The text of a manual · part 7 of 24
LS 6000i Series Product Reference Guide: Chapter 4 Maintenance and Specifications
Pages 36 to 41 of 205, from LS 6000i Series Product Reference Guide
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-6005 and Symbol LS-6004
Page 36
Chapter 4 Maintenance and Specifications Maintaining Your Scanner The only maintenance your LS 6000i scanner requires is an occasional cleaning of the scan window to remove fingerprints or other debris. Since the LS 6000i scan window is a high performance optical element, care should be given during cleaning. Use only a mild soap and water solution applied to a soft, clean cloth (NOT directly to the scan window). Buff the scan window gently with the cloth to remove any streaking.
4-1
Page 37
LS 6000i Series Product Reference Guide
Scan Zone When an omnidirectional mode is selected, the LS 6000i scanner emits a 20-line scan pattern designed to allow you to read bar codes, even very long and narrow ones, easily from almost any angle. The scan pattern is projected directly out of the scan window creating the three dimensional “scan zone” shown below. To read a bar code, present the bar code within this pattern. 10” (100% UPC)
Note: This scan zone is based on the use of a 100% UPC/EAN bar code. The zone will vary for different code types and densities.
Figure 4-1. LS 6000i Scan Zone 4-2
Page 38
Maintenance and Specifications
Technical Specifications Table 4-1. Technical Specifications Item
Description
Power Requirements
5.2 VDC +/- 5% @400mA
Omnidirectional Scan Pattern
20-line, 5-direction dynamic cross pattern; 1200 scans per second
Single-Line Scan Pattern
60 scans per second
Decode Depth of Field
Maximum working distance is 10 in. (25.4 cm) on 100% UPC/EAN symbol
Decode Capability
UPC/EAN/JAN (with and without supplementals), Code 128, Code 39, Interleaved 2 of 5, Codabar, UCC/EAN 128, Bookland EAN, RSS-14, RSS Limited, RSS Expanded
Durability
4 ft. (1.2 meter) drops to concrete
Operating Temperature
32° to 104°F (0° to 40°C)
Storage Temperature
-40° to 140°F (-40° to 60°C)
Humidity
5% to 95% non-condensing
4-3
Page 39
LS 6000i Series Product Reference Guide
Table 4-1. Technical Specifications (Continued) Item
Description
Ambient Light
Immune to normal artificial indoor and natural outdoor (direct sunlight) lighting conditions Flourescent, incandescent, mercury vapor, sodium vapor: 450 ft.-candles Sunlight: 9000 ft.-candles
Weight
7.4 oz. (210 gm)
Height
7.64 in. (194 mm)
Width
2.72 in. (69 mm)
Depth
3.19 in. (81 mm)
4-4
Page 40
Maintenance and Specifications
Troubleshooting Table 4-2. Troubleshooting Problem
Solution
The scanner is not Refer to Chapter 2, Setup to verify that decoding and the your scanner is properly connected. green LED is not lit? The scanner is not Check the bar code to make sure it is not decoding and the defaced. green LED is lit? Verify that the code type you are scanning is enabled. Verify that the symbol length for that code type is correct. Try scanning similar bar codes of the same code type. Make sure the Beep After Good Decode parameter is enabled. Make sure a flash download cable is not being used.
4-5
Page 41
LS 6000i Series Product Reference Guide
Table 4-2. Troubleshooting (Continued) Problem
Solution
The scanner is not Make sure the scanner is connected to transmitting to the the terminal. host terminal? Make sure the host terminal is properly configured. Be sure that you've scanned the proper host type. If you’re using RS-232, be sure all RS232 parameters (e.g., baud rate, data bits, handshaking) are set properly to communicate with the host.
4-6