Page 229
Appendix A Programming Reference UCC/EAN-128 UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields. When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character, and replaces other FNC 1 characters with the ASCII 29 GS control character. When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. Standard Code 128 bar codes which do not have a leading FNC 1 may still be used, but are not encoded according to the EAN128 convention. Standard Code 128 and UCC/EAN-128 may be mixed in an application. The LS 9100 autodiscriminates between these symbols, and can enable or disable one or both
A-1
Page 230
LS 9100 Product Reference Guide code types via bar code menus. The following table indicates the behavior of the LS 9100 in each of the four possible parameter settings.
Table A-1. Code 128 - UCC/EAN 128 Standard Code 128
UCC/ EAN-128
Disable
Disable
No Code 128 symbols can be read.
Disable
Enable
Read only symbols with leading FNC 1. Examples: FNC1ABCDFNC1E is read as ABCD29E AFNC1BCDFNC1E is read as ABCD29E FNC1FNC1ABCDFNC1E is read as ABCD29E ABCDFNC1E can not be read ABCDE can not be read
A-2
Effect and Example
Page 231
Programming Reference
Table A-1. Code 128 - UCC/EAN 128 (Continued) Standard Code 128
UCC/ EAN-128
Enable
Disable
Read only symbols without leading FNC 1. Examples: FNC1ABCDFNC1E can not be read AFNC1BCDFNC1E can not be read FNC1FNC1ABCDFNC1E can not be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE
Enable
Enable
Read both types of symbols. Examples: FNC1ABCDFNC1E is read as ABCD29E AFNC1BCDFNC1E is read as ABCD29E FNC1FNC1ABCDFNC1E is read as ABCD29E ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE
Effect and Example
A-3
Page 232
LS 9100 Product Reference Guide
AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character (see Table 1) m = Modifier Character (see Table 2)
Table A-2. Code Characters
A-4
Code Character
Code Type
A
Code 39
C
Code 128/EAN-128
E
UPC/EAN
I
Interleaved 2 of 5
F
Codabar
S
Discrete 2 of 5, IATA
G
Code 93
H
Code 11
T
Code 49
M
MSI/Plessey
X
Bookland, Trioptic Code 39, Coupon, NW7
Page 233
Programming Reference
AIM Modifier Identifiers The modifier character is the sum of the applicable option values based on the following table. Table A-3. Modifier Characters Code Type Code 39
Option Value
Option
0
No Check Character or Full ASCII processing
1
Reader has checked one check character
2
Reader has stripped check character
4
Reader has performed Full ASCII character conversion
Example: A Full ASCII bar code with check character W, A+I+MI+DW, can be transmitted as ]A7AimId where 7 = (1+2+4).
A-5
Page 234
LS 9100 Product Reference Guide
Table A-3. Modifier Characters (Continued) Code Type Code 128
Option Value
Option
0
Standard data packet. No Function code 1 in first symbol position.
1
Function code 1 in first symbol character position.
2
Function code 1 in second symbol character position.
Example: A Code (EAN) 128 bar code with Function 1 character in the first position, Fcnt1AimId is transmitted as ]C1AimId.
UPC/ EAN
0
Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).
1
Two digit supplement data only.
2
Five digit supplement data only.
4
EAN-8 data packet.
Example: A UPC-A bar code 012345678905 is transmitted as ]E00012345678905.
A-6
Page 235
Programming Reference
Table A-3. Modifier Characters (Continued) Code Type I 2 of 5
Example:
Option Value
Option
0
No check digit processing.
1
Reader has checked check digit.
2
Reader has stripped check digit before transmission.
An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123.
According to AIM standards, a UPC with supplemental bar code is transmitted in one of the following formats: ]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) or ]E2 (supplemental) (terminator) ]E0 (UPC chars) (terminator) In the LS 9100, however, the format is changed to: ]E0 (UPC chars) ]E2 (supplemental) Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a 21-character string, ]E00012345678905]E110.