Page 11
Chapter 2 Scanning with the LT 1806 Scanning • Make sure the scanner is connected to the controller or portable data terminal before you turn on the system. • Make sure the symbol you want to scan is within the LT 1806 scanning range. (See LT 1806 Decode Zone on page 2-2.) • If the scanner is in triggerless mode, simply bring the scanner to the bar code. The scan beam is in a constant blinking state which becomes steady when the scanner is decoding a bar code. • If the scanner is in triggered mode, bring the scanner to the bar code and press the trigger. The scan beam (and red LED on the top of the scanner) illuminates for approximately 1 second, or until a successful decode. • The scan beam must cross every bar and space on the symbol. RIGHT
WRONG
012345
012345
• When the symbol has been decoded, you hear a short, high-tone beep, and the green decode LED lights.
2-1
Page 12
LT 1806 Product Reference Guide: Scanning with the LT 1806
LT 1806 Decode Zone 3 in 7.62 cm 2.5 in 6.35 cm 2 in 5.08 cm 1.5 in 3.81 cm
.5 in 1.27 cm 0 in 0 cm .5 in 1.27 cm 1 in 2.54 cm 1.5 in 3.81 cm 5.5 mil (0"-.75")
2 in 5.08 cm
6 mil (0" - 1")
2.5 in 6.35 cm
7.5 mil (0" - 2.2")
3 in 7.62 cm
13 mil (0"-5") (100% UPC/EAN)
0 in
.5 in
1 in
1.5 in
2 in
2.5 in
3 in
3.5 in
4 in
4.5 in
5 in
0 cm
1.27 cm
2.54 cm
3.81 cm
5.08 cm
6.35 cm
7.62 cm
8.89 cm
10.16 cm
11.43 cm
12.70 cm
DISTANCE FROM SCANNER
Figure 2-1. LT 1806 Decode Zone
2-2
WIDTH OF FIELD
SCANNER NOSE
1 in 2.54 cm
Page 13
Chapter 3 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • Do not allow any abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window. • Do not remove the nose of the scanner.
3-1
Page 14
LT 1806 Product Reference Guide: Maintenance and Specifications
What If... Nothing happens when you follow the operating instructions. You Should • Check the system power. • Make sure the scanner is programmed for the terminal in use. • Make sure the controller is programmed to decode bar codes of the symbology you are scanning. • Check for loose cable connections. • Make sure the symbol is not defaced. • Try scanning test symbols of the same code type.
Scanned data is incorrectly displayed on the terminal. You Should • Make sure that the system was programmed for the correct keyboard type. • Make sure that the CAPS LOCK key is off.
Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center at one of the telephone numbers listed in About This Manual.
3-2
Page 15
LT 1806 Product Reference Guide: Maintenance and Specifications
Accessories Standard Accessories Part Number 70-32538-0X 70-31613-0X 50-11400-007
Description LT 1806 Product Reference Guide LT 1850/1806 Quick Reference Guide Shipping Box
Power Supply Part Number 50-14000-008 50-14000-009
Description 110V, 60Hz 220V, 50Hz
Cables Listed below are the cables required for each host: Y-Cable
Power Supply?
Adapter Kit
IBM PS/2 25/30/30-386
25-31828-01
Yes
N/A
IBM PS/2 50/55SX/60/ 65SX/70/80*
25-31828-01
No
N/A
NCR 7052 K.W.
25-31828-01
Yes
N/A
IBM PC AT/XT and PC Clones
25-31828-01
No
KT-32903-01
Terminal/PC
*These PS/2 systems may require an external power supply if multiple peripheral devices or expansion cards are installed. The system needs to supply a minimum of 160 mA for proper LT 1806 operation.
3-3
Page 16
LT 1806 Product Reference Guide: Maintenance and Specifications
Synapse Adapter Cables Hosts using Synapse cables require one of the following Adapter Cables: Part Number 25-31617-01
Description 6-foot Straight Cable
Optional Accessories Part Number 20-12769-01 20-08414-01 20-08415-01 21-08288-02 23-08253-01 20-08416-01
Description Hands-Free Stand - Desk Mount (non-adjustable) Hands-Free Stand - Free Standing (adjustable) Hands-Free Stand - ECR Mount (adjustable) Desk-Mount Stand Wall-Mount Stand Holster/Belt Clip
3-4
Page 17
LT 1806 Product Reference Guide: Maintenance and Specifications
Technical Specifications ITEM
DESCRIPTION
Power Requirements
5 VDC ±10%; 120 mA average current (160 mA peak)
Decode Capability
The LT 1806 can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, UCC/EAN 128, Discrete 2 of 5, and Code 93. Set code length(s) for any 2 of 5 code type. Full autodiscrimination as required.
Beeper Operation
User-selectable: Enable, Disable
Beeper Volume
User-selectable: Full Volume, Low Volume
Decode Depth of Field
Maximum typical working distance is 5.0 in. (12.70 cm) (100% UPC/EAN); minimum element width resolution is 5.5 mils
Scan Repetition Rate
40 (± 3) scans/sec (bidirectional)
Skew Tolerance
± 35˚ min. (from normal)
Pitch Tolerance
-20˚ to +60° (from normal)
Print Contrast Minimum
25% minimum reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure to normal office and factory lighting conditions, as well as direct exposure to sunlight.
Output Presentation
Host keystroke format
Durability
5 ft (152 cm) drops to concrete
Operating Temperature
32˚ to 104˚ F (0˚ to 40˚ C)
Storage Temperature
-40˚ to 140˚ F (-40˚ to 60˚ C)
Straight Cable Length
6 ft (183 cm)
Weight (without cable)
6.0 oz (170 gm)
3-5
Page 18
LT 1806 Product Reference Guide: Maintenance and Specifications
LT 1806 Dimensions Nose Width: 2.8 in (7.1 cm)
Length: 8.0 in (20.3 cm)
Table Height: 2.4 in (6.1 cm)
Handle Width: 2.0 in (5.1 cm)
Height: 1.8 in (4.6 cm)
Figure 3-1. LT 1806 Dimensions 3-6