LT 1806 (Keyboard Wedge/Synapse) Product Reference Guide: Chapter 4 Programming the LT 1806, pages 19 to 27

Pages 19 to 27 of 105, from LT 1806 (Keyboard Wedge/Synapse) Product Reference Guide

The original document is the PDF (636 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LT-1806

Page 19

Chapter 4 Programming the LT 1806 Before programming the scanner, follow the instructions in Chapter 1: Setting Up the LT 1806. If the default values suit your requirements, scan the SET DEFAULT bar code. An LT 1806 is programmed for parameters other than default values by scanning sequences of bar codes. Chapter 5: Parameter Menus contain all the bar codes necessary to program the scanner for each parameter selection.

Scanning Sequences A scanning sequence establishes a value for one parameter type. During a scanning sequence, scan bar codes for a parameter type, a parameter value, and ENTER. The Scanning Sequence Flowchart on page 4-3 illustrates the process.

Scanning Sequence Examples To program the scanner for all default settings except for two parameters, DECODE UPC ONLY (NOT EAN) and INTERCHARACTER DELAY, first scan the SET DEFAULT bar code. The default for DECODE UPC ONLY (NOT EAN) is DISABLE; to ENABLE this, scan the three bar codes in the order listed below: SCAN

YOU WILL HEAR . . .

1. DECODE UPC ONLY (NOT EAN)

Short high tone

2. ENABLE

Short high tone

3. ENTER

Hi/Lo/Hi/Lo warble

After the last scan in a successful scanning sequence (ENTER), the warble sound (i.e., hi/lo/hi/lo) indicates that the scanner has been successfully programmed for the selected parameter. See Beeper Definitions on page 4-13.

4-1

Page 20

LT 1806 Product Reference Guide: Programming the LT 1806

To set the INTERCHARACTER DELAY parameter scan a two digit numeric entry. Note that single digit entries must have a leading zero. The INTERCHARACTER DELAY default is 00 ms; in this example you want to set it to 2 ms. To program the scanner for a 2 ms INTERCHARACTER DELAY scan the four bar codes listed below. SCAN

YOU WILL HEAR . . .

1. INTERCHARACTER DELAY

Short high tone

2. 0

Short high tone

3. 2

Short high tone

4. ENTER

Hi/Lo/Hi/Lo warble

Errors While Scanning Don’t worry if you make an error during a scanning sequence. There are two special-purpose bar codes, BACKSPACE and CANCEL, to help you. Scanning the BACKSPACE bar code erases the value of the previous bar code scanned but keeps you within the scanning sequence for a parameter type. Scanning CANCEL removes you from the current sequence so that you can start again.

4-2

Page 21

LT 1806 Product Reference Guide: Programming the LT 1806

Scanning Sequence Flowchart Re-Select

START

Re-Select

Incorrect parameter type

CANCEL

SELECT AND SCAN PARAMETER TYPE

GOOD

Re-Select

No Good CANCEL

SELECT AND SCAN (PARAMETER VALUE)

No Good

GOOD

SCAN ENTER (Parameter is Set)

Figure 4-1. Scanning Sequence Flowchart

4-3

BACKSPACE

Page 22

LT 1806 Product Reference Guide: Programming the LT 1806

Parameter Descriptions See Standard Defaults on page 4-11 for the range of values and default settings for each parameter type.

Set Parameter Defaults Scanning the SET DEFAULT bar code returns all parameters to the default values listed in Parameter Selections.

Keyboard Type Select the type of keyboard to be used with the LT 1806. Even if default setting for all parameters is selected, a keyboard type must be selected, or the unit will not operate. Selecting a keyboard type automatically returns prefix and suffix settings to their default values.

National Type This option applies only to the IBM PC XT/AT/PS2. Other keyboard types are available via Synapse “Smart Cables”. Use this option to select a national keyboard type. Options are: National Type

Identifier

National Type

Identifier

U.K. English French German Spanish Portuguese

0 1 2 3 4

Brazilian Italian Dutch U.S. English

5 6 7 8

Note: PC/XT Brazilian and Portuguese layouts are not supported.

Numeric Keypad Emulation This option applies only to the IBM PC XT/AT/PS2. If this is enabled, keystrokes are emulated by sending the ASCII code equivalent of the specific character using the ALTERNATE key and the numeric key pad.

4-4

Page 23

LT 1806 Product Reference Guide: Programming the LT 1806

When enabled, the unit: • Emulates all national keyboards (the user does not have to select a

NATIONAL KEYBOARD option.) • Emulates all characters, regardless of the status of the CAPS LOCK key. • Performs the emulation slower than in non-numeric key pad option, because it has to emulate several key strokes for each character.

Break Key Code Transmission When this parameter is enabled, both “operate” (“make”) and “release” (“break”) key codes are transmitted. When it is disabled, only “operate” (“make”) key codes are sent. This parameter only affects scanned data, not the key codes passed through from the keyboard.

Code Types The bar code menu selections enable the scanner to decode any or all of the following symbologies: • UPC Versions A and E (EAN 8 and 13)

• Code 39

• Code 39 Full ASCII

• Interleaved 2 of 5

• Discrete 2 of 5

• Code 93

• Code 128

• Codabar

• UCC/EAN 128

The scanner autodiscriminates between all of the above code types, except for between Code 39 and Code 39 Full ASCII. Select whether UPC/EAN is to be decoded with or without supplementals. See Decode UPC/EAN Supplementals on page 4-7 for details. If you want to add Discrete 2 of 5 or Interleaved 2 of 5, check the previously enabled lengths. To set lengths for these codes, see the FIXED LENGTHS FOR CODE 2 OF 5 section of the parameter menus.

4-5

Page 24

LT 1806 Product Reference Guide: Programming the LT 1806

Fixed Lengths for Code 2 of 5 Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine the number of characters represented in each code type by counting the number of printed (i.e., human readable) digits that represent a bar code label. One or two lengths (Length 1, Length 2) for either code type may be set, as needed. If the default setting is satisfactory it need not be reset. Set one or both lengths, one per scanning sequence. LENGTH 1 may range from 01-31 and LENGTH 2 from 00-31.

Decode Options Transmit UPC-E/UPC-A Check Digit If enabled, decoded UPC-E or UPC-A symbols are transmitted with check digit.

Decode UPC Only (Not EAN) If enabled, this option limits LT 1806 UPC/EAN decode capability to UPC versions only. It disables EAN decode capability.

Convert UPC-E to UPC-A If enabled, this parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data is subject to UPC programming selections (e.g., Preamble, Check Digit).

Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN-13 for transmission to the host. To enable this option, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.

EAN Zero Extend If selected, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.

4-6

Page 25

LT 1806 Product Reference Guide: Programming the LT 1806

CLSI Editing If selected, this parameter inserts a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. The symbol length does not include start and stop characters.

NOTIS Editing If selected, this option strips the start and stop characters from decoded Codabar symbols.

Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single-character prefix already selected, the code ID character is appended as a prefix to the decode. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5 or Discrete 2 of 5 IATA; K = UCC/EAN128.

Transmit “No Decode” Character This feature gives you the option to transmit “NR” when a symbol does not decode. Prefixes and suffixes enabled are appended around this character. Note: This option is available in Triggered Mode only.

Decode UPC/EAN Supplementals Select whether UPC/EAN is decoded with or without supplemental characters, or whether the unit autodiscriminates between the two. Supplementals are additionally appended characters, according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+5). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/ EAN plus supplemental symbol, the UPC/EAN is decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LT 1806 will, after additional processing to ensure a good decode, transmit either.

4-7

Page 26

LT 1806 Product Reference Guide: Programming the LT 1806

Beep After Good Decode If enabled, the unit beeper sounds during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. See Beeper Definitions on page 4-13.

Beeper Volume Use this parameter to program the beeper for Full or Low volume.

Trigger Mode (for triggered models only) Select whether you would like to use the scanner with the trigger (Triggered Mode), or if you’d like the laser to be in a constant blinking state (Triggerless Mode).

Decode Redundancy Use this parameter to indicate whether the scanner must read a bar code one time (LEVEL 0), two times (LEVEL 1), or three times (LEVEL 2) before decoding it. A higher level of redundancy ensures the accuracy of a decode in, for example, poor quality symbols.

Scan Data Transmission Format Options for scan data transmission formats can be selected by the user. This parameter is used in conjuction with the Prefix/Suffix parameters for both onboard hosts and Synapse configurations. The following are standard selections: Standard: Option 1: Option 2: Option 3:

<scan data> <scan data> <SUFFIX> <PREFIX> <scan data> <SUFFIX> <PREFIX> <scan data>

Prefix/Suffix (On-board hosts) If desired, select an appropriate prefix (start-of-text character)/suffix to append to transmitted data. See Table 4-3 beginning on page 4-17.

4-8

Page 27

LT 1806 Product Reference Guide: Programming the LT 1806

Prefix/Suffix (Synapse) When using Synapse, the prefix or suffix appended to scan data for data editing is set by scanning a 4-digit number (i.e., 4 bar codes) that corresponds to key codes for various terminals. See Table 4-4 beginning on page 4-18.

Communications Delays and Timeouts (Intercharacter Delay) Select the intercharacter delay option matching host device requirements. Select from no delay to a 99 ms delay between the transmission of each character.

Prefix/Suffix Transmit Delay This parameter specifies a delay period to occur after any prefix or suffix is transmitted. The proper delay period varies according to host terminal requirements. In some cases, no delay is necessary. The delay period can range from 00 to 9.9 seconds.

UPC A and E Preamble(s) Three options are given for the lead-in characters of decoded UPC-A or UPCE symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble

The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.

Scan and Store (Code 39 Buffering) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered.

4-9