Page 28

Chapter 3 Scanning Scanning In Hand-Held Mode The LS 6000i may be placed on the counter-top or in the Desk Mount Stand (optional). The scanner operates in one of the following three trigger modes, programmable by the bar codes in Trigger Mode on page 5-54: •

Combination Mode (Default) The omnidirectional scan pattern is always on and ready to decode. When the trigger is pulled, the scanner emits a single scan line to decode, then reverts back to omnidirectional constanton. This mode is only for hand-held use.

•

Triggered Omnidirectional Mode An omnidirectional scan pattern activates upon trigger pull.

3-1

Page 29

LS 6000i Series Product Reference Guide

•

Triggered Single Scan Line Mode A single scan line appears upon trigger pull.

To scan in hand-held mode, pick up the scanner and hold it within the scanning range for the bar code. If the scanner is in the constant-on mode, it decodes the bar code automatically. If the scanner is in a triggered mode, pull the trigger to activate the scan pattern and decode the bar code.

Figure 3-1. Holding the Scanner

3-2

Page 30

Scanning

Scanning in Hands-Free (Presentation) Mode To place the LS 6000i scanner in the optional HandsFree Presentation Stand, slide the rubber “chin” support on the scanner into the notch in the stand until the scanner is firmly seated. The scanner emits a constanton omnidirectional pattern. To scan a bar code, bring the bar code anywhere within 10 in. (25.4 cm) of the scanner window for a successful decode. Bar codes can either be directed in toward the nose of the scanner (“presentation” scanning) or from side to side in a sweeping motion (“swipe” scanning).

Inserting LS 6000i into Stand

Scanning in the Stand

Figure 3-2. Inserting the Scanner into Stand and Scanning

3-3

Page 31

LS 6000i Series Product Reference Guide

When the LS 6000i is removed from the Presentation Stand, the scanner operates in the programmed trigger mode (see Scanning In Hand-Held Mode on page 3-1 for trigger mode descriptions).

3-4

Page 32

Scanning

Selecting Beeper Volume The LS 6000i emits a short beep when it successfully reads a bar code. There are three volume settings for this decode beep. To change the setting, scan the programming bar codes for Beeper Volume on page 557. To adjust the frequency (tone) of the scanner’s beeper, see Beeper Frequency on page 5-59.

3-5

Page 33

LS 6000i Series Product Reference Guide

Beeper Indications The beeper indicates the scanner’s status as follows: Table 3-1. Beeper Indications Beeper

Indication

3 Beeps

Power up (or reset) has occurred.

1 Beep

A bar code has been successfully decoded.

4 Beeps

A transmission error has occurred. Bar code data was not received by the host.

Fast warble

A programming parameter was entered successfully.

3-6

Page 34

Scanning

LED Indications The green LED located on top of the scanner indicates the operational status of the scanner. These LED indications are defined below: Table 3-2. LED Indications LED

Indication

Off

No power is applied to the scanner.

On steady

The scanner is on and “ready to scan,” or a flash download cable is attached.

Momentary flash off

A bar code has been successfully decoded.

Fast double-blinking

The scanner is in a programming sequence.

Fast sequential flashing

A scanner malfunction has occurred.

Slow steady blinking

The scanner is in flash program mode.

3-7

Page 35

LS 6000i Series Product Reference Guide