is placed.
Glossary -5
Page 104
LT 1820 Product Reference Guide: Glossary
Symbol
A scannable unit that encodes data within the conventions of a certain symbology, usually including start/stop characters, quiet zones, data characters, and check characters.
Symbol Aspect Ratio The ratio of symbol height to symbol width. Symbol Height
The distance between the outside edges of the quiet zones of the first row and the last row.
Symbol Length
Length of symbol measured from the beginning of the quiet zone (margin) adjacent to the start character to the end of the quiet zone (margin) adjacent to a stop character.
Symbology
The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39).
Tolerance
Allowable deviation from the nominal bar or space width.
UPC
Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which can be any of four widths. The standard symbology for retail food packages in the United States.
Visible Laser Diode (VLD)
A solid state device which produces visible laser light. Laser light emitted from the diode has a wavelength of 670 to 680 nanometers.
Glossary -6
Page 105
Tell Us WhatYou Think... We’d like to know what you think about this manual. Please take a moment to fill out this questionaire and fax this form to: (516) 738-3318, or mail to: Symbol Technologies, Inc. One Symbol Plaza M/S B-4 Holtsville, NY 11742-1300 Attn: Technical Publications Manager IMPORTANT: If you need product support, please call the appropriate customer support number provided. Unfortunately, we cannot provide customer support at the fax number above. User’s Manual Title: (please include revision level) How familiar were you with this product before using this manual? Very familiar
Slightly familiar
Not at all familiar
Did this manual meet your needs? If not, please explain.
What topics need to be added to the index, if applicable? What topics do you feel need to be better discussed? Please be specific. What can we do to further improve our manuals?
Thank you for your input - We value your comments.