Page 101

LS 6000 Series Product Reference Guide

Transmit Code 39 Check Digit Scan a bar code below to transmit the data with or without the check digit.

TRANSMIT CODE 39 CHECK DIGIT (ENABLE)

DO NOT TRANSMIT CODE 39 CHECK DIGIT (DISABLE)

5-68

Page 102

Programming the LS 6000

Code 39 Decode Performance This option offers three levels of decode performance (aggressiveness) for Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation, which is useful if you are scanning very long and/or truncated bar codes. Increased levels reduce decode security. If you enable this option, you may select a decode performance level from the next page. Note: This option only works with Code 39 One Discrete Length.

ENABLE CODE 39 DECODE PERFORMANCE

DISABLE CODE 39 DECODE PERFORMANCE

5-69

Page 103

LS 6000 Series Product Reference Guide

Code 39 Decode Performance (Cont’d) If Decode Performance is enabled, select a level below.

CODE 39 DECODE PERFORMANCE LEVEL 1

CODE 39 DECODE PERFORMANCE LEVEL 2

CODE 39 DECODE PERFORMANCE LEVEL 3

5-70

Page 104

Programming the LS 6000

Enable/Disable Code 39 Full ASCII To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent of ABC ENTER. Refer to Table A-4 in Appendix A. The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.

5-71

Page 105

LS 6000 Series Product Reference Guide

Enable/Disable Code 39 Full ASCII (Cont’d)

ENABLE CODE 39 FULL ASCII

DISABLE CODE 39 FULL ASCII

5-72

Page 106

Programming the LS 6000

Interleaved 2 of 5 Options Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below.

ENABLE INTERLEAVED 2 OF 5

DISABLE INTERLEAVED 2 OF 5

5-73

Page 107

LS 6000 Series Product Reference Guide

Set Lengths for Interleaved 2 of 5 Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. Scan the appropriate bar code to select one of the following options.

One Discrete Length This option allows you to decode only those codes containing a selected length. For example, if you select I 2 of 5 One Discrete Length, then scan 1, 4, the only I 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.

I 2 of 5 - ONE DISCRETE LENGTH

5-74

Page 108

Programming the LS 6000

Two Discrete Lengths This option allows you to decode only those codes containing two selected lengths. For example, if you select I 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only I 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.

I 2 of 5 - TWO DISCRETE LENGTHS

Length Within Range This option allows you to decode a code type within a specified range. For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-117. If you make an error or wish to change your selection, scan CANCEL on page 5-122.

I 2 of 5 - LENGTH WITHIN RANGE

5-75

Page 109

LS 6000 Series Product Reference Guide

Any Length Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters. Note: Selecting the Any Length option may lead to misdecodes for I 2 of 5 codes.

I 2 of 5 - ANY LENGTH

5-76

Page 110

Programming the LS 6000

I 2 of 5 Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm, either Uniform Symbology Specification (USS), or Optical Product Code Council (OPCC).

DISABLE

5-77