The text of a manual · part 12 of 25
LS 6800 Product Reference Guide, pages 111 to 120
Pages 111 to 120 of 249
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Symbol LS-6804
Page 111
Programming the LS 6800
RS-232C Options Note: If using a Synapse Cable, consult the Synapse Interface Guide. In Single Port mode, the host device is connected to the HOST port.
RS-232C Host Types This parameter selects an RS-232C host interface option. When you select a specific host, this automatically sets RS-232C parameters to those of that host (see Table 5-4 and Table 5-5).
Table 5-4. Standard RS-232, Nixdorf Host Types Parameter
Std. RS-232
Nixdorf Mode A
Nixdorf Beetle
Xmit Code ID
No
Yes
Yes
Data Trans. Error
Data
Data/Suffix
Data/Suffix
Suffix
None
CR(1013)
CR(1013)
Baud Rate
9600
9600
9600
Parity
None
Odd
Odd
H/W Handshaking
None
None
RTS/CTS Opt. 3
S/W Handshaking
None
None
None
Serial Resp. T/O
2.0 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
Beep on <Bel>
Disabled
Disabled
Disabled
RTS Line State
Low Always
Low Always
Low Always
Special Notes
None
None
Output 0x60 for all CR except last one
5-71
Page 112
LS 6800 Product Reference Guide
RS-232C Host Types (Cont’d) Table 5-5. Fujitsu, ICL, PDT 3300 Host Types
5-72
Parameter
Fujitsu
ICL
PDT 3300
Xmit Code ID
Yes
Yes
Yes
Data Trans. Error
Data/Suffix
Data/Suffix
STX/Data/ETX/ LRC
Suffix
CR(1013)
CR(1013)
None
Baud Rate
9600
9600
19200
Parity
None
Even
Even
H/W Handshaking
None
RTS/CTS Opt. 3
RTS/CTS
S/W Handshaking
None
None
ACK/NAK
Serial Resp. T/O
2.0 Sec.
9.9 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
ASCII Format
8-Bit
8-Bit
7-Bit
Beep on <Bel>
Disabled
Disabled
Disabled
RTS Line State
Low Always
High Always
Low Always
Special Notes
None
None
None
Page 113
Programming the LS 6800
RS-232C Host Types (Cont’d)
<FN3>2050A37
NIXDORF RS-232C
<FN3>2050A89
ICL RS-232C
<FN3> 2050A8A
STANDARD RS-232C
FUJITSU RS-232C <FN3>2050A8B
5-73
Page 114
LS 6800 Product Reference Guide
RS-232C Host Types (Cont’d)
<FN3>2050A8C BEETLE RS-232C
5-74
Page 115
Programming the LS 6800
Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's respective baud rate settings should match the data rate settings of the host and auxiliary devices. If not, data may not reach the devices or may reach them in distorted form. Set the baud rate for RS-232C transmission.
<FN3>2090100
600
<FN3>2090101
300
<FN3>2090102
110
1200 <FN3>2090103
5-75
Page 116
LS 6800 Product Reference Guide
Baud Rate (Cont’d)
<FN3>2090104
9600
19200 <FN3>2090107
5-76
<FN3>2090105
4800
<FN3>2090106
2400
Page 117
Programming the LS 6800
Baud Rate (Cont’d)
<FN3>2090108 38400
5-77
Page 118
LS 6800 Product Reference Guide
Parity A parity check bit is the most significant bit of each ASCII coded character and is helpful in detecting transmission errors. If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit has a value 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. If MARK is selected, the parity bit is always 1, while if SPACE is selected, the parity bit is always 0. Select the parity type according to host requirements.
<FN3>2090300
MARK
EVEN <FN3>2090301
5-78
<FN3>2090303
SPACE
<FN3>2090302
ODD
Page 119
Programming the LS 6800
Parity (Cont’d)
<FN3>2090304 NONE
5-79
Page 120
LS 6800 Product Reference Guide
Check Parity Select whether or not the parity of received characters is checked. The type of parity used is selectable through the PARITY parameter. Select whether or not to check parity for RS-232C transmissions.
<FN3>1080011 CHECK PARITY
DO NOT CHECK PARITY <FN3>1080010
5-80