Page 36

Chapter 4 Maintenance and Specifications Maintaining Your Scanner The only maintenance your LS 6000i scanner requires is an occasional cleaning of the scan window to remove fingerprints or other debris. Since the LS 6000i scan window is a high performance optical element, care should be given during cleaning. Use only a mild soap and water solution applied to a soft, clean cloth (NOT directly to the scan window). Buff the scan window gently with the cloth to remove any streaking.

4-1

Page 37

LS 6000i Series Product Reference Guide

Scan Zone When an omnidirectional mode is selected, the LS 6000i scanner emits a 20-line scan pattern designed to allow you to read bar codes, even very long and narrow ones, easily from almost any angle. The scan pattern is projected directly out of the scan window creating the three dimensional “scan zone” shown below. To read a bar code, present the bar code within this pattern. 10” (100% UPC)

Note: This scan zone is based on the use of a 100% UPC/EAN bar code. The zone will vary for different code types and densities.

Figure 4-1. LS 6000i Scan Zone 4-2

Page 38

Maintenance and Specifications

Technical Specifications Table 4-1. Technical Specifications Item

Description

Power Requirements

5.2 VDC +/- 5% @400mA

Omnidirectional Scan Pattern

20-line, 5-direction dynamic cross pattern; 1200 scans per second

Single-Line Scan Pattern

60 scans per second

Decode Depth of Field

Maximum working distance is 10 in. (25.4 cm) on 100% UPC/EAN symbol

Decode Capability

UPC/EAN/JAN (with and without supplementals), Code 128, Code 39, Interleaved 2 of 5, Codabar, UCC/EAN 128, Bookland EAN, RSS-14, RSS Limited, RSS Expanded

Durability

4 ft. (1.2 meter) drops to concrete

Operating Temperature

32° to 104°F (0° to 40°C)

Storage Temperature

-40° to 140°F (-40° to 60°C)

Humidity

5% to 95% non-condensing

4-3

Page 39

LS 6000i Series Product Reference Guide

Table 4-1. Technical Specifications (Continued) Item

Description

Ambient Light

Immune to normal artificial indoor and natural outdoor (direct sunlight) lighting conditions Flourescent, incandescent, mercury vapor, sodium vapor: 450 ft.-candles Sunlight: 9000 ft.-candles

Weight

7.4 oz. (210 gm)

Height

7.64 in. (194 mm)

Width

2.72 in. (69 mm)

Depth

3.19 in. (81 mm)

4-4

Page 40

Maintenance and Specifications

Troubleshooting Table 4-2. Troubleshooting Problem

Solution

The scanner is not Refer to Chapter 2, Setup to verify that decoding and the your scanner is properly connected. green LED is not lit? The scanner is not Check the bar code to make sure it is not decoding and the defaced. green LED is lit? Verify that the code type you are scanning is enabled. Verify that the symbol length for that code type is correct. Try scanning similar bar codes of the same code type. Make sure the Beep After Good Decode parameter is enabled. Make sure a flash download cable is not being used.

4-5

Page 41

LS 6000i Series Product Reference Guide

Table 4-2. Troubleshooting (Continued) Problem

Solution

The scanner is not Make sure the scanner is connected to transmitting to the the terminal. host terminal? Make sure the host terminal is properly configured. Be sure that you've scanned the proper host type. If you’re using RS-232, be sure all RS232 parameters (e.g., baud rate, data bits, handshaking) are set properly to communicate with the host.