For the Symbol LT-1820

Page 91

LT 1820 Product Reference Guide: Parameter Menus

8

9

BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.

ENTER

BACKSPACE

CANCEL

5-45

Page 92

LT 1820 Product Reference Guide: Parameter Menus

Communications Delays and Timeouts To enter a new delay or timeout value: 1. Scan the INTERCHARACTER DELAY bar code. 2. Enter the new value by scanning two bar codes. The first bar code scanned corresponds to the most significant digit; the second bar code corresponds to the least significant digit. The value entered must be within the 00-99 ms range. 3. Scan ENTER.

INTERCHARACTER DELAY (Range = 00-99 ms)

0

1

2

5-46

Page 93

LT 1820 Product Reference Guide: Parameter Menus

3

4

5

6

7

5-47

Page 94

LT 1820 Product Reference Guide: Parameter Menus

8

9

BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.

BACKSPACE

ENTER

CANCEL

5-48

Page 95

LT 1820 Product Reference Guide: Parameter Menus

UPC-E/UPC-A Preamble To select one of the preamble options: 1. Scan the bar code corresponding to the desired Preamble option. 2. Scan the bar code to enable or disable the option. 3. Scan ENTER.

UPC-E PREAMBLE

UPC-A PREAMBLE

NONE

SYSTEM CHARACTER

5-49

Page 96

LT 1820 Product Reference Guide: Parameter Menus

SYSTEM CHARACTER AND COUNTRY CODE

BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.

BACKSPACE

ENTER

CANCEL

5-50

Page 97

LT 1820 Product Reference Guide: Parameter Menus

Data Format To select an RS-232C transmission protocol: 1. Scan the DATA FORMAT bar code. 2. Scan the bar code that corresponds to the option desired. 3. Scan ENTER.

DATA FORMAT

7 DATA BITS (WITH PARITY)

8 DATA BITS (WITHOUT PARITY)

8 DATA BITS (WITH PARITY)

5-51

Page 98

LT 1820 Product Reference Guide: Parameter Menus

BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.

BACKSPACE

ENTER

CANCEL

5-52

Page 99

Glossary

Aperture

The opening in an optical system defined by a lens or baffle that establishes the field of view.

ASCII

American Standard Code for Information Interchange. A 7 bit-plusparity code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the U.S.

Autodiscrimination

The ability of an interface controller to determine the code type of a scanned bar code. After this determination is made, the information content can be decoded.

Bar

The dark element in a printed bar code symbol.

Bar Code Density

The number of characters represented per unit of measurement (e.g., characters per inch).

Bar Height

The dimension of a bar measured perpendicular to the bar width.

Bar Width

Thickness of a bar measured from the edge closest to the symbol start character to the trailing edge of the same bar.

Baud Rate

A measure of the data flow or number of signaling events occurring per second. When one bit is the standard "event," this is a measure of bits per second (bps). For example, a baud rate of 50 means transmission of 50 bits of data per second.

Bit

Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning.

Byte

On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character.

Glossary -1

Page 100

LT 1820 Product Reference Guide: Glossary

CDRH

Center for Devices and Radiological Health. A federal agency responsible for regulating laser product safety. This agency specifies various laser operation classes based on power output during operation.

CDRH Class 1

This is the lowest power CDRH laser classification. This class is considered intrinsically safe, even if all laser output were directed into the eye's pupil. There are no special operating procedures for this class.

CDRH Class 2

No additional software mechanisms are needed to conform to this limit. Laser operation in this class poses no danger for unintentional direct human exposure.

Character

A pattern of bars and spaces which either directly represents data or indicates a control function, such as a number, letter, punctuation mark, or communications control contained in a message.

Character Set

Those characters available for encodation in a particular bar code symbology.

Check Digit

A digit used to verify a correct symbol decode. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC but are optional for other symbologies. Using check digits decreases the chance of substitution errors when a symbol is decoded.

Codabar

A discrete self-checking code with a character set consisting of digits 0 to 9 and six additional characters: ( - $ : / , +).

Code 128

A high density symbology which allows the controller to encode all 128 ASCII characters without adding extra symbol elements.

Code 3 of 9 (Code 39) A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9, and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow. Code 93

An industrial symbology compatible with Code 39 but offering a full character ASCII set and a higher coding density than Code 39.

Code Length

Number of data characters in a bar code between the start and stop characters, not including those characters.

Continuous Code

A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code. The absence of gaps allows for greater information density.

Glossary -2