Page 111
LS 6000 Series Product Reference Guide
I 2 of 5 Check Digit Verification (Cont’d)
USS CHECK DIGIT
OPCC CHECK DIGIT
5-78
Page 112
Programming the LS 6000
Transmit I 2 of 5 Check Digit Scan a bar code below to transmit the data with or without the check digit.
TRANSMIT I 2 of 5 CHECK DIGIT (ENABLE)
DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE)
5-79
Page 113
LS 6000 Series Product Reference Guide
Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
CONVERT I 2 of 5 to EAN-13 (ENABLE)
DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE)
5-80
Page 114
Programming the LS 6000
Codabar Options Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below.
ENABLE CODABAR
DISABLE CODABAR
5-81
Page 115
LS 6000 Series Product Reference Guide
Set Lengths for Codabar Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. It also includes any start or stop characters. Scan the appropriate bar code to select one of the following options.
One Discrete Length This option allows you to decode only those codes containing a selected length. For example, if you select Codabar One Discrete Length, then scan 1, 4, the only Codabar symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.
CODABAR - ONE DISCRETE LENGTH
5-82
Page 116
Programming the LS 6000
Two Discrete Lengths This option allows you to decode only those codes containing two selected lengths. For example, if you select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, the only Codabar symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.
CODABAR - TWO DISCRETE LENGTHS
Length Within Range This option allows you to decode a code type within a specified range. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.
CODABAR - LENGTH WITHIN RANGE
5-83
Page 117
LS 6000 Series Product Reference Guide
Any Length Scanning this option allows you to decode Codabar symbols containing any number of characters.
CODABAR - ANY LENGTH
5-84
Page 118
Programming the LS 6000
CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters.
ENABLE CLSI EDITING
DISABLE CLSI EDITING
5-85
Page 119
LS 6000 Series Product Reference Guide
NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.
ENABLE NOTIS EDITING
DISABLE NOTIS EDITING
5-86
Page 120
Programming the LS 6000
Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single character prefix already selected, the code ID character is inserted between the prefix and the decoded symbol. The user may select no code ID character, a Symbol Code ID character, or an AIM Code ID character. The Symbol Code ID characters are listed below; see AIM Code Identifiers in Appendix A. A = UPC-A, UPC-E, EAN-8, EAN-13 B = Code 39 C = Codabar D = Code 128 F = Interleaved 2 of 5 K = UCC/EAN-128 L = Bookland EAN
SYMBOL CODE ID CHARACTER
5-87