Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 28

LS 9100 Product Reference Guide: Chapter 4 Programming

Pages 43 to 50 of 249, from LS 9100 Product Reference Guide

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-9100

Page 43

Chapter 4 Programming Defaults The LS 9100 is shipped with the default settings listed on the next few pages. These default values are stored in non-volatile memory (Flash) and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values will replace the standard default values in memory. The default parameter values can be recalled by scanning the SET DEFAULT bar code. The definition of each parameter is provided with the corresponding programming bar code(s) on the page indicated in the following default tables.

4-1

Page 44

LS 9100 Product Reference Guide

Table 4-1. Host Types and Options Parameter

Default

Page Number

No Host

5-2

Baud Rate (RS-232)

9600

5-11

Parity (RS-232)

Even

5-19

Check Parity (RS-232)

Disable

5-24

Hardware Handshaking (RS232)

None

5-26

Software Handshaking (RS232)

None

5-32

Host Serial Response Timeout (RS-232)

2.0 seconds

5-37

Host Serial RTS Line State (RS-232)

Low

5-38

Stop Bit Select (RS-232)

1

5-40

ASCII Format (RS-232)

8 bit

5-42

Beep on <BEL> (RS-232)

Disable

5-44

Host Type

4-2

Page 45

Programming

Table 4-2. Code Types and Options Parameter

Default

Page

UPC-A

Enable

5-46

UPC-E

Enable

5-48

EAN-8

Enable

5-50

EAN-13

Enable

5-52

Decode UPC/EAN Supplementals

Ignore

5-54

UCC/EAN Coupon Code

Disable

5-57

Code 128

Enable

5-59

Any Length

5-61

UCC/EAN-128

Enable

5-62

Code 39

Enable

5-64

Set Length(s) for Code 39

1 to 55

5-66

Code 39 Check Digit Verification

Disable

5-70

Code 39 Full ASCII Conversion

Disable

5-72

Interleaved 2 of 5

Disable

5-75

14

5-77

Codabar

Disable

5-81

Set Lengths for Codabar

5-55

5-83

Lengths for Code 128

Set Length(s) for I 2 of 5

4-3

Page 46

LS 9100 Product Reference Guide

Table 4-2. Code Types and Options Parameter

Default

Page

CLSI Editing

Disable

5-87

NOTIS Editing

Disable

5-89

Table 4-3. Custom Tailoring Parameter

Default

Page Number

High Frequency

5-91

Host Laser Off Delay

0.2 seconds

5-94

Time out between reads, same symbol

0.6 seconds

5-95

Time out between reads, different symbols

0.2 seconds

5-96

Disable

5-97

Decode Attempt Duration

2.0 seconds

5-99

Time Delay to Low Power Mode

30 minutes

5-100

Beeper Tone

Decode Buffering

4-4

Page 47

Programming

Table 4-4. Decode Options Parameter

Default

Page Number

UPC/EAN Predecode block

Reject

5-104

UPC/EAN Security Levels 0-3

0

5-106

Disable

5-110

Decode UPC/EAN Redundancy (only when autodiscrimination is enabled)

20

5-112

Linear Code Type Security Levels 1-4

2

5-113

Code 128 Decode Performance (Levels 1-3)

Enable, Level 3

5-117

Code 39 Decode Performance (Levels 1-3) (for fixed length only)

Enable, Level 3

5-122

Linear UPC/EAN Decode

4-5

Page 48

LS 9100 Product Reference Guide

Table 4-5. Data Transmission Formats Parameter

Default

Page

Transmit UPC-A Check Digit

Enable

5-127

Transmit UPC-E Check Digit

Enable

5-129

UPC-A Preamble

System Character

5-131

UPC-E Preamble

System Character

5-134

Convert UPC-E to A

Disable

5-137

EAN-8 Zero Extend

Disable

5-139

Convert EAN-8 to EAN-13 Type

EAN-13 Type

5-141

Beep After Good Decode

Enable

5-143

0

5-145

None

5-146

7013 (<CR/LF> for serial)

5-149

Data Transmission Formats

Data as is

5-151

Ignore Unknown Characters

Enable

5-158

Intercharacter Delay Transmit Code ID Character (Symbol/AIM/None) Prefix/Suffix Values

4-6

Page 49

Programming

Audible Feedback During the programming process the LS 9100 scanner will emit a series of beep tones and sequences to help you determine if you are proceeding correctly. The chart below defines all possible tones and sequences. Table 4-6. Beeper Definitions Beeper Tone/Sequence

Indication

1 Beep - Lo/Hi tone

Input error, incorrect bar code or CANCEL scanned, incorrect sequence followed.

1 Beep - Hi/Lo tone

Keyboard parameter selected. Enter value using bar code keypad.

1 Beep - Hi/Lo/Hi/Lo tone

Successful program exit with change in parameter setting.

4-7

Page 50

LS 9100 Product Reference Guide

4-8