Page 91

Programming the LS 6800

Scan Data Transmission Format The scan data format options listed below can be selected by the user. Standard: Option 1: Option 2: Option 3:

<data> <data> <SUFFIX> <PREFIX> <data> <SUFFIX> <PREFIX> <data>

<data> = scanned bar code data <PREFIX> and <SUFFIX> as selected by the user. To select a scan data transmission format: 1. Scan the SCAN OPTIONS bar code. 2. Scan the bar code corresponding to the desired converted data format. 3. Scan ENTER. 4. If you make a mistake, scan CANCEL on page 5-98. Note: RS-232C hosts treat the extended keypad default suffix (7013) as ASCII data.

5-51

Page 92

LS 6800 Product Reference Guide

Scan Data Transmission Format (Cont’d)

<FN3>7B1210

<PREFIX> <DATA> <SUFFIX>

DATA AS IS <FN3>6A110

5-52

<FN3>6A13071

<DATA> <SUFFIX>

<FN3>6A1572071

SCAN OPTIONS

Page 93

Programming the LS 6800

Scan Data Transmission Format (Cont’d)

<FN3>4 ENTER

<FN3>6A13720

<PREFIX> <DATA>

CANCEL <FN3>6Q

5-53

Page 94

LS 6800 Product Reference Guide

Scanning Options Beep After Good Decode Determine if the scanner’s beeper sounds during normal scanning. In most cases the scanner operates with the beeper enabled. The beeper always operates during parameter menu scanning and indicates error conditions. See Beeper Definitions on page 3-9. Select whether or not to beep after a successful decode. If you select Beep After Good Decode, set the beeper tone or frequency.

<FN3>1040021 BEEP AFTER GOOD DECODE

DO NOT BEEP AFTER GOOD DECODE <FN3>1040020

5-54

Page 95

Programming the LS 6800

Beeper Tone/Frequency This parameter sets the decode beep frequency/tone, low, medium, or high.

<FN3>2050E02 LOW FREQUENCY

<FN3>2050E01

MEDIUM FREQUENCY

HIGH FREQUENCY <FN3>2050E00

5-55

Page 96

LS 6800 Product Reference Guide

Decode Attempt Duration This sets the maximum time decode processing continues during a scan attempt. This is programmable in 0.1 second increments from 0.1 to 9.9 seconds. The recommended interval is between 1.0 and 5.0 seconds. If DECODE ATTEMPT DURATION INFINITE is selected, no timeout occurs; the scanner continues to attempt to decode. 1. Scan a bar code below. 2. If the first bar code was scanned, scan two bar codes from Numeric Bar Codes beginning on page 5-96 which correspond to the desired interval, in 0.1 second increments. 3. If you make an error, or wish to change your selection, scan CANCEL on page 5-98.

<FN3>3050020163 DECODE ATTEMPT DURATION

DECODE ATTEMPT DURATION INFINITE <FN3>20500FF

5-56

Page 97

Programming the LS 6800

Trigger Modes This parameter controls scanner triggering. The following options are available: t t t t

In Level trigger mode, a trigger pull (external hardware or scanner) activates the laser and decode processing. The laser remains on and decode processing continues until a trigger release, a valid decode, or the Decode Attempt Timeout is reached. In Pulse trigger mode, a trigger pull (external hardware or scanner) activates the laser and decode processing. The laser remains on and decode processing continues until a valid decode or the Decode Attempt Timeout is reached. Blinking Laser mode is an internal trigger mode that cycles the scanning laser at approximately a 50% duty cycle after no decode attempts have occurred for 30 seconds. This extends laser life. Continuous mode is an internal trigger mode that operates the scanner at a 100% duty cycle. The scanner continuously attempts to decode a bar code even if none are present. This mode is suited for time-critical applications where bar codes move past the scanner.

5-57

Page 98

LS 6800 Product Reference Guide

Trigger Modes (Cont’d) Select the preferred trigger mode.

<FN3>2050200

PULSE

CONTINUOUS LASER MODE <FN3>2050204

5-58

<FN3>2050207

BLINKING LASER MODE

<FN3>2050202

LEVEL

Page 99

Programming the LS 6800

Scanning Modes This parameter is used to select the preferred scanning mode. See LS 6800 Scanning Mode Options on page 3-1 for descriptions of these modes. Select a scanning mode.

<FN3>2050901

SLAB ONLY RASTER

<FN3>2050903

PROGRAMMABLE RASTER

<FN3>2050904

SMART RASTER

ALWAYS RASTER <FN3>2050902

5-59

Page 100

LS 6800 Product Reference Guide

Scanning Modes (Cont’d)

<FN3>2050905 LINE ONLY PATTERN

5-60