Page 101
Programming the LS 6800
Programmable Raster Height and Raster Expansion Speed The height of the laser raster pattern and the rate at which the raster expands to that height can be programmed by using the two associated bar codes, Raster Height and Raster Expansion Speed. Note that the actual height and expansion rate are directly, though not linearly, proportional to their respective parameter values. This parameter is intended for very specific applications, and is usually not necessary. Note also that these parameters are in effect only when Programmable Raster or Always Raster is enabled. Select the laser pattern’s height and/or rate of expansion. 1. Scan the bar code for either RASTER HEIGHT or RASTER EXPANSION SPEED below. 2. To represent a two-digit value, scan two bar codes from Numeric Bar Codes beginning on page 5-96. Valid values are between 01 and 15. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.
<FN3>30N032010F RASTER HEIGHT (Default 15)
RASTER EXPANSION SPEED (Default 11) <FN3>30N022010F
5-61
Page 102
LS 6800 Product Reference Guide
Aiming Modes Select an aiming mode: aiming with a dot pattern, or with a slab raster pattern. Note that aiming modes do not work with the Always Raster scanning option.
Aiming Dot Option A trigger pull creates the single dot aiming pattern, which lasts for a fixed interval. This dot can easily be seen in outdoor or high ambient light environments. A slab raster pattern or an open raster pattern appears next, depending on the programmed scanning option. There are two programmable timeout periods for this option, normal and extended.
Slab Raster Option A trigger pull creates the slab raster pattern. If the target is a 1-D bar code, the pattern never gets beyond a slab raster. If the target bar code is PDF417, the pattern opens up to an optimized raster pattern as soon as the scanner is properly aligned over the bar code.
<FN3>2051B01 AIMING DOT (Normal Timeout)
<FN3>2051B02
5-62
<FN3>2051B00
SLAB RASTER
AIMING DOT (Extended Timeout)
Page 103
Programming the LS 6800
Time Delay to Low Power Mode Select the time the scanner remains continually on after any scanning attempt. If another bar code is not presented within the programmed time, the laser blinks to save power. This parameter only applies to Continuous and Blinking modes.
<FN3>2051000
2 MINUTE DELAY
<FN3>2051001
1 MINUTE DELAY
<FN3>2051002
30 SECOND DELAY
3 MINUTE DELAY <FN3>2051003
5-63
Page 104
LS 6800 Product Reference Guide
Timeout Options Timeout Between Decodes, Same Symbol Timeout Between Decodes, Different Symbols Select the timeouts between decodes for the same or different symbols. This is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended interval for the same symbol option is 0.6 seconds. 1. Scan the option bar code you wish to set. 2. Scan two bar codes from Numeric Bar Codes beginning on page 5-96 which correspond to the desired interval, in 0.1 second increments. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.
<FN3>3050120063 TIMEOUT BETWEEN DECODES THE SAME SYMBOL
TIMEOUT BETWEEN DECODES DIFFERENT SYMBOLS <FN3>3050D20063
5-64
Page 105
Programming the LS 6800
Security Options Decode UPC/EAN Supplemental Redundancy With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to twenty times. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected. 1. Scan the bar code below to select a decode redundancy value. 2. Scan two numeric bar codes from Numeric Bar Codes beginning on page 5-96. Single digit numbers must have a leading zero. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.
<FN3>305182021E DECODE UPC/EAN SUPPLEMENTAL REDUNDANCY
5-65
Page 106
LS 6800 Product Reference Guide
Linear Code Type Security Level Note: Does not apply to Code 128 The LS 6800 offers four levels of decode security for linear code types (e.g. Code 39, Interleaved 2 of 5). Higher security levels are selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases. Select the security level appropriate for your bar code quality.
Linear Security Level 1 The following code types must be successfully read twice before being decoded: Code Type
Length
Codabar
All
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Linear Security Level 2 All supported code types must be successfully read twice before being decoded.
Linear Security Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:
5-66
Code Type
Length
MSI Plessey
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Codabar
8 or less
Page 107
Programming the LS 6800
Linear Code Type Security Level Linear Security Level 4 All supported code types must be successfully read three times before being decoded.
<FN3>2051501
LINEAR SECURITY LEVEL 4
<FN3>2051503
LINEAR SECURITY LEVEL 3
<FN3>2051504
LINEAR SECURITY LEVEL 1
LINEAR SECURITY LEVEL 2 <FN3>2051502
5-67
Page 108
LS 6800 Product Reference Guide
Bi-directional Redundancy This parameter is only valid when a Linear Code Type Security Level has been enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.
<FN3>1040311 ENABLE BI-DIRECTIONAL REDUNDANCY
DISABLE BI-DIRECTIONAL REDUNDANCY <FN3>1040310
5-68
Page 109
Programming the LS 6800
UPC/EAN Security Level The LS 6800 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
UPC/EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.
UPC/EAN Security Level 1 As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.
UPC/EAN Security Level 2 If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.
UPC/EAN Security Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.
5-69
Page 110
LS 6800 Product Reference Guide
UPC/EAN Security Level (Cont’d)
<FN3>2051100
UPC/EAN SECURITY LEVEL 2
UPC/EAN SECURITY LEVEL 1 <FN3>2051101
5-70
<FN3>2051103
UPC/EAN SECURITY LEVEL 3
<FN3>2051102
UPC/EAN SECURITY LEVEL 0