For the Symbol LS-9100

Page 141

Parameters

Custom Tailoring Beeper Tone To select a decode beep frequency (tone), scan the LOW FREQUENCY, MEDIUM FREQUENCY, or HIGH FREQUENCY bar code.

LOW FREQUENCY

5-91

Page 142

LS 9100 Product Reference Guide

Beeper Tone (Continued)

MEDIUM FREQUENCY

5-92

Page 143

Parameters

Beeper Tone (Continued)

HIGH FREQUENCY

5-93

Page 144

LS 9100 Product Reference Guide

Host Laser Off Delay This parameter sets the minimum time between decodes. For example, if this parameter is programmed for a one second time-out, the unit does not decode again until one second after a successful decode. It is programmable in 0.1 sec increments from 0.0 to 9.9 sec. Scan the bar code below to select a host laser off delay. Next scan two bar codes from Numeric Bar Codes beginning on page 5-160. Note: If you occasionally hear four error beeps while using your scanner, try increasing the Host Laser Off Delay.

HOST LASER OFF DELAY

5-94

Page 145

Parameters

Time-out Between Decodes, Same Symbol This parameter sets the minimum time between decodes of the same symbol. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. (Setting this above 0.4 seconds is recommended.) Scan the bar code below to select a new time-out. Next scan two bar codes from Numeric Bar Codes beginning on page 5-160, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-170.

TIME-OUT BETWEEN SAME SYMBOL

5-95

Page 146

LS 9100 Product Reference Guide

Time-out Between Decodes, Different Symbols This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. Scan the bar code below, then scan two bar codes from Numeric Bar Codes beginning on page 5-160, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-170.

TIME-OUT BETWEEN DIFFERENT SYMBOLS

5-96

Page 147

Parameters

Decode Buffering When this parameter is enabled, successive decodes are buffered by the scanner. This is useful when the host takes a long time to receive and/or process a symbol. When disabled, the scanner waits until a decoded symbol is transmitted to the host before processing another symbol.

ENABLE DECODE BUFFERING

5-97

Page 148

LS 9100 Product Reference Guide

Decode Buffering (Continued)

DISABLE DECODE BUFFERING

5-98

Page 149

Parameters

Decode Attempt Duration This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds. (Setting this between 1.0 and 3.0 seconds is recommended.) Scan the bar code below to select a new time-on. Next scan two bar codes from Numeric Bar Codes beginning on page 5-160. If you make an error, or wish to change your selection, scan CANCEL on page 5-170.

DECODE ATTEMPT DURATION

5-99

Page 150

LS 9100 Product Reference Guide

Time Delay to Low Power Mode This parameter sets the time the scanner remains active after any scanning activity. Scan one of the four options. Depending on the selection, the scanner enters a low power mode 15, 30, 60 or 90 minutes after the last attempted decode. To awaken the scanner, present the bar code you wish to scan to the scan window. If you make a mistake, scan CANCEL on page 5-170.

15 MINUTES