Page 11

Chapter 2 Scanning with the LT 1806 Scanning • Make sure the scanner is connected to the controller or portable data terminal before you turn on the system. • Make sure the symbol you want to scan is within the LT 1806 scanning range. (See LT 1806 Decode Zone on page 2-2.) • If the scanner is in triggerless mode, simply bring the scanner to the bar code. The scan beam is in a constant blinking state which becomes steady when the scanner is decoding a bar code. • If the scanner is in triggered mode, bring the scanner to the bar code and press the trigger. The scan beam (and red LED on the top of the scanner) illuminates for approximately 1 second, or until a successful decode. • The scan beam must cross every bar and space on the symbol. RIGHT

WRONG

012345

012345

• When the symbol has been decoded, you hear a short, high-tone beep, and the green decode LED lights.

2-1

Page 12

LT 1806 Product Reference Guide: Scanning with the LT 1806

LT 1806 Decode Zone 3 in 7.62 cm 2.5 in 6.35 cm 2 in 5.08 cm 1.5 in 3.81 cm

.5 in 1.27 cm 0 in 0 cm .5 in 1.27 cm 1 in 2.54 cm 1.5 in 3.81 cm 5.5 mil (0"-.75")

2 in 5.08 cm

6 mil (0" - 1")

2.5 in 6.35 cm

7.5 mil (0" - 2.2")

3 in 7.62 cm

13 mil (0"-5") (100% UPC/EAN)

0 in

.5 in

1 in

1.5 in

2 in

2.5 in

3 in

3.5 in

4 in

4.5 in

5 in

0 cm

1.27 cm

2.54 cm

3.81 cm

5.08 cm

6.35 cm

7.62 cm

8.89 cm

10.16 cm

11.43 cm

12.70 cm

DISTANCE FROM SCANNER

Figure 2-1. LT 1806 Decode Zone

2-2

WIDTH OF FIELD

SCANNER NOSE

1 in 2.54 cm

Page 13

Chapter 3 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • Do not allow any abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window. • Do not remove the nose of the scanner.

3-1

Page 14

LT 1806 Product Reference Guide: Maintenance and Specifications

What If... Nothing happens when you follow the operating instructions. You Should • Check the system power. • Make sure the scanner is programmed for the terminal in use. • Make sure the controller is programmed to decode bar codes of the symbology you are scanning. • Check for loose cable connections. • Make sure the symbol is not defaced. • Try scanning test symbols of the same code type.

Scanned data is incorrectly displayed on the terminal. You Should • Make sure that the system was programmed for the correct keyboard type. • Make sure that the CAPS LOCK key is off.

Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center at one of the telephone numbers listed in About This Manual.

3-2

Page 15

LT 1806 Product Reference Guide: Maintenance and Specifications

Accessories Standard Accessories Part Number 70-32538-0X 70-31613-0X 50-11400-007

Description LT 1806 Product Reference Guide LT 1850/1806 Quick Reference Guide Shipping Box

Power Supply Part Number 50-14000-008 50-14000-009

Description 110V, 60Hz 220V, 50Hz

Cables Listed below are the cables required for each host: Y-Cable

Power Supply?

Adapter Kit

IBM PS/2 25/30/30-386

25-31828-01

Yes

N/A

IBM PS/2 50/55SX/60/ 65SX/70/80*

25-31828-01

No

N/A

NCR 7052 K.W.

25-31828-01

Yes

N/A

IBM PC AT/XT and PC Clones

25-31828-01

No

KT-32903-01

Terminal/PC

*These PS/2 systems may require an external power supply if multiple peripheral devices or expansion cards are installed. The system needs to supply a minimum of 160 mA for proper LT 1806 operation.

3-3

Page 16

LT 1806 Product Reference Guide: Maintenance and Specifications

Synapse Adapter Cables Hosts using Synapse cables require one of the following Adapter Cables: Part Number 25-31617-01

Description 6-foot Straight Cable

Optional Accessories Part Number 20-12769-01 20-08414-01 20-08415-01 21-08288-02 23-08253-01 20-08416-01

Description Hands-Free Stand - Desk Mount (non-adjustable) Hands-Free Stand - Free Standing (adjustable) Hands-Free Stand - ECR Mount (adjustable) Desk-Mount Stand Wall-Mount Stand Holster/Belt Clip

3-4

Page 17

LT 1806 Product Reference Guide: Maintenance and Specifications

Technical Specifications ITEM

DESCRIPTION

Power Requirements

5 VDC ±10%; 120 mA average current (160 mA peak)

Decode Capability

The LT 1806 can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, UCC/EAN 128, Discrete 2 of 5, and Code 93. Set code length(s) for any 2 of 5 code type. Full autodiscrimination as required.

Beeper Operation

User-selectable: Enable, Disable

Beeper Volume

User-selectable: Full Volume, Low Volume

Decode Depth of Field

Maximum typical working distance is 5.0 in. (12.70 cm) (100% UPC/EAN); minimum element width resolution is 5.5 mils

Scan Repetition Rate

40 (± 3) scans/sec (bidirectional)

Skew Tolerance

± 35˚ min. (from normal)

Pitch Tolerance

-20˚ to +60° (from normal)

Print Contrast Minimum

25% minimum reflectance differential, measured at 675 nm.

Ambient Light Immunity

Immune to direct exposure to normal office and factory lighting conditions, as well as direct exposure to sunlight.

Output Presentation

Host keystroke format

Durability

5 ft (152 cm) drops to concrete

Operating Temperature

32˚ to 104˚ F (0˚ to 40˚ C)

Storage Temperature

-40˚ to 140˚ F (-40˚ to 60˚ C)

Straight Cable Length

6 ft (183 cm)

Weight (without cable)

6.0 oz (170 gm)

3-5

Page 18

LT 1806 Product Reference Guide: Maintenance and Specifications

LT 1806 Dimensions Nose Width: 2.8 in (7.1 cm)

Length: 8.0 in (20.3 cm)

Table Height: 2.4 in (6.1 cm)

Handle Width: 2.0 in (5.1 cm)

Height: 1.8 in (4.6 cm)

Figure 3-1. LT 1806 Dimensions 3-6