Page 111

Programming the LS 6800

RS-232C Options Note: If using a Synapse Cable, consult the Synapse Interface Guide. In Single Port mode, the host device is connected to the HOST port.

RS-232C Host Types This parameter selects an RS-232C host interface option. When you select a specific host, this automatically sets RS-232C parameters to those of that host (see Table 5-4 and Table 5-5).

Table 5-4. Standard RS-232, Nixdorf Host Types Parameter

Std. RS-232

Nixdorf Mode A

Nixdorf Beetle

Xmit Code ID

No

Yes

Yes

Data Trans. Error

Data

Data/Suffix

Data/Suffix

Suffix

None

CR(1013)

CR(1013)

Baud Rate

9600

9600

9600

Parity

None

Odd

Odd

H/W Handshaking

None

None

RTS/CTS Opt. 3

S/W Handshaking

None

None

None

Serial Resp. T/O

2.0 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

Beep on <Bel>

Disabled

Disabled

Disabled

RTS Line State

Low Always

Low Always

Low Always

Special Notes

None

None

Output 0x60 for all CR except last one

5-71

Page 112

LS 6800 Product Reference Guide

RS-232C Host Types (Cont’d) Table 5-5. Fujitsu, ICL, PDT 3300 Host Types

5-72

Parameter

Fujitsu

ICL

PDT 3300

Xmit Code ID

Yes

Yes

Yes

Data Trans. Error

Data/Suffix

Data/Suffix

STX/Data/ETX/ LRC

Suffix

CR(1013)

CR(1013)

None

Baud Rate

9600

9600

19200

Parity

None

Even

Even

H/W Handshaking

None

RTS/CTS Opt. 3

RTS/CTS

S/W Handshaking

None

None

ACK/NAK

Serial Resp. T/O

2.0 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

ASCII Format

8-Bit

8-Bit

7-Bit

Beep on <Bel>

Disabled

Disabled

Disabled

RTS Line State

Low Always

High Always

Low Always

Special Notes

None

None

None

Page 113

Programming the LS 6800

RS-232C Host Types (Cont’d)

<FN3>2050A37

NIXDORF RS-232C

<FN3>2050A89

ICL RS-232C

<FN3> 2050A8A

STANDARD RS-232C

FUJITSU RS-232C <FN3>2050A8B

5-73

Page 114

LS 6800 Product Reference Guide

RS-232C Host Types (Cont’d)

<FN3>2050A8C BEETLE RS-232C

5-74

Page 115

Programming the LS 6800

Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's respective baud rate settings should match the data rate settings of the host and auxiliary devices. If not, data may not reach the devices or may reach them in distorted form. Set the baud rate for RS-232C transmission.

<FN3>2090100

600

<FN3>2090101

300

<FN3>2090102

110

1200 <FN3>2090103

5-75

Page 116

LS 6800 Product Reference Guide

Baud Rate (Cont’d)

<FN3>2090104

9600

19200 <FN3>2090107

5-76

<FN3>2090105

4800

<FN3>2090106

2400

Page 117

Programming the LS 6800

Baud Rate (Cont’d)

<FN3>2090108 38400

5-77

Page 118

LS 6800 Product Reference Guide

Parity A parity check bit is the most significant bit of each ASCII coded character and is helpful in detecting transmission errors. If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit has a value 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. If MARK is selected, the parity bit is always 1, while if SPACE is selected, the parity bit is always 0. Select the parity type according to host requirements.

<FN3>2090300

MARK

EVEN <FN3>2090301

5-78

<FN3>2090303

SPACE

<FN3>2090302

ODD

Page 119

Programming the LS 6800

Parity (Cont’d)

<FN3>2090304 NONE

5-79

Page 120

LS 6800 Product Reference Guide

Check Parity Select whether or not the parity of received characters is checked. The type of parity used is selectable through the PARITY parameter. Select whether or not to check parity for RS-232C transmissions.

<FN3>1080011 CHECK PARITY

DO NOT CHECK PARITY <FN3>1080010

5-80